Layer 1 Network and Telecommunications Infrastructure Upgrade State and local opportunity open Pinellas County School District 26-BM-045 Posted: 2026-11-05T19:42:44.526Z Response deadline: 2027-01-04T21:00:00.000Z The Pinellas County School District (District) is soliciting sealed electronic bids in response to Layer 1 Network and Telecommunications Infrastructure Upgrade . Bids are due before 4:00 pm on Monday, January 4, 2027 . Bids may be received up to but not later than, the date and time listed above, via the District e-Procurement Portal located at https://procurement.opengov.com/portal/PCSB . The District e-Procurement Portal Clock is the official clock for the determination of all deadline dates and times. Without exception, responses will not be accepted after the submission deadline regardless of any technical difficulties such as poor internet connections. The Pinellas County School District Purchasing Department strongly recommends completing your response well ahead of the deadline. The Pinellas County School District (District) is soliciting competitive proposals from qualified contractors to furnish all labor, materials, equipment, and services necessary for the upgrade and modernization of Layer 1 network and telecommunications infrastructure throughout schools within the District. This includes, but is not limited to, structured cabling, fiber optic backbone systems, horizontal copper cabling, telecommunications distribution frames and all associated pathways, support components and infrastructure materials. The District is seeking bids for Category 2 Internal Connections, specifically for structured cabling installation for 98 school sites, listed in Exhibit A. This is intended to be a multi-year project spanning (at minimum) April 1 st 2027 through June 30 th 2031. Multiple vendors may be awarded this contract and participation in the project. The work will be conducted in two phases: Phase 1 (fiber optic infrastructure) and Phase 2 (horizontal Category 6/6A Ethernet cabling), as described in Section 2.2. This procurement is dependent on E-Rate Category 2 funding, as described in Section 8.6. A Form 470 for this opportunity has been submitted to USAC, and is available on their website. Pinellas County Schools has partnered with OpenGov Procurement which provides government agencies and their suppliers with a comprehensive and easy to use web-based eProcurement system. Registered suppliers receive automatic notification and transmittal of bid solicitations, and there is no charge to register and subscribe to receive PCS solicitation notifications. Please visit https://procurement.opengov.com/portal/pcsb to register and subscribe. Once you have downloaded bid documents from an OpenGov notification you will automatically receive an e-mail notifying you when any addenda are issued or questions posted have been answered. If you obtain our solicitation documents from any other source, we cannot guarantee that you will automatically receive subsequent notifications of addendums. To assure that you are automatically notified, you must visit the above website and download the bid document. The District will not be responsible if you fail to receive any and all addendums if you obtain the original bid document from another source. The district will give consideration to prices established by the State of Florida Department of Management Services, Division of Purchasing through its contracts and negotiated agreement price schedules. The procurement contact for this solicitation is Barbara Molfetta and can be reached at molfettab@pcsb.org . Submit Electronic Responses via the District e-Procurement Portal: https://procurement.opengov.com/portal/PCSB Scope of Work 2.1 General Scope The Contractor shall provide a complete, fully functional, and tested structured cabling system at each designated school facility. The Contractor is responsible for all materials, equipment, and labor — including all incidental items — necessary to deliver a complete system, whether or not every component is individually itemized in this specification. The scope encompasses all work from the Main Distribution Frame (MDF) through every Intermediate Distribution Frame (IDF) and out to each individual communications jack. The work shall be performed in two phases, as described in Section 2.2. Unless specified by the owner, all existing raceway to be reused inclusive of all flex innerduct runs, cabinets and pull boxes, J Hooks, etc. (reuse all existing racks/cabinets). Some inground conduit paths may be damaged or lack available expansion space. Contractor will need to provide cost for repair/installation, see relevant line items in the Pricing Submittal Form. In certain MDF/IDF locations, additional cable management infrastructure may be needed, see relevant line items in the Pricing Submittal Form. All equipment and materials must be new. Used, re-conditioned or refurbished equipment or materials will not be acceptable. 