Countywide Chemicals

Description

As requested by the Public Utilities Water Division (hereinafter, the “Division or Department”), the Collier County Board of County Commissioners Procurement Services Division (hereinafter, “County”) has issued this Invitation to Bid (hereinafter, “ITB”) with the intent of obtaining bid submittals from interested and qualified Bidders in accordance with the terms, conditions and specifications stated or attached. The Bidders, at a minimum, must achieve the requirements of the Specifications or Scope of Work stated herein. All references to “Bidder” are also referred to as “Contractor” and “Vendor.” The results of this solicitation may be used by other County departments once awarded according to the Board of County Commissioners Procurement Ordinance. Historically, County departments have spent approximately $4,000,000; however, this may not be indicative of future buying patterns. Project Details Important Instructions for Electronic Submittals The County of Collier, FL is accepting electronic bid submissions. Bidders shall create a FREE account with OpenGov Procurement by signing up at https://procurement.opengov.com/signup . Once you have completed account registration, browse back to this page, click on "Draft Response", and follow the instructions to submit the electronic bid. Scope of Work or Project Details Please see the Attachments section for specifications and attachments. Introduction Summary As requested by the Public Utilities Water Division (hereinafter, the “Division or Department”), the Collier County Board of County Commissioners Procurement Services Division (hereinafter, “County”) has issued this Invitation to Bid (hereinafter, “ITB”) with the intent of obtaining bid submittals from interested and qualified Bidders in accordance with the terms, conditions and specifications stated or attached. The Bidders, at a minimum, must achieve the requirements of the Specifications or Scope of Work stated herein. All references to “Bidder” are also referred to as “Contractor” and “Vendor.” The results of this solicitation may be used by other County departments once awarded according to the Board of County Commissioners Procurement Ordinance. Historically, County departments have spent approximately $4,000,000; however, this may not be indicative of future buying patterns. Timeline Release Project Date: October 13, 2026 Question Submission Deadline: November 20, 2026, 5:00pm Proposal Submission Deadline: December 1, 2026, 3:00pm Procurement Contact Lisa Farnsworth Procurement Strategist I 3295 Tamiami Trail East BLDG C-2 Naples , FL 34112 Email: lisa.farnsworth@collier.gov Phone: (239) 252-4840 Vendor Questionnaire Attachments

Published attachments
Addenda and notices
Public questions and answers
  • How many References Questionnaires (your Form 5) are we required to submit with the subject bid?

    If you have references, you are welcome to include them; however, they are not required for this solicitation.

  • Was there a previous incumbent? If so, can you share their price proposal? Has there been any changes to the scope from the last? If so, what has changed? Did the previous incumbent complete the project term? Is this solicitation the same length of time? If previous incumbents exist, when is the contract set to end? Is there a bid tabulation available for this solicitation? If so, could you please share a copy with us?

    Please see under supporting documents, Attachment O – 21-7921 Bid Tabulation and Solicitation and Addendum #1

  • Is there a set budget for this solicitation?

    Please refer to page 2 of the solicitation.

  • Is there a projected award and start date?

    No. The dates would depend on many factors, including the number of bids submitted, responsive and responsibility checks, verifications, and board of commissioners availability.

  • I wanted to clarify that Form 5: Reference Questionnaire is not required to be filled out and submitted with this bid?

    Please refer to Question and Answer 1.

  • What manufacture and brand of scale inhibitor is currently used at N Plant NF, N Plant RO, S Plant RO?

    American Water Chemicals – Manufacturer AWC A-102 Plus – Chemical

  • Is acid currently used at the N Plant NF to bring down the feed pH, and if so, what is the pH currently being brought down to?

    Yes, the North Water Plant currently injects acid into the NF raw water stream to target a feed water pH of 6.7.

  • What is the dose rate of each scale inhibitor at N Plant NF, N Plant RO, S Plant RO?

    2.53 ppm North Plant NF 2.5 ppm North Plant RO 2.51 ppm South Plant RO

  • Could you confirm if the incumbent scale inhibitor is bid again, will the provider of that product need to use present day dosage rates in their submission? This is to ensure fairness and that the current supplier cannot supply an “artificially” lower recommendation to bring the overall costs down on paper.

    The incumbent supplier shall base its proposed dosage rate on current operating conditions and demonstrated chemical performance. Any proposed dosage rate that differs from the current application rate must be supported by sufficient technical documentation demonstrating that the proposed dosage will achieve the County’s required treatment objectives. All bidders, including the incumbent supplier, will be held to the same performance requirements and evaluation criteria. The County reserves the right to request additional supporting documentation or clarification of proposed dosage rates to ensure a fair and consistent evaluation of the overall chemical treatment costs.

