Skip to content
← Back to search

State and local · OpenGov

Opportunityopen

Design, Installation, Maintenance and Repair of a Supervisory Control and Data Acquisition (SCADA) System.

Description

Design, Installation, Maintenance and Repair of a Supervisory Control and Data Acquisition (SCADA) System. SCOPE OF WORK Introduction It is the intent of this Request for Qualifications for the selection of Design, Installation, Maintenance and Repair of a Supervisory Control and Data Acquisition (SCADA) System. The City has standardized our Lift Stations, Potable Water Wells, and the Water Tower location with Badger Meters (FKA SmartCover, FKA Data Flow Systems) SCADA System. Scope of Work The scope of services is anticipated to include, but is not limited to: DATA FLOW SYSTEMS TAC II SCADA SCADA SYSTEM TECHNICAL SPECIFICATION SCADA SERVER – HARDWARE & SOFTWARE HYPER SCADA SERVER The Hyper SCADA Server (HSS) shall be a self-contained data collection and information server housed in a wall-mounted enclosure. It shall use a Modular Backplane for power distribution and modularity. The HSS shall contain dual CPU’s for Hot-Standby Redundancy, network switchgear, fiber optic converter, power supply units, backup batteries, and surge protection. The HSS shall be wall mounted in a climate-controlled facility. The HSS enclosure shall feature a clear window on the front door to allow observing of status LED’s without opening the door. The HSS shall connect to a Primary Workstation Computer via a direct Ethernet connection. This direct connection permits Primary Workstation Computer access to the HSS should a separate local area network (LAN) experience a failure. The Primary Workstation Computer will be designated as a data back-up location. The owner’s personnel shall be able to sign onto the system from properly configured workstation computer(s) connected to the HSS via a network or phone line connection. HYPER SERVER MODULE The Hyper Server Module (HSM) shall be an embedded computer that includes a CPU, memory, storage, two on-board voice-grade modems, and network interface. All communications to and from the HSM shall be through the network connection and module-mounted modems. A button shall be provided to direct the CPU to an orderly shutdown process. Status LEDs shall be provided to indicate CPU activity and system status. Configuration straps at the card edge shall be provided to enable system-level configuration. Replacement of an HSM shall not require the use of tools and shall be nothing more than changing the module in the card edge connector. COMMUNICATION PROTOCOLS The communication protocols supported by the system shall include: 1) TAC II Radio, 2) DFP Radio, 3) Net-DFP, 4) MODBUS ASCII, 5) MODBUS RTU, and 6) MODBUS TCP. The HSS shall be capable of simultaneously polling multiple communications links, including Cellular All RTUs utilizing TAC II and DFP radio protocols shall have the capability of being used as a digipeater for relaying messages from the HSS to any other RTU. The response messages from the destination RTU shall be digipeated to the HSS by the same RTU that forwarded the message to the destination RTU. Mapping of digipeating shall be user-configurable from any workstation computer. Modifications or programming at the RTUs shall not be required. Four (4) levels of digipeating shall be supported. The system shall be capable of utilizing up to 505 radio addresses per communications link, and up to 15 function modules per RTU. All remote interfaces directly connected to the HSS shall be fiber optic isolated for transient voltage protection. HT4 SCADA Software General The SCADA Software shall be the latest version of Linux-based HT4. Software Licensing HT4 shall have licenses to allow a minimum of 60 concurrent users. HT4 shall have licenses for unlimited tags and screens. Critical Data Redundancy HT4 shall feature an automated backup routine to protect the system from the loss of critical data. The data redundancy process shall use a designated Windows workstation as a backup location. This workstation shall be equipped with a hard drive large enough to hold all of the system's backup data and shall be configured as a remote backup location. Data backup shall occur every night at midnight. HT4 shall first make a local copy of the data (stored on the HSM) and then backup the data to the designated Windows computer. An entry shall be made in the current day's Access Log to indicate if the previous day's backup was successful or failed. Drivers HT4 shall utilize one to seven concurrent communication drivers. HT4 shall support the following driver types: TAC II Radio – An efficient serial radio protocol incorporating time-stamped data. DFP (Derivative Fractional Protocol) – An optimized serial radio protocol utilizing store and forward techniques. Net DFP – An optimized network and cellular protocol utilizing store and forward techniques. Modbus – HT4 supports Modbus ASCII, Modbus RTU, and Modbus TCP. Standard 5-digit registers must be used and formatted with 0XXXX for digital outputs, 1XXXX for digital inputs, 3XXXX for analog inputs, and 4XXXX for analog outputs with the DFS device being the Master in the Modbus communications architecture. Packing Modbus digital input, digital output, and analog input registers into the 4XXXX range is not permitted. Analog points over the Modbus link shall be unsigned integers (0-65535, 16 bit, point type AI or AO) or 32-bit floating points (point type EI or EO) System Partitioning HT4 shall be supplied with system partitioning. The system-partitioning feature shall allow up to eight independent systems to run concurrently on the HSS. Each partition user shall have all the features mentioned in this specification for the RTUs assigned to that partition only. Alarms, reports, and displays from RTUs assigned to one partition shall not be accessible to users in other partitions. In effect, the partitioning system shall appear to each user as if theirs is the only partition