2.2 Project Phasing The project will be conducted in two separate phases. Each phase is described below, and the subsections of this Section 2 identify the phase in which each scope item falls. Phase 1 — Fiber Optic Infrastructure. Phase 1 consists solely of fiber optic cabling and supporting equipment, components, and materials, together with the associated remediation necessary for the installation; meeting best practices and applicable standards. Phase 1 includes: Fiber optic backbone cabling (OS2 single-mode or OM4 multi-mode) as described in Section 2.3. Please note that the vendor will need to provide Cisco compatible LR transceivers in any event that single-mode fiber is specified or requested. Rack-mounted fiber interconnect cabinets, couplers, connectors, and fiber management, and the remediation of MDF and IDF spaces required to install the fiber in accordance with best practices and standards. Associated pathways, innerduct, conduit, pathway remediation, fire stopping, and any grounding and bonding required for the fiber installation. Labeling, testing, and documentation of the fiber optic plant. Phase 2 — Horizontal Ethernet Cabling. Phase 2 consists of horizontal Category 6 or Category 6A Ethernet cabling and supporting equipment, components, and materials, together with associated network closet remediation. Phase 2 includes: Horizontal Category 6 cabling or Category 6A cabling, as described below in Sections 2.5 through 2.9. Communications outlets, patch panels, patch cords, and associated cable pathways. Remediation of MDF and IDF network closets associated with the horizontal cabling, as described in Section 2.6. Labeling, testing, and documentation of the horizontal cabling. Phase Scheduling. Phase 1 will be performed in Years 1 and 2 (FY 2027-28 and FY 2028-29), and Phase 2 will be performed in Years 3 and 4 (FY 2029-30 and FY 2030-31), at each school in the fiscal year designated in Attachment B for the award scenario selected by the District. Phase 2 work at a school shall not begin until Phase 1 at that school has been completed and accepted in writing by the District, unless the District directs otherwise in writing. General Requirements. Except where this RFP states otherwise, the requirements of this RFP (including testing, documentation, labeling, training, and warranty requirements) apply to each phase in accordance with its scope. 2.3 Fiber Optic Backbone Cabling (Phase 1) The Contractor shall furnish and install all inter-building and intra-building fiber optic cabling as follows: Fiber Types: The fiber optic backbone to be installed may be single-mode (OS2) or multi-mode (OM4). Please note that the District may choose to generally standardize on single-mode fiber, rather than using multi-mode fiber for runs of 400 meters or less. Hybrid fiber optic cable (cable containing both single-mode and multi-mode strands) will not be accepted. Multimode OM4 Fiber: Where multimode fiber is installed, provide tight-buffered, indoor/outdoor plenum-rated, multi-strand 50/125 µm OM4 fiber optic cable for runs of 400 meters or less. Cable shall be VCSEL-optimized and shall exceed ANSI/TIA 568.3-E and IEEE 802.3ae specifications. All fiber strands shall be terminated with LC fusion splice-on connectors. Pull strings shall be installed with all fiber for future use. Single Mode Fiber: Where single mode fiber is installed, provide indoor/outdoor plenum OS2 9/125 µm single mode fiber. Single mode fiber shall be installed for all runs exceeding 400 meters. Proposed single-mode product cut sheets must be submitted for review and approval prior to ordering. Cable shall exceed ANSI/TIA 568.3-E and IEEE 802.3ae specifications. All fiber strands shall be terminated with LC fusion splice-on connectors. Pull strings shall be installed with all fiber for future use. Armored Fiber: Where specified by the District (for example, in exposed or high-risk pathways, crawl spaces, or areas subject to physical damage or rodents), OS2 or OM4 fiber optic cable shall be furnished with interlocking aluminum armor, indoor/outdoor plenum-rated where required, and shall otherwise meet all requirements of this section. The armor shall be bonded and grounded at each end in accordance with the NEC and ANSI/TIA-607-D. Armored cable is priced as a per-foot adder to the corresponding per-foot fiber price, plus armor bonding kits, in the Pricing Submittal Form. Star Configuration: All backbone cables shall run in a star configuration from MDF to each IDF. There shall be no intermediate splicing or bridging between backbone segments. Fiber Counts: As indicated on project drawings. Termination: All fiber strands shall be fusion-splice terminated and landed on rack-mounted fiber interconnect cabinets at both ends. The Contractor shall own fusion splicer equipment. The Owner shall be notified at least 48 hours prior to connector installation and may elect to be present. Fiber Pricing: Per-foot fiber pricing in the Pricing Submittal Form includes furnishing and pulling the cable, pull string and labeling. Each terminated strand end shall be priced under the per-strand-end