  • What is the current price per lb for the scale inhibitor? If more than one inhibitor is being used please specify.

    Please see Addendum 2 and Supporting Attachment P – 21-7921 Bid Tabulation Effective 3-1-26

  • The excel bid file 26/8705_Bid_Schedule states Award: Lowest price per line item. Exhibit_J2_26-8705_Specifications pg 4 W- 9 Scale Inhibitor in the 4th bullet point specifically states “Bid proposals will be evaluated considering overall treated water cost using a calculation including unit price, and required feed dose while meeting COUNTY requirements for delivery time, warranty, technical service, and current NSF 60 certification”. This suggests the total cost to treat the water will be calculated using unit price and required feed dose. Could you please clarify what the decision to award will be based on. Will simply be price per lb, or a combination of price per lb + dosage rate to calculate total annual consumption.

    Overall treated water cost using a calculation including unit price, and required feed dose

  • If it is total overall consumption, could you please provide the equation you will use to calculate overall consumption of scale inhibitor to ensure all participants understand how costs will be calculated?

    The County will evaluate scale inhibitor pricing based on the overall cost of treatment, considering both the proposed chemical dosage rate and the bid price per pound. For comparison purposes, the cost per million gallons of treated water will be calculated as follows: Cost per Million Gallons = Proposed Dosage (mg/L) × 8.34 × Unit Price ($/lb) The historical chemical usage and existing dosage rates provided in the solicitation are for reference purposes and reflect the incumbent product's established operating conditions and demonstrated performance. Alternative products may require different dosage rates to achieve the County's required treatment objectives. Proposed dosage rates must be supported by technical documentation demonstrating the ability to meet those objectives. All bidders will be evaluated using the same calculation methodology and performance requirements.

  • Pg 9 of Exhibit_J2_26-8705_Specifications state “Annual Estimated Quantities: 163,000 pounds”. Exhibit_Q_26-8705_Summary_of_Chemicals for row W-9 give a TOTAL ESTIMATED QUANTITY annually of 23,000 lbs for NCRWTP and 40,000 lbs for SCRWTP. This seems incorrect as the next column Delivery Quantity Maximums states 38,000lbs for each. Please clarify what the actual estimated quantities are?

    Annual Estimated Quantities: 163,000 pounds is accurate. Please use 123,000 lbs for NCRWTP and 40,000 lbs for SCRWTP.

  • Does the North County plant have separate scale inhibitor holding tanks for the NF and RO?

    One bulk tank at the North County Regional Water Treatment Plant.

  • Approximately how many deliveries of your current scale inhibitor do you get annually per plant?

    These are approximate and could vary due to production needed to meet system demand. SCRWTP – 2 deliveries NCRWTP – 4 deliveries

  • Approximately how often do you CIP each train for the North County NF and RO and South County RO?

    Annual CIP’s historically

  • If we are unable to deliver scale inhibitor by bulk tanker, is it possible to deliver by other means, like totes?

    In the event of an emergency we would accept totes, but the County would expect all deliveries via tanker.

  • Regarding item WW-5, wastewater collection-system degreaser: Would the County consider ODR&FOG, a mineral-based powder supplied in 5-gallon buckets, under the solicitation’s approved-equal provisions? The product is intended to help loosen and mobilize accumulated fats, oils, and grease while treating hydrogen sulfide in lift stations, sewer lines, and force mains. It differs from the specified liquid soybean-oil degreaser in chemistry, packaging, and application method. If this alternative can be considered, please identify the required technical documentation, samples, testing, and approval deadlines, and clarify how pricing should be submitted given the different unit of measure. If it cannot be considered under WW-5, please advise whether the County has a separate process for requesting an operational evaluation.

    No, Collier County would not accept the product as an equivalent due to the higher potential for eye contact, inhalation, skin contact, and ingestion.

  • What needs to be done specifically to qualify a corrosion inhibitor blend with the county?

    Please refer to Specification – Water & Wastewater Department Section W-4

  • What percentage blend of the PO4 is required?

    80% Orthophosphate/20% Polyphosphate.

  • The bid paperwork says that the corrosion inhibitor needs to be food grade. Should this say NSF approved or AWWA standards instead?

    Please refer to Specification – Water & Wastewater Department Section W-4 Physical Properties

  • Does a phosphate blend of 75/25 ortho to poly suffice or does the blend need to be 80/20 to qualify?

    No, it must be 80/20.

