State and local · OpenGov
2708RFQ - Utilities Continuing Services
Description
The City of Daytona Beach is hereby soliciting responses from qualified Consultants to provide Professional Engineering Services for the following continuing contract categories: Information Technology, SCADA, and Telecommunications Stormwater Management Water and Reuse Distribution / Wastewater Collection Water Supply and Treatment / Wastewater Treatment The City of Daytona Beach will be scoring this project by category. Firms need to submit a separate proposal document for each category they wish to be considered as separate attachments for this single solicitation. The Vendor Questionnaire in Section 9 will apply to all categories for which the firm submits. SCOPE OF WORK Information Technology, SCADA, and Telecommunications Consulting services shall include, but not be limited to, providing professional engineering, technical guidance, planning, evaluation, design, implementation, integration, cybersecurity, and support to the City regarding the operation, maintenance, expansion, modernization, and long-term management of its Supervisory Control and Data Acquisition (SCADA), Operational Technology (OT), Information Technology (IT), and telecommunications systems supporting the City's water, wastewater, reclaimed water, and related utility infrastructure. Scope of Work - Information Technology, SCADA, and Telecommunications Services may include the evaluation of existing systems and infrastructure; development of technology roadmaps; preparation of master plans and capital improvement recommendations; technology selection and procurement support; system architecture; detailed design; programming; configuration; implementation; testing; commissioning; documentation; training; troubleshooting; and lifecycle management. SCADA and OT services may include, but are not limited to: SCADA system assessment, planning, design, modernization, expansion, and integration. Evaluation, design, programming, configuration, and integration of VTScada and related SCADA platforms. Assessment, programming, configuration, integration, troubleshooting, and lifecycle support for Allen-Bradley/Rockwell Automation programmable logic controllers (PLCs), remote I/O, HMIs, industrial computers, and associated control equipment. PLC and SCADA programming, logic development, modification, testing, commissioning, documentation, and backup management. Development and implementation of SCADA standards, programming standards, graphics standards, alarm management standards, naming conventions, system architectures, and operational procedures. SCADA system and control panel design, replacement, upgrades, modifications, and integration with existing utility facilities and processes. Integration of SCADA systems with variable frequency drives (VFDs), instrumentation, analyzers, motor control centers, electrical equipment, generators, process equipment, telemetry systems, and other field devices. Evaluation and integration of industrial communications protocols and technologies, including Ethernet/IP, Modbus TCP/IP, Modbus RTU, OPC, DNP3, and other applicable protocols. Industrial network architecture, design, configuration, troubleshooting, and optimization, including managed switches, industrial Ethernet, fiber optic networks, wireless communications, radio telemetry, cellular communications, and other communications infrastructure. Design and evaluation of SCADA server environments, virtualization, databases, historians, application servers, engineering workstations, operator workstations, HMIs, and associated infrastructure. Development and implementation of system redundancy, high availability, backup, disaster recovery, system restoration, and business continuity strategies for SCADA and OT systems. SCADA asset inventory, lifecycle assessment, obsolescence evaluation, technology replacement planning, and capital improvement planning. Evaluation of existing PLC, HMI, SCADA, server, network, and communications hardware and software for reliability, maintainability, compatibility, cybersecurity, and long-term supportability. SCADA system performance assessments, alarm management, communications reliability assessments, system optimization, and troubleshooting. Integration of SCADA systems with computerized maintenance management systems (CMMS), asset management systems, laboratory systems, business systems, reporting platforms, dashboards, and other City applications where appropriate. Remote monitoring and remote-access solutions for utility facilities, including secure remote access for authorized personnel and consultants. Development and implementation of procedures for SCADA backups, software and firmware management, configuration management, change management, remote access, system recovery, and emergency response. Cybersecurity assessments and recommendations for SCADA and OT environments, including network segmentation, firewalls, demilitarized zones (DMZs), access controls, account management, authentication, vulnerability management, patch management, logging, monitoring, intrusion detection, incident response, and recovery. Coordination of OT cybersecurity requirements and responsibilities between Utilities, City Information Technology, and other City departments. Evaluation and implementation of OT/IT network architecture and governance, including appropriate separation and controlled communication between business IT networks and utility control networks. Cybersecurity risk assessments, vulnerability