termination line items, which include the LC fusion splice-on connector, fusion, dust cap, labeling, and bi-directional OLTS/OTDR testing. Fusion splice, fan-out kit and splice enclosure line items are for repair or District-directed use only. Removal of Existing Fiber Cabling: Removal and disposal of existing fiber optic cabling being replaced by the new installation, including abandoned cable as required by the National Electrical Code (NEC Article 800 / 770 as applicable), is included in the per-foot fiber pricing. Removal of cabling not associated with a new installation shall be performed only at the District’s direction under the ‘Demolition of Existing Cabling’ line item, is not E-Rate eligible, and shall be invoiced to the District separately as an ineligible cost. Recommended Fiber Manufacturers: Belden FiberExpress OM4: FD4DxxxP9 / Single-mode: FDSDxxxP9 Corning OM4: xxxT8P-31190-29 / Single-mode: xxxE8P-31131-29 Recommended Connector Manufacturers: Belden FX Fusion: OM4 FT4LC900FS01 / Single-mode FTSLC900FS01 Corning FuseLite: OM4 SOC-LC-900-OM4 / Single-mode SOC-LCU-900-SM Recommended Fiber Interconnect Cabinet Manufacturers: Belden: FiberExpress Ultra Cabinets, FX-FMT Series Leviton: SPBC2 Series 2.4 Excavation and Underground Pathways (Phase 1) Where underground cabling is required, the Contractor shall provide all excavation, backfill, and compaction per industry standards. Jack-and-bore methods are preferred beneath concrete slabs, sidewalks, and similar hardscape. Dewatering shall be provided as necessary. Restoration of all disturbed surfaces, including concrete, asphalt, sidewalks, sod, irrigation and landscaping, to pre-construction condition or better is included in the unit pricing for directional boring, trenching and conduit installation. No separate charges will be accepted for surface restoration. 2.5 Horizontal Copper Cabling (Category 6 and Category 6A) (Phase 2) The Contractor shall furnish and install Category 6 or Category 6A horizontal copper cabling, as specified by the District, from each IDF to all communications outlets throughout each facility, as follows: Cable Type: All horizontal cabling shall be Category 6 or Category 6A U/UTP, plenum-rated where required, and riser-rated in non-plenum spaces. Run Length: Maximum horizontal cable run length shall not exceed 90 meters from the IDF to the furthest workstation. Service Loop: Each cable run shall include five feet of slack service loop coiled above the ceiling directly above each communications outlet drop. Termination Sequence: Cables shall be terminated in sequential order (lowest room number first, Station A first, Ports 1–4 in order) on 48-port patch panels at the IDF end, and on Category 6 or Category 6A data jacks (matching the cable category) at the workstation end. Termination Method: All copper station cables shall be terminated using 110-type insulation displacement connectors (IDC) with T568A pin/pair assignment. Drop Pricing: Drop pricing shall be used for every new or replacement horizontal cable run. Component line items apply only to work that does not constitute a complete drop (repairs, moves/adds/changes, re-termination of existing cable) and require prior District approval. Where a drop line item applies, the District will NOT accept component or hourly pricing for that work. Removal of Existing Copper Cabling: Removal and disposal of existing horizontal copper cabling being replaced by a new drop, including abandoned cable as required by the National Electrical Code (NEC Article 800), is included in the drop pricing. Removal of cabling not associated with a new installation shall be performed only at the District’s direction under the ‘Demolition of Existing Cabling’ line item, is not E-Rate eligible, and shall be invoiced to the District separately as an ineligible cost. Recommended Category 6 and Category 6A Cable Manufacturers: Belden: Cat 6 2413; Cat 6A 10GXS13 (plenum) Berk-Tek: Cat 6 LANmark-1000 (10032093); Cat 6A LANmark-XTP 2.6 Distribution Frames — MDF and IDF Build-Out (Phases 1 and 2) The Contractor shall furnish and install complete Main Distribution Frame (MDF) and Intermediate Distribution Frame (IDF) equipment rooms and closets, including the items below (where specific need is determined by the District). In Phase 1, this work is limited to the rack-mounted fiber interconnect cabinets and the remediation of MDF and IDF spaces required to install the fiber backbone in accordance with best practices and standards. All remaining items, and the associated network closet remediation for the horizontal cabling, are Phase 2. 19-inch EIA standard 42U-48U data racks and/or wall-mount enclosures (24, 36 or 48 inches tall). Rack-mounted fiber interconnect cabinets with LC duplex couplers, fiber storage management, and blank adapter panels for unused ports. 48-port Category 6 and Category 6A 110-termination patch panels with rear and horizontal cable management. A minimum 30-inch clear working space shall be maintained in front of and behind all equipment racks. 