Fire Extinguisher and Fire Hose Maintenance Services State and local opportunity open County of Orange IFB-080-3157202-EL Posted: 2026-11-13T19:26:31.695Z Response deadline: 2026-12-08T22:00:00.000Z The County of Orange, OC Public Works , (hereinafter referred to as County) is requesting competitive bids from qualified vendors (hereinafter referred to as Bidder) for Fire Extinguisher and Fire Hose Maintenance Services . The County has attempted to provide all information available. It is the responsibility of each Bidder to review, evaluate, and, where necessary, request any clarification prior to submission of a bid. The awarded Contract, (hereinafter referred to as Contract) will be between the County and awarded Bidder, (hereinafter referred to as Contractor) in accordance with the model contract terms, conditions and scope of work. This is a fully electronic solicitation – only electronic bids submitted through the County’s online bidding system will be allowed; no other form of bid submittals will be accepted. Prior to submitting a bid, Bidders are advised to carefully read the instructions below, including the model contract and any solicitation attachments and/or exhibits. For assistance on uploading proposals via County’s eProcurement Portal, please contact procurement-support@opengov.com or https://help.procurement.opengov.com/en/ . All questions or requests for interpretations must be received within this solicitation's Question & Answer section as specified in the solicitation. Respondents are not to contact other County personnel with any questions or clarifications concerning this solicitation. Fire Extinguishers - Pressurized Water Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. 2.5 Gal. Extinguisher Off-site hydrostatic testing when required Fire Extinguishers - Dry Chemical (Store-Pressure Type) Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. 2.5 lb. Extinguisher 5 lb. Extinguisher 6 lb. Extinguisher 10 lb. Extinguisher 20 lb. Extinguisher Off-site hydrostatic testing when required (Per Title 19, once every 12 years) Fire Extinguishers - Cartridge-Operated Extinguisher Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. 5 lb. Extinguisher 6 lb. Extinguisher 10 lb. Extinguisher 20 lb. Extinguisher 30 lb. Extinguisher Discharge Cartridge, for recharged extinguisher only Off-site hydrostatic testing when required (Per Title 19, once every 12 years) Fire Extinguishers - K Class Fire Extinguishers Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. K Class Fire Extinguisher Service K Class Fire Extinguisher 5-year hydrostatic testing If used or replacement chemical for 5-year hydrostatic testing 6-Liter Hydrostatic Testing when required (Per title 19 once every 5 years) Fire Extinguishers - Replacement Dry Chemical Powder Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. Sodium Bicarbonate (BC) Potassium Bicarbonate (PK) Monoammonium Phosphate (ABC) Sodium Chloride (D) Fire Extinguishers - Carbon Dioxide Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. 5 lb. Extinguisher 6 lb. Extinguisher 10 lb. Extinguisher 15 lb. Extinguisher 20 lb. Extinguisher Off-site hydrostatic testing when required (Per Title 19, once every 5 years) Off-site teardown and rebuild Replacement Carbon Dioxide Fire Extinguishers - Halon Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. 2.5 lb. Extinguisher 5 lb. Extinguisher 6 lb. Extinguisher 9 lb. Extinguisher 13 or 14 lb. Extinguisher 17 or 20 lb. Extinguisher Off-site hydrostatic testing when required (Per title, once every 12 years) Off-site “6 year” maintenance Replacement Halon 1211 Fire Extinguishers - Purple K Extinguishers Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. Purple K Annual Certification Purple K Six Year Break Down (wheeled unit) Recharge / Refill of Purple K (wheeled unit) Hydrostatic Testing (any size unit) (Per title 19, once every 12 years) Recharge / Refill of Hydrostatic Tested (non-wheeled unit) Replacement Purple K Chemical Fire Extinguishers - Halotron Extinguishers Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections, re-charges, refills, re-tag and replace necessary parts for fire extinguishers. Warranty for Services shall be a minimum of one (1) year (365 days) from the date of acceptance. Halotron Annual Certification Halotron Six Year Maintenance Hydrostatic Testing (any size unit) (Per title 19, once every 12 years) Replacement of Chemical Transfer of Chemicals (clean agent) Services/Inspections - Fire Hoses Contractor shall provide all labor, parts/materials, special equipment and any associated costs to perform Services, inspections and replace necessary parts for hoses. Warranty for Services shall be a minimum of one (1) year. Annual Fire Hose Service Fire Hoses Hydro-static tested & re-racked (5-year testing on new hoses/ 3-year testing thereafter) Products - Fire Extinguishers Contractor shall provide the following items for purchase on an as-needed basis at the price quoted below throughout the term of the contract. K Class Fire Extinguisher 2.5 Gallon ABC Fire Extinguisher 2.5 Gallon Water Fire Extinguisher 20 lb. Water Fire Extinguisher 2.5 lb. ABC Fire Extinguisher (Ansul brand) 5 lb. ABC Fire Extinguisher 10 lb. ABC Fire Extinguisher 20 lb. ABC Fire Extinguisher Products - Halotron Contractor shall provide the following items for purchase on an as-needed basis at the price quoted below throughout the term of the contract. New 1.4 lb. Halotron New 2.5 lb. Halotron New 5.0 lb. Halotron New 11 lb. Halotron New 15 lb. Halotron Products - Hoses/Racks Contractor shall provide the following items for purchase on an as-needed basis at the price quoted below throughout the term of the contract. 