assessments, asset discovery, vulnerability remediation planning, and development of prioritized capital and operational improvement programs. Support for compliance with applicable federal, state, local, and industry requirements and recognized standards applicable to utility SCADA, OT, cybersecurity, and critical infrastructure. Development and maintenance of SCADA and OT documentation, including network diagrams, control system architecture diagrams, communications diagrams, equipment inventories, IP address documentation, system configurations, programming standards, and operating procedures. Support for cybersecurity incident response, SCADA system recovery, emergency troubleshooting, and restoration of critical utility control systems. Technical support during system failures, major equipment replacements, emergency events, hurricanes, and other conditions affecting the City's ability to monitor and control critical utility infrastructure. Development of training programs and technical training for City personnel responsible for SCADA programming, system administration, operation, maintenance, cybersecurity, and troubleshooting. The Consultant shall have the capability to provide services ranging from planning and advisory assistance through detailed design, programming, implementation, commissioning, cybersecurity assessment, system integration, troubleshooting, emergency response, and long-term lifecycle support. Services may be performed independently or in coordination with the City's staff, City Information Technology Department, SCADA personnel, utility operations and maintenance personnel, existing consultants, contractors, system integrators, equipment manufacturers, and telecommunications providers. The Consultant shall be capable of supporting both existing and future utility technologies and shall provide recommendati Stormwater Management The City of Daytona Beach is seeking qualified Consultants to provide professional engineering services to implement the Utilities Department Capital Improvement Program (CIP). The following service shall include, but not be limited to, design analysis, studies, investigations, pipeline design, citywide and/or project specific stormwater facility design and overall operational aspects of the stormwater infrastructure throughout the City as well as indirect/operating projects including, but not limited to, planning, studies, assessments, funding assistance, investigations, modeling, design, bidding assistance, construction administration, construction engineering inspection, cost estimating, graphics, public meetings, presentations and/or similar work efforts in support of the Utilities Department and their operational and maintenance goals. Scope of Work - Stormwater Management 1. Work consists of multidisciplinary engineering projects relating to the planning, design, and other engineering services associated with projects that may include, but are not limited to, flooding analysis, storm system studies, hydraulic system network modeling; Geographic Information Systems (GIS); instrumentation and controls; Supervisory Control and Data Acquisition (SCADA). 2. Services will include, but not be limited to, evaluation of alternatives, planning, engineering studies/modeling, investigations, on-call engineering, preliminary engineering design, final engineering design (contract documents), permitting, value engineering, bidding assistance, construction administration, construction engineering and inspections services, surveying, and project/program management. Plans shall be prepared in accordance with the most recent City of Daytona Beach technical standards and Standard Details. 3. Work to be performed by the Consultant shall be on a work authorization basis. The work assignment shall be based on discussions and mutual negotiations between the City and the Consultant. The Consultant shall prepare a detailed scope of work, the number of man-hours devoted to the assignment for each position, a schedule, expected reimbursables and a lump sum or not-to-exceed budget proposal for the assignment prior to issuance of the approved work assignments. All proposals for work authorizations shall be supported with established hourly billing rates, and firm multiplier which was established in the Contract. The Consultant shall not perform work under the Contract without written authorization from the City in the form of a Purchase Order or Notice to Proceed. The Consultant shall waive any claim for compensation for any work performed without written authorization. Water and Reuse Distribution / Wastewater Collection The City of Daytona Beach is seeking qualified Consultants to provide professional engineering services to implement the Utilities Department Capital Improvement Program (CIP). The following service shall include, but not be limited to, design analysis, studies, investigations, pipeline design, lift stations, and overall operational aspects of the water, wastewater, and reclaimed water infrastructure as well as indirect/operating projects including, but not limited to, planning, studies, assessments, funding assistance, investigations, design, bidding assistance, construction administration, construction engineering inspection, cost estimating, graphics, public meetings, presentations and/or similar work efforts in support of the Utilities Department and their operational and maintenance goals. Scope of Work - Water and Reuse Distribution / Wastewater Collection 1. Work consists of multidisciplinary engineering projects relating to the planning, design, and other engineering services associated with projects that may include, but are not limited to, water supply; transmission mains, distribution and collection pipe networks; utility relocations; reuse transmission; wastewater pumping systems; storage and/or booster facilities; resiliency analysis/design; hydraulic system network modeling; Geographic Information Systems (GIS); instrumentation and controls; Supervisory Control and Data Acquisition (SCADA). 