on the system; the other partitions shall be invisible to the user. All partitions shall have their own full-function access to the auto dialer / voice / pager / E-mail functions. System User Permissions HT4 shall allow user permissions with password protection for control functions, acknowledgment functions, shutdown functions and configuration functions. Each user shall be assigned to a system partition. RTU Configurations Configuration of RTUs in the polling database shall be accomplished using fill-in-the-blank questions. The configuration process shall offer the following options: Driver type Driver name Driver number RTU (station) name RTU number Radio features Polling priority Digipeating path (TAC II Radio driver only) I/O type Point name and characteristics Alarm Configuration HT4 shall allow users to configure alarms for all system I/O points. All alarms may be configured with any or all of the following options: Announce locally via speakers connected to any or all workstations. Call out an announcement to a list of configured telephone numbers. Email via third-party relay server. Delay before alarm becomes active in the system. Time allowed to pass before an acknowledged and still-active alarm is re-announced (Snooze). Scheduled and Auto Controls HT4 shall allow users to create scheduled controls and auto controls. Scheduled controls allow controls to occur on selected days of the week at specific times. Digital controls can be scheduled to come on or go off at a specific time. Analog controls can be scheduled to be set to a desired engineering value. Auto controls can be used to automate and facilitate the controlling of hardware in the field. Configuring an auto control instructs the system to perform a certain function when a specific event occurs. Modbus TCP/IP Emulation HT4 shall act as a Modbus TCP/IP slave device for any configured point. This shall include any physical and virtual RTU I/O point in the system. The native Modbus register format shall be utilized. Five (5) digit registers must be used and formatted with 0XXXX for digital outputs, 1XXXX for digital inputs, 3XXXX for analog inputs, and 4XXXX for analog outputs. Paired Modbus registers shall be configurable as EO or EI points to represent Modbus floating point values. System Activity Logs and Journals HT4 shall maintain time-stamped data logs pertaining to system activities. These shall include: System access – Each entry includes the username and IP address (where applicable) of individual who: Shutdown the system Started the system Logged in to the system Logged out of the system Made or changed a configuration Alarms – Each entry includes a source [the value that caused the alarm, the user-name of the individual who acknowledged the alarm, or the phone number called (callout number)] and the alarm activity that was recorded: Alarm occurred Alarm was acknowledged System called out an alarm alert Alarm was still active after snooze time Controls – Each entry includes the username of the individual who attempted the control and the control activity that was recorded: A user without control permission attempted to control a point An attempt to control the point was made Control was successful Control was not successful Radio errors – Each entry lists the type of error that was recorded: No response from station Station response was aborted Address format was bad Message format was bad Checksum or CRC error occurred Status change journal – One journal is created per day to record changes in status. An entry is ma Viewers Stats Viewer HT4 shall include a screen that displays information on the current status of important system-level points. For redundant systems, the statistics shall be for the active Hyper Server Module (where applicable). The Stats viewer displays the following: CPU usage System date and time Backup status CPU temperature Redundant HSM status Hard Disk Driver (HDD) usage RAM memory usage HSM up time AC power status Number of drivers Number of stations Number of points Number of TCP connections Battery voltage Driver loop times Stations Viewer HT4 shall automatically generate default viewing screens for each RTU when the site is configured. These screens shall display all configured monitor and control points for an RTU in a real-time tabular and graphical format. Digital input and output points shall have their status displayed. Analog input and output points shall have their status displayed in text and bar graph format. Clicking a digital or analog monitor point shall generate a trend of the point’s activity over the last 24 hours. Clicking a digital or analog control point shall allow the user to set the point to a particular state or value. Screens Viewer HT4 shall include a tool for viewing custom-designed screens. Custom screens shall be capable of displaying the status of points and shall allow users to initiate controls. Custom screens shall be capable of displaying a series of snapshots from network camera(s) at a configured rate. Custom screens shall be capable of displaying data from different sites on the same screen. Custom screens shall be capable of displaying trends. Trend Viewer HT4 shall allow the user to view trends of historical values. The trend viewer shall be capable of displaying up to 12 variables on the same time/value axis. Trends containing multiple points can be displayed individually (single), each point in a separate panel (combined), or all points in the same panel (overlay). For each entry in the display list, the user shall be able to assign a given point name and color. A movable, vertical line shall act as a time cursor on the display. This cursor shall be moved by dragging the line to the left or right. The line shall select a particular date and time that corresponds with the values displayed at the right of the screen. The trend viewer shall be automatically updated as data arrives from the RTUs. Trend Viewer shall provide tools for: Zooming in (decreasing the time span) Zooming