  • What is the minimum order quantity for the Muriatic Acid?

    Vendor to please clarify your questions since there are two different muriatic acids listed based on type and use.

  • For bidding purposes, can the County clarify whether the existing product is a sodium hexametaphosphate (SHMP)-based chemistry, which is commonly used for water stabilization in the lime softening process, or provide the general phosphate chemistry currently utilized for this application?

    Chemical W-7 Liquid PO4 – the existing product is a sodium hexametaphosphate (SHMP)-based chemistry.

  • We can deliver mini bulk totes pumped into your tanks for corrosion inhibitor deliveries, correct? We can deliver 2,310 gallons per delivery off of our box trucks and keep the product stored at our warehouse for future deliveries.

    W-4 Corrosion Inhibitor would be preferable to deliver bulk, if delivered by mini bulk totes the vendor would be responsible for transferring from totes to the bulk storage tanks. W-7 Liquid PO4 would be delivered in chemical totes. 275 gallon – 350 gallon totes would be acceptable.

  • What is the minimum order quantity for the PR3 Muriatic Acid

    The minimum order for muriatic acid for Parks and Recreation will be 500 gallons across 5 locations. The average order is over 1000 gallons.

  • Exhibit J2, Section W-9 (Scale Inhibitor), states that bids will be evaluated based on overall treated water cost, considering both unit price and required feed dosage. However, the general Bid Schedule indicates that awards will be based on the lowest price per line item. Unlike many other treatment chemicals, antiscalant products can vary significantly in their required feed dosages depending on their formulations and effectiveness under the specified water quality and operating conditions. As a result, a product with a lower unit price ($/lb) may require a substantially higher dosage, ultimately resulting in greater chemical consumption and higher operating expenses for the County. Evaluating bids solely on unit price, without accounting for the required dosage, could therefore result in an award to a product that does not provide the lowest overall treatment cost to the County. Given that Exhibit J2, Section W-9 specifically identifies overall treated water cost as the basis for evaluation, please confirm that: 1. Scale inhibitor bids will be evaluated and awarded based on the lowest overall treatment cost ($/1,000 gallons of treated water), accounting for both the proposed unit price and required feed dosage, rather than unit price ($/lb) alone. 2. Bidders will be required to submit antiscalant projections using the water quality and operating conditions provided in the solicitation to substantiate their proposed feed rates, and that these projections will be considered

    The County will evaluate scale inhibitor pricing based on the overall cost of treatment, considering both the proposed chemical dosage rate and the bid price per pound. For comparison purposes, the cost per million gallons of treated water will be calculated as follows: Cost per Million Gallons = Proposed Dosage (mg/L) × 8.34 × Unit Price ($/lb) The historical chemical usage and existing dosage rates provided in the solicitation are for reference purposes and reflect the incumbent product's established operating conditions and demonstrated performance. Alternative products may require different dosage rates to achieve the County's required treatment objectives. Proposed dosage rates must be supported by technical documentation demonstrating the ability to meet those objectives. All bidders will be evaluated using the same calculation methodology and performance requirements.

  • Fow W-9 Scale Inhibitor the table under PRETREATMENT SCALE INHIBITOR PROCUREMENT SPECIFICATION under the N Plant NF column and Minimum feed pH row says 6.9. Below that row, it says Feed sulfuric acid addition and then Minimum to achieve required feed pH. It reads as if 6.9 is the minimum pH allowed to be used. The answer to Question 7 states the facility is currently injecting enough acid to bring the feed water pH to 6.7. Are we allowed to also bring down the feed pH to 6.7 for our projections as with the incumbent?

    Yes, that is allowed.

  • If we are able to inject less acid for the N Plant NF to keep the feed pH higher than 6.7, which it's currently at, will the decrease in acid usage/costs also be taken into account (assuming scale can be controlled)? If so, could you please supply a price per lb for acid to be used for the calculation?

    See answer to Question 28.

  • Can you confirm bid bond required with this submission and the amount?

    A bid bond is not required for this solicitation.