2. Services will include, but not be limited to, evaluation of alternatives, planning, engineering studies/modeling, investigations, on-call engineering, preliminary engineering design, final engineering design (contract documents), permitting, value engineering, bidding assistance, construction administration, construction engineering and inspections services, surveying, and project/program management. Plans shall be prepared in accordance with the most recent City of Daytona Beach technical standards and Standard Details. 3. Work to be performed by the Consultant shall be on a work authorization basis. The work assignment shall be based on discussions and mutual negotiations between the City and the Consultant. The Consultant shall prepare a detailed scope of work, the number of man-hours devoted to the assignment for each position, a schedule, expected reimbursables and a lump sum or not-to-exceed budget proposal for the assignment prior to issuance of the approved work assignments. All proposals for work authorizations shall be supported with established hourly billing rates, and firm multiplier which was established in the Contract. The Consultant shall not perform work under the Contract without written authorization from the City in the form of a Purchase Order or Notice to Proceed. The Consultant shall waive any claim for compensation for any work performed without written authorization. Water Supply and Treatment / Wastewater Treatment The City of Daytona Beach is seeking qualified Consultants to provide professional engineering services to implement the Utilities Department Capital Improvement Program (CIP) for analysis, studies, investigations, and design associated with the City’s potable water and water reclamation facilities as well as indirect/operating projects including, but not limited to, planning, studies, assessments, funding assistance, investigations, modeling, design, bidding assistance, construction administration, construction engineering inspection, cost estimating, graphics, public meetings, presentations and/or similar work efforts in support of the Utilities Department and their operational and maintenance goals. Scope of Work - Water Supply and Treatment / Wastewater Treatment 1. Work consists of multidisciplinary engineering projects relating to the planning, design, and other engineering services associated with projects that may include, but are not limited to, water supply; water treatment, wastewater treatment; biosolids; plant hydraulic modeling; hydraulic system network modeling; resiliency/hardening efforts, Geographic Information Systems (GIS); instrumentation and controls; Supervisory Control and Data Acquisition (SCADA). 2. Services will include, but not be limited to, evaluation of alternatives, planning, engineering studies/modeling, investigations, on-call engineering, preliminary engineering design, final engineering design (contract documents), permitting, value engineering and inspections services, surveying, and project/program management. Plans shall be prepared in accordance with the most recent City of Daytona Beach technical standards and Standard Details. 3. Work to be performed by the Consultant shall be on a work authorization basis. The work assignment shall be based on discussions and mutual negotiations between the City and the Consultant. The Consultant shall prepare a detailed scope of work, the number of man-hours devoted to the assignment for each position, a schedule, expected reimbursables and a lump sum or not-to-exceed budget proposal for the assignment prior to issuance of the approved work assignments. All proposals for work authorizations shall be supported with established hourly billing rates, and firm multiplier. The Consultant shall not perform work under the Contract without written authorization from the City in the form of a Purchase Order or Notice to Proceed. The Consultant shall waive any claim for compensation for any work performed without written authorization. INTRODUCTION Summary Background Contact Information Timeline DEFINITIONS THESE TERMS ARE STANDARD FOR ALL SOLICITATIONS ISSUED BY THE CITY OF DAYTONA BEACH. THE CITY MAY DELETE, SUPERSEDE, OR MODIFY ANY OF THESE FOR A PARTICULAR SOLICITATION BY USE OF SPECIAL PROVISIONS. Certain terms used herein will have the following meanings. Note some defined terms are not relevant to this Solicitation: Addenda means written or graphic instruments issued prior to the end of the Offer Phase which clarify, correct, or change the Solicitation documents or Contract documents. Also means Addendum. Bid means Solicitation Submission, or Proposal, submitted by a Bidder on the prescribed forms setting forth the prices for the work to be performed, and in the case of a Request for Proposals, the credentials, qualifications, and proposed project approach. Bidder one who submits a response to a Solicitation; also means Proposer or Respondent. City means The City of Daytona Beach, unless the context indicates