2.7 Communications Outlets and Data Jack System (Phase 2) The Contractor shall furnish and install all communications outlets as follows: Recessed-mount faceplates with four-port configurations. Single and dual drops shall include a four-port faceplate with blank inserts in unused ports. Category 6 or 6A jacks for all standard data outlets. Jacks shall comply with ANSI/TIA-568.0-E, 568.1-E, 568.2-E, and TIA-606-D with T568A pin/pair assignment and ETL verification. Recommended Jack Manufacturers: Belden: Cat 6 AX101320; Cat 6A AX102282 Leviton: Cat 6 61110-RW6; Cat 6A 6110G-RW6 2.8 Patch Cords (Phase 2) The Contractor shall furnish and deliver patch cords as follows, with all colors confirmed with the Owner/Engineer prior to ordering: Color coding by device type: Data: Blue WAPs: Yellow Voice: Orange – E-RATE INELIGIBLE, INVOICE ACCORDINGLY IP Speakers: Purple – E-RATE INELIGIBLE, INVOICE ACCORDINGLY Cameras: Green – E-RATE INELIGIBLE, INVOICE ACCORDINGLY Fire: Red – E-RATE INELIGIBLE, INVOICE ACCORDINGLY HVAC/BAS: White – E-RATE INELIGIBLE, INVOICE ACCORDINGLY Cat6/Cat6A Patch Cable lengths per Network Closet: Patch Cords: 80% – 1 ft, 10% – 3 ft, 5% – 5 ft, 5% – 7 ft Recommended Patch Cord Manufacturers: Belden: Cat 6 C6011 Series; Cat 6A CA211 Series Leviton: Cat 6 6D460-xxx Series; Cat 6A 6ASP0-xx Series Fiber Patch Cables: LC to LC, some LC to ST. Lengths and types are specified in the Pricing Submittal Form. 2.9 Cable Routing Infrastructure (Phases 1 and 2) The Contractor shall provide complete cable pathway systems, including: J-Hook Systems: J-hooks shall be sized to accommodate all specified cabling plus 50% additional capacity. Spacing shall not exceed 4-foot intervals. J-hooks shall be positioned no closer than 18 inches from sources of electromagnetic interference (fluorescent lighting, etc.). Cable Trays: Sized to accommodate all specified cabling plus 50%. Minimum 18 inches from EMI sources. Conduit: Required between buildings, in open exposed ceiling areas, and within walls. Fire Stop Penetrations: All penetrations through fire-rated or smoke walls shall be properly fire-stopped per UL Standards and ANSI/TIA-569-E. Introduction and Background 1.1 Purpose The Pinellas County School District (“District”) is soliciting competitive proposals from qualified contractors to furnish all labor, materials, equipment, and services necessary for the upgrade and modernization of Layer 1 network and telecommunications infrastructure throughout schools within the District. This includes, but is not limited to, structured cabling, fiber optic backbone systems, horizontal copper cabling, telecommunications distribution frames and all associated pathways, support components and infrastructure materials. The District is seeking bids for Category 2 Internal Connections, specifically for structured cabling installation for 98 school sites, listed in Attachment A Layer 1 Project List of Schools. This is intended to be a multi-year project from contract award through June 30 th 2031, with no purchases before April 1, 2027. Multiple vendors may be awarded this contract and participation in the project. The work will be conducted in two phases: Phase 1 (fiber optic infrastructure) and Phase 2 (horizontal Category 6/6A Ethernet cabling), as described in Section 2.2. This procurement is dependent on E-Rate Category 2 funding, as described in Section 8.6. A Form 470 for this opportunity has been submitted to USAC, and is available on their website. 1.2 Background The District operates a large-scale enterprise network spanning multiple school campuses throughout Pinellas County, Florida. The existing telecommunications infrastructure requires systematic upgrading to support current and future data and multimedia services. The District’s published Structured Cabling Specification (Section 27 10 00, current revision July 7, 2026) governs all technical requirements (unless otherwise stated here within) and shall be incorporated by reference into this RFP and any resulting contract. The intent of this upgrade is to install a fully standards-compliant, 10+ Gigabit Ethernet capable infrastructure using fiber optic backbone cabling (OS2 single-mode and/or OM4 multimode), Category 6 horizontal copper cabling, and/or Category 6A cabling — all backed by a 25-year manufacturer performance warranty. 1.3 Project Objectives The District’s primary objectives for this project are as follows: Replace and upgrade aging Layer 1 infrastructure across District school facilities Ensure compliance with current ANSI/TIA and IEEE standards Support 10 Gigabit fiber (IEEE 802.3ae) and up to 100 Gigabit fiber (IEEE 802.3ba) for single-mode and shorter multi-mode runs, 10 Gigabit Ethernet over copper (IEEE 802.3an) and/or 1 Gigabit Ethernet over copper (IEEE 802.3ab) Provide a minimum 25-year certi Source: OpenGov https://procurement.opengov.com/portal/pcsb/projects/322666 Canonical URL: https://govcontractfinder.com/contracts/layer-1-network-and-telecommunications-infrastructure-upgrad-opengov-7777727-project-322666