Skip to content
← Back to search
Award NoticeAwarded

AWARD NOTICE

DEPT OF DEFENSE · TELECOMMUNICATIONS DIVISION- HC1013

This notice records an award. Find active opportunities

Award Information

This solicitation resulted in an award to T2 TECHNOLOGIES, INC. for approximately $170,686 on February 6, 2025. Similar contracts are typically issued by DEPT OF DEFENSE under 517111 (Wired Telecommunications Carriers).

Award Number
HC101325PA154
Award Amount
$170,686
Award Date
February 6, 2025
Awardee
T2 TECHNOLOGIES, INC.

Contract Details

Notice ID
HC101325QA033
Opportunity Type
Award Notice
Sub-Agency
DEFENSE INFORMATION SYSTEMS AGENCY (DISA)
Office
TELECOMMUNICATIONS DIVISION- HC1013
Posted Date
Thursday, February 6, 2025
Response Deadline
Not specified
PSC Code
DG11
Set-Aside
Full & Open Competition
Place of Performance
Not specified
Status
Awarded

Description

1. IN ACCORDANCE WITH INQUIRY HC101325QA033, PROCEED TO PROVIDE, INSTALL AND MAINTAIN A 10GB, NON-SWITCHED, ETHERNET IP BACKBONE CIRCUIT BETWEEN BLDG 2201, RM 5440 STC, 2201 C STREET, NW, WASHINGTON DC 20520 AND BLDG 2310, ROOM 130, 8575 JOHN J KINGMAN ROAD, FT BELVOIR VA 22060. A. PRIOR TO TESTING VENDOR MUST CONTACT CASA AT: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEASE-BB-T@MAIL.MIL. B. NO BUILDS ARE AUTHORIZED AT FT BELVOIR, VENDOR **MUST** USE EITHER ZAYO OR VERIZON FOR THE CONNECTION INTO BUILDING 2310 AT FT BELVOIR. C. VENDOR FOR THE FT BELVOIR SERVICE POINTS ARE REQUIRED TO HAVE A MINIMUM (S) CLEARANCE. 2. THE SERVICE DATE TO BE MET IS: 04 JUN 25 (SIP). THE GOVERNMENT WILL ASSESS CONSIDERATION IAW STANDARD PROVISION 42 FOR DELAY ON DELIVERY OF CIRCUIT ON CONTRACTED SERVICE DATE. 3. ESTABLISH TSP: TSP0N73QT-01 4. SEE ATTACHMENTS AND UNIQUE INSTALLATION FACTORS FOR TECHNICAL REQUIREMENTS SPECIFIC TO THIS ORDER. 5. CONTRACTOR MUST UPLOAD NOTICE OF COMPLETION IN IDEAS. 6. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH CSA T2T000109EBM AND MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS (SDP) FROM CSA T2T000109EBM; MEANING THE PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MANHOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER BUILDS. ADDITIONALLY, AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM CSA T2T000109EBM.

Documents and contact

No public document links were provided with this record.

Check the official notice for attachments and access requirements ↗

Contact
JOHN WARNER
Email
john.d.warner28.civ@mail.mil
Phone
Not Applicable
Loadingchange history…
Loadingrelated notices…