otherwise, includes the City’s officers, employees, and agents. Commodities means the supplies, materials, goods, merchandise, food, equipment, or other personal property, excluding real property, that the Bidder will be obligated to provide the City under any resulting Contract. References to commodities shall mean goods. Contract means the form Contract, if any, required by the City in order to integrate all terms and conditions therein, provided by the City for the Bidder’s execution and includes 1) the Solicitation documents 2) the Offer Package, 3) the Resolution or Ordinance 4) all Purchase Orders issued pursuant to the Solicitation documents 5) all amendments that may after the date of award be executed by the Bidder and the City 6) any addenda 7) any other Solicitation Documents. Also means an Agreement to purchase Goods or Services or both, regardless of whether the agreement is reduced to a single written document. Electronic Signature means the original signature transmitted and received via electronic transmission of a scanned document, (e.g., PDF or similar format) and are true and valid signatures for all purposes hereunder and shall bind the parties to the same extent as that of an original signature. Any such electronic counterpart shall be of sufficient quality to be legible either electronically or when printed as hardcopy. The City shall determine legibility and acceptability for public record purposes. Florida Prompt Payment Act means F.S. §§ 255.0705—255.078, as amended from time to time. Goods means the supplies, materials, commodities, merchandise, food, equipment, or other personal property, excluding real property, that the Bidder will be obligated to provide the City under any resulting Contract. References to Goods shall mean Commodities. Local Vendor means a person or business entity which has maintained a permanent place of business with full-time employees within the city limits for a minimum of six months prior to the date Offers were received for the purchase or Contract at issue, which generally provides from such permanent place of business the kinds of Goods or Services solicited, and which at the time of the Solicitation fully complies with state and local laws, including City zoning and licensing ordinances. Notice of Intent to Award (NOI) means a written notice given by the City stating that staff is recommending award to the listed Proposer. It includes instructions for completing and submitting any Contract that accompanies the NOI. Offer means Solicitation Submission, Bid, or Proposal, submitted by a Bidder on the prescribed forms setting forth the prices for the work to be performed, and in the case of a Request for Proposals, the credentials, qualifications, and proposed project approach. Platform means OpenGov, the software currently used by the City. All communications regarding this Solicitation will be posted at www.codb.us/841/purchasing through the Public Solicitations link. Bidders MUST submit Offers through the Platform. The Platform is utilized by the City and the Bidders to: 1) Allow Bidders to register and manage their company records, 2) Post and issue City Solicitation packages for Bidders from inception to award of a Solicitation, 3) Allow Bidders to submit an Offer Package online, electronically, through the Platform, 4) Allow Bidders to view all public record documents related to a
Published attachments
Addenda and notices
Addendum #1 · 1
Addendum #1 - 11.16.26 - The Teams meeting links have been added and updated to the Pre-Bid and Proposal Openings. Please use the See What Changed link to view all the changes made by this addendum.
Official Notice #1: 2708RFQ - Utilities Continuing Services - Pre-Bid · 1
The pre-bid for 2708RFQ - Utilities Continuing Services has been rescheduled to Monday, November 23, 2026, at 2:00pm. Please utilize the Teams link in the timeline to access the pre-bid.
Public questions and answers
Please provide the contract term.
The Contract is an initial 3-year term with two (2) optional 1-year extensions for a total possible term length of 5-years.
The RFQ provides conflicting guidance regarding resume page limits. Please clarify whether resumes for all key personnel are limited to one page or two pages each.
All resumes for key personnel need to be kept at one (1) page each.
Tab 5 asks for a fee proposal with a full breakdown of costs and hours. Is this required since this is a continuing services contract?
No pricing is to be submitted with this RFQ.
Tab 5 asks to provide a fee proposal for all expenses broken down by task, including direct and indirect costs and expenses, estimated number of hours, and a total estimated cost for the project. Is this required, as this is a continuing services contract?
No pricing is to be submitted with this RFQ.
Paragraph 7, Tab 5, indicates that a Fee Proposal is required. Please confirm whether a Fee Proposal is required as part of the RFQ response, considering the procurement requirements of Florida's Consultants' Competitive Negotiation Act (CCNA), Section 287.055, Florida Statutes.
There is no fee proposal required for this RFQ.
There appear to be discrepancies between the requirements outlined in Paragraph 7 and Paragraph 8 of the RFQ. Are these two paragraphs intended to coordinate with one another, and if so, which requirements should take precedence where the provisions differ?
Section 7 has been removed (Proposal Submittal and Requirements). Please refer to the new Section 7 (Evaluation Criteria) for response criteria.