1.5” x 50’ rack and reel hose .5” x 75’ rack and reel hose 1.5” x 100’ rack and reel hose 1.5” x 50’ single jacket rubber lined hose 1.5” x 75’ single jacket rubber lined hose 1.5” x 100’ single jacket rubber lined hose Products - Carbon Dioxide Contractor shall provide the following items for purchase on an as-needed basis at the price quoted below throughout the term of the contract. CO2 10 lbs. Miscellaneous Parts/Materials - Percentage Discount off Manufacturer's Catalog Contractor shall furnish all repair parts and other materials required to complete Services. Contractor shall provide a quotation and obtain County approval for all repair parts and materials before ordering. Quote for repairs shall include estimated time for completion of such work. Percentage Discount Allowed to the County Miscellaneous Parts/Materials - Additional, Urgent or Emergency Work Contractor shall furnish all repair parts and other materials required to complete Services. Contractor shall provide a quotation and obtain County approval for all repair parts and materials before ordering. Quote for repairs shall include estimated time for completion of such work. Hourly Rate – for additional work performed during Regular Business Hours Hourly Rate – for additional urgent or emergency work performed outside of Regular Business Hours Scope of Work Scope of Work Contractor shall provide Fire Extinguishers, Fire Hoses and Related Services to various departments/agencies located throughout the County of Orange, including those not listed herein. Usage of this Contract will be on an as needed basis. Usage is not guaranteed. Contractor Requirements Contractor shall: Possess and maintain all applicable federal, state, and local permits, licenses and approvals necessary to provide goods and Services as required in Attachment A, Scope of Services. Any associated fees shall be the responsibility of Contractor. Provide all labor, management, supervision, tools, parts/materials to Service and maintain fire extinguishers and fire hoses in accordance with contract requirements; the California Code of Regulations (CCR); National Fire Protection Association (NFPA) standards and appropriate manufacturer specifications; all applicable technical bulletins, trade, federal, state and local laws, ordinances, rules and regulations, including, but not limited to laws applicable to the Services at the time Services are provided to and accepted by the County. Contractor shall perform maintenance Services and make repairs to return extinguisher and hose reliability. Comply with all applicable local, state, and federal safety requirements at all times when performing work under this Contract for the County. Provide a dedicated Project Manager and/or inside Customer Service Representative knowledgeable of the Contract products, to efficiently answer all County questions/inquiries. Project Manager and/or Customer Service Representative shall be available during Regular Business Hours to assist County with placement of orders, follow-ups, and any other areas requiring assistance within the realm of their responsibility. Contractor must provide a Customer Service point of contact for after-hours and urgent requests. Arrive at the project site as scheduled. All work shall be performed in a skillful and workmanlike manner by Contractor personnel that is trained and licensed appropriately for the work performed. Furnish and maintain a telephone answering system with a 24- hour, seven-day per week service, capable of contacting and dispatching service personnel (“Customer Service”). Report to the County Project Manager or designee upon arrival at County facilities. Upon completion of Services, the Contractor shall return to the County Project Manager or designee for written approval of Services performed. Schedule urgent, but non-emergency, Services within one (1) business day from County request. Contractor must perform work for service call within (3) business days, except as required herein for emergency services, and unless otherwise specified by requesting Department. Shop work (work performed outside of County facilities) is included in this Contract at no additional charge. A comparable loaner will be provided when required, at no charge. When a fire extinguisher, fire hose, and related equipment must be removed from County premises, the County Project Manager or designee must be notified in writing prior to removal. The serial number for removed equipment must be documented upon exit and return. A signed receipt for such equipment must be provided to County Project Manager or designee prior to its removal. Communicate all incomplete Services/maintenance to the County Project Manager or designee and provide an explanation of why Service/maintenance was not completed. Accept full responsibility for security loss or damage to fire extinguisher, fire hose, and related equipment involved while in Contractor’s possession. Contractor shall reimburse the County for any loss or damage to County equipment while in Contractor’s care or custody. Repair of Extinguishers and Associated Equipment: At the direction of and upon written request by County, Contractor shall perform non-emergency and emergency repair services of extinguishers and related equipment. All repairs shall be in accordance with manufacturer’s specifications and industry standards and shall be on an “on-call” basis. Contractor shall accomplish necessary repairs, including replacing parts as required, to correct equipment malfunction(s). Damages to County Property: Contractor shall protect all furnishings and property from damage by its operations. All damage to County owned furnishings, property, and equipment will be repaired or replaced within a reasonable time after notification of such damages. Repairs and/or replacements shall be equal to original furnishings and improvements in all aspects. Damages, repairs, and replacements shall be documented by Contractor and provided to theCounty Project Manager or designee. Non-emergency Repair: Contractor shall be on-site within four (4) hours after having received the County Project Manager’s or designee’s call for repair. Emergency Repair: Contractor shall provide emergency repair coverage twenty-four (24) hours per day, seven (7) days per week, including holidays. Contractor shall be on-site within one (1) hour after having