  • For bidding purposes, the specification identifies an 80/20 ortho/polyphosphate blend for corrosion control. Can the County provide the basis for selection of this specific blend ratio, including the primary treatment objectives (e.g., mild steel, lead and copper corrosion control, iron and manganese sequestration, red water control, scale stabilization, or other system-specific considerations)? Additionally, if the County elects to consider alternative corrosion control inhibitor formulations or equivalent blends, can the County provide representative finished water and distribution system water quality data to assist vendors in evaluating suitability and anticipated performance? Information such as calcium hardness, alkalinity, pH, manganese, iron, lead, copper, chloride, TDS, and any available information regarding distribution system metallurgy (e.g., cast iron, ductile iron, copper, galvanized steel, lead service lines, etc.) would be helpful in evaluating corrosion control and metal sequestration performance. If representative finished water and distribution system water quality data are not readily available, would the County permit interested vendors to collect water samples and perform bench-scale or in-house evaluations for the sole purpose of assessing corrosion control inhibitor suitability and anticipated performance relative to the County's treatment objectives? Beyond product cost and compliance with the specification, would the County place value on additional

    Collier County will not deviate from an 80/20 Ortho/Polyphosphate blend. This chemical was selected and identified during a previous corrosion control engineering study.

  • The current scale inhibitor feed rates are identified as 2.53 ppm for North Plant NF, 2.50 ppm for North Plant RO, and 2.51 ppm for South Plant RO. Based on the membrane train counts and design capacities provided in the specifications, operation of all NF and RO trains at design capacity on a continuous 24-hour/day, 365-day/year basis appears to result in an estimated annual scale inhibitor consumption significantly greater than the stated annual quantity of 163,000 lb/year. Can the County provide membrane systems utilization rates, annual operating hours, or annual permeate production volumes used in developing the estimated annual chemical quantity? This information would assist vendors in accurately evaluating chemical consumption and treated water cost.

    The County does not operate at max capacity 24/7/365. The stated annual quantity is a representative estimate based on recent historical chemical usage and production.

  • Is a bid bond required to be submitted with the bid proposal?

    A bid bond is not required for this solicitation.

  • Exhibit J2 – Items W-4 (Corrosion Inhibitor) and W-7 (Liquid PO4): The specifications do not state a required product appearance or color. Our standard NSF/ANSI 60–certified products are clear/colorless. Some utilities request a food-grade blue dye for easier visual confirmation of chemical presence in day tanks and feed lines. Please confirm whether Collier County requires, prefers, or will accept a blue-dyed formulation, or whether the product must remain undyed/clear.

    The County does not require or currently utilize the referenced chemicals with food-grade blue dye added for easier visual confirmation.

  • If the signatory is not the person listed on the Sunbiz filing (President), will a resolution executed by the Secretary be sufficient to satisfy the signatory requirements?

    A company representative not listed on Sunbiz may be authorized to sign on behalf of the company by providing a letter on company letterhead granting such authority. The letter must be signed by an individual listed as an authorized signatory on Sunbiz.

  • The County indicated that the 80/20 ortho/polyphosphate blend was selected through a corrosion control engineering study. Can the County confirm whether the requirement is intended to ensure achievement of specific corrosion-control and water-quality objectives, or whether the County has determined that alternative NSF/ANSI 60-certified ortho/polyphosphate formulations are incapable of achieving those same objectives? If alternative formulations were evaluated, please identify the blend ratios considered and the basis for their rejection.

    The County is remaining with the 80/20 ortho/polyphosphate blend. No other blend will be considered.

  • Bid Clarification Request – Soybean Lift Station Degreaser Pricing The soybean lift station degreaser listed in the current solicitation does not appear as a separate line item in the County’s previous bid tabulations. Could the County please provide the most recent unit price it paid for this product? Please include the purchase date, vendor, product name, package size, unit of measure, and whether freight was included in the price. If the product was previously purchased under a different line-item description or through a separate purchase order, purchasing card transactions, or field purchase order, or under another contract, please provide that description and the applicable bid, contract, or purchase order number.

    No vendors bid on degreaser with the last solicitation, and we have had no means to purchase degreaser on a consistent basis. The last contract we had that included degreaser was 17-7091 where we paid $9.98/gallon (Bid Tab Summary attached).

Plain text

OpenGov categories

  • 88500 · Water And Wastewater Treating Chemicals
  • 88551 · Disinfectants, Wastewater
  • 88594 · Water Treating Chemicals (Not Otherwise Classified)
  • 88596 · Recycled Water and Wastewater Treating Chemicals
  • 89015 · Complete Water Treatment Systems, Chemical
  • 89087 · Water Treatment Equipment (Not Otherwise Classified)
  • 91263 · Maintenance and Repair, Swimming Pool (Includes, Swimming Pool Water Treatment Services)
  • 91391 · Maintenance and Repair, Wastewater Treatment Plant
  • 92596 · Waste Water Treatment Engineering
  • 96895 · Wastewater Treatment Plant, Operations, and Testing
  • 96896 · Water and Wastewater Treatment Services