The RFQ states that the proposing firm must be registered with the Florida Board of Professional Engineers for a minimum of 10 years. Please clarify whether this requirement refers to the firm's Florida engineering Certificate of Authorization/engineering business registration or the firm's registration to conduct business in the State of Florida.
It refers to the Certificate of Authorization/Engineering Business Registration.
Paragraph 8 identifies a five (5)-page limit for the Firm Experience section and also requests up to three (3) continuing contract examples, with each example permitted up to two (2) pages. Please clarify whether the three continuing contract examples are included within the five-page Firm Experience limit or are permitted in addition to the five pages.
Up to 11 total pages should be submitted, 5-page limit for the firms experience and 3 continuing contract examples that can be total of 2 pages per example.
With the previous Section 7 removed, and the Evaluation Criteria becoming the new Section 7, does this mean that no approach is to be included in our proposals since the Evaluation Criteria does not include scoring for an approach? Please confirm.
No approach needs to be given in the proposals. These are continuing services contracts that will be work authorization based, so there are no specific projects to create approaches for at this time.
In Sections 3.4, 3.6 and 3.8 it is noted that work will be performed by the Consultant on a work authorization basis. This is not stated under section 3.2 for the IT, SCADA, and Telecommunications category. Will IT, SCADA, and Telecommunications category work also be performed on a work authorization basis?
Yes, work will be performed on the IT, SCADA, and Telecommunications on a work authorization basis.
The City has confirmed that we are limited to 7 one page resumes under the Ability of Professional Personnel section. However, no page limit is provided for the "Level of qualifications and experience of key project team and key subconsultants" criteria of this same section. Is there a page limit for this piece?
One page per “level of qualifications and experience of key project team and key consultants."
Please clarify if each category submission is to be a completely separate submission package (7 different resumes, projects, references, etc.), or if the same projects, team members, and references can be used in each category we submit on.
Each category submission has to be a separate submission package. For example, if a firm checks two boxes, then they would need to have two separate packages submitted for the two boxes that are checked. When you submit your proposal, you will be able to upload more than one proposal.
The City designates 5 pages for similar experience as well as requesting up to three continuing contract examples. Can some of the examples in the first 5 pages be continuing contracts as well?
Yes, if it's similar experience.
Can the City confirm if we are able to include a Cover Letter with our submission(s)?
A cover page can be submitted but can only be one page.
May a firm submitting as a prime respondent also serve as a sub-consultant on another prime firm's submittal?
Yes.
Are we to include an org chart in these submissions, and if so, what section should it be in, and can it be on 11x17?
An org chart should not be submitted with your submittal. The project team’s key individuals should be included in the submittal of your proposal.
Could you please share the Incumbent firms for the 4 continuing contract categories?
SCADA/Telecommunications: Not specifically called out under the recently expired continuing services contracts. Stormwater Management: • Zev Cohen & Associates, Inc. • DRMP • Four Waters • Mead & Hunt • SInghofen & Associates, Inc. Water Supply and Treatment / Wastewater Treatment (Inside the Fence): • Carollo • Hazen & Sawyer • Tetra Tech • Wright Pierce Water Supply and Treatment / Wastewater Collection (Outside the Fence): • BFA • Carollo • Halff • Hazen & Sawyer • Mead & Hunt • McKim & Creed • Tetra Tech • Wright Pierce
Can a firm be selected for more than one category?
Yes.
For Evaluation Criterion No. 4: Firm Location, should this be addressed as a separate section/tab within the proposal, and if so, is there a page allocation for this criterion?
Typically, the address of the office for the Prime Contract Manager’s Office location is stated on the information provided within the previous 3 criteria. If your firm does not typically include that information, please include the address of the office for the Prime Contract Manager within information on the submitted documents. Due to the possibility of the high number of responses to this RFQ, if your Prime Contract Manager office location is not clearly stated on your submittals, you will receive a score of zero for criteria number 4.
OpenGov categories
- 28029 · Communications/Telecommunications Cable and Wire
- 92537 · Facilities Design Services, Engineering
- 92570 · Municipal Engineering
- 92595 · Utilities (Gas, Steam, Electric)/Engineering
- 92596 · Waste Water Treatment Engineering
- 92597 · Water Supply, Treatment, and Distribution/Engineering
- 95114 · Infrastructure, Telecommunications
- 95889 · Telecommunications Management Services
- 96896 · Water and Wastewater Treatment Services