received the County Project Manager’s or designee’s call for repair. All Services shall be subject to the inspection and approval of County either by the County Project Manager or designee prior to acceptance and approval for payment. Contractor staff shall be courteous to the public and County staff utilizing facilities where Contractor is performing work but shall be responsive only to the requests of the County Project Manager or designee. Contractor staff shall direct all inquiries to County Project Manager or designee. Contractor and County Project Manager will identify and inventory all extinguishers and hoses on floor plan. Inventory shall include manufacturer’s name, model and serial number. County Project Manager will maintain updated floor plan and provide Contractor with a copy. Professional Standards: Contractor acknowledges that County locations consist of public-use facilities and recognizes the obligation to ensure Contractor personnel and agents maintain the highest level of professional standards in attire, decorum, and interaction with the public and County personnel. Contractor shall bill in accordance to the rates listed in Attachment B &nd Fire Extinguisher Service Requirements Contractor shall undertake all requirements under this section, inspect, test, service, recharge, certify, and tag all fire extinguishers located at County locations in accordance with manufacturer’s specifications, industry standards, and applicable laws and regulations, and on an “oncall” basis. Contractor will ensure all extinguishers will operate safely and effectively at all times, adhere to NFPA 10, and all other applicable laws and regulations and shall perform the following duties at minimum: Clean extinguisher. Inspect entire unit and identify for signs of dents, rust, corrosion, pitting or other shell damage. Inspect pressure gauge to ensure unit is at proper range and gauge. Confirm that there are no obstructions to access to or visibility of fire extinguisher. Verify test and maintenance dates to determine the need for hydrostatic test, 6-year internal maintenance, or thorough shop check, etc. Weigh extinguisher to ensure correct amount of extinguishing agent. Remove discharge hose/nozzle to inspect for signs of blockage. Remove pull pin to ensure that it can be removed in the event of an actual fire emergency and install new tamper seal. Check handle/lever to ensure smooth operation (not bent). Install or re-install units to ensure proper, permanent location or unit. Check hazard application to ensure fire extinguisher is appropriate for the potential fire hazard. Return extinguisher to proper location after inspection and/or repair. Attach and complete service tag with proper information. Fire extinguisher(s) located on boats may receive increased or adjusted inspections and maintenance due to unstable conditions. Hydrostatic Testing and Six-Year Maintenance: Contractor shall be responsible for replacing all fire extinguishers requiring either a six-year maintenance or hydrostatic testing. Contractor shall perform and certify units due for hydrostatic testing as required and in accordance with Title 8 General Industry Safety Orders Section 6151 (f), State Fire Marshal’s code and Department of Transportation (DOT) requirements. County extinguishers may be taken off site and replaced with a loaner unit of the same or greater capacity for hydrostatic testing. Loaner units shall be provided by the Contractor at no cost to the County. Contractor must submit a list by serial number of all extinguishers that require hydrostatic testing. Inventory: After execution of contract or receiving a floor plan from the County Project Manager or designee if available, Contractor shall perform and submit an updated inventory report of all fire extinguishers and their locations to the County Project Manager or designee at the completion of the service call. A current inventory report shall be prepared and submitted to the County on a quarterly basis upon execution of contract and upon request. Inventory report shall include the following at minimum: Location: Name of site and additional location details specific to unit if multiple units are located at same site (Agency/Department, building, floor, room, etc.). Serial number; Service history; Size; Type; Manufacturer Name; and Date Manufactured. Seals: Lead Wire seals are to be used on all extinguishers located out-of-doors. Plastic seals may be used on extinguishers inside. Warranty: Contractor shall warrant all equipment, parts, and materials for a period of one (1) year (365 days) at minimum or a period equivalent to manufacturer’s warranty, whichever period is longer, from the date of acceptance. Contractor shall furnish and assume responsibility for ensuring qualified staff, equipment, transportation, and all other considerations are consistently sufficient for completion of Services as required by the County. Recharging of Fire Extinguishers All fire extinguishers that are within two years of their required six-year maintenance date or hydrostatic date shall be tested at time of Service. In addition to the tag or label, each fire extinguisher that needs recharging must have a “Verification of Service” collar located around the neck of the container. The collar shall contain a single circular piece of uninterrupted material forming a hole of a size that will not permit the collar assembly to move over the neck of the container unless the valve is completely removed. The collar shall not interfere with the operation of the fire extinguisher. The “Verification of Service” collar shall include the month and year Service was performed, indicated by a perforation, such as is done by a hand punch. Each fire extinguisher shall have a maintenance tag or label securely attached that indicates the month and Source: OpenGov https://procurement.opengov.com/portal/ocgov/projects/316660 Canonical URL: https://govcontractfinder.com/contracts/fire-extinguisher-and-fire-hose-maintenance-services-opengov-108-project-316660