out (increasing the time span) Panning backward and forward in time Users shall have the option of: Setting a range for a trend (minimum and maximum values for the trend's y-axis). Applying a smoothing algorithm to create a smooth trend line. Adding reference lines (lines that represent critical values that are being monitored). Displaying a grid in the trend’s background. Manually setting the time span Defining default and global trend settings Users shall have the option of saving a trend (requires Configure Telemetry permission). Alarm Viewer HT4 shall have an alarm viewer that allows users to sort alarms by: Time alarm occurred RTU address User-defined name of point User-defined alarm name Status of alarm (ALARM, ACKNOWLEDGED, CLEARED) The alarm viewer shall present all alarms that are still unresolved (acknowledged or not) and all alarms that are resolved and unacknowledged. For each alarm, the alarm viewer shall display the date and time the alarm occurred, the user-name of the individual who acknowledged the alarm, and the date and time that the alarm was acknowledged. Camera Viewer HT4 shall be capable of displaying live video from network cameras installed on the same network as the HSS. System Reports Detail Report The system shall include a Detail Report. For the period specified by the user, the report shall display, print, or write to a file a list of all activity at a given RTU or a group of RTUs. The user shall have the option of specifying the report for one or more stations for any configured point type. When specifying the time period of the report, the user shall have the option of specifying: Range between two previous dates Range between two previous dates with an added daily time filter Current date Current date with an added daily time filter The report shall allow the user to specify: All the points at a remote terminal unit All the points on a module at a remote terminal unit A specific point at the remote terminal unit All the points in a defined grouping (keyword) The report shall include: User-defined name of the point The state or analog value of the point The time the point made the transition to the state or analog value Every point state change or analog value change for the specified period The time-stamp shall be the time of actual occurrence of the event and not the time the message was received. Report data shall be displayed in HTML format. The user shall be able to specify a text file format (.txt) or a spreadsheet file format (.csv) for export. Derived Flow Report The system shall include a Derived Flow Report. For the period specified by the user, the report shall display, print, or write to a file: The number of cycles of lift station pumps The average inflow in GPM or MGD The average outflow (pump rate) in GPM or MGD The total flow in gallons or million gallons The user shall have the option of specifying the report for one or more stations for configured derived flow points. When specifying the time period of the report, the user shall have the option of specifying: Range between two previous dates Range between two previous dates with an added daily time filter Current date Current date with an added daily time filter Derived flows calculated using pump capacities and run times are not acceptable because of the inaccuracy created by different head pressures. Derived flow calculations must use the “fill the bucket” method of calculating the flows. Report data shall be displayed in HTML format. The user shall be able to specify a text file format (.txt) or a spreadsheet file format (.csv) for export. Pump Activity Report The system shall include a Pump Activity Report. The report shall provide information on how long a digital point was on and how many times a digital point turned on, as well as the average and total accumulated time the point was on. Although this report shall be intended for pumping activity, it shall be capable of being used for other digital-type activity. For the period specified by the user, the report shall display, print, or write to a file: Number of cycles of the monitored function Average cycle of the monitored function Total on time of the monitored point Minimum and maximum amount of time the monitored function was on The user shall have the option of specifying the report for one or more stations for configured pump points. When specifying the time period of the report, the user shall have the option of specifying: Range between two previous dates Range between two previous dates with an added daily time filter Current date Current date with an added daily time filter Report data shall be displayed in HTML format. The user shall be able to specify a text file format (.txt) or a spreadsheet file format (.csv) for export. Pulse Report The system shall include a Pulse Report. The report shall provide a cumulative total or daily totals for the monitored function for the period specified by the user. For the period specified by the user, the report shall display, print, or write to a file the configured unit of measurement for each configured pulse accumulation point. The user shall have the option of specifying the report for one or more stations for configured pulse points. When specifying the time period for the report, the user shall have the option of specifying: Range between two previous dates Range between two previous dates with an added daily time filter Current date Current date with an added daily time filter Report data shall be displayed in HTML format. The user shall be able to specify a text file format (.txt) or a spreadsheet file format (.csv) for export. Analog (Flow) Report The system shall include an Analog Flow Report. For the period specified by the user, the report shall display, print, or write to a file: The total time the device was enabled The average flow in GPM or MGD The totalized flow in gallons or million gallons The user shall have the option of specifying the report for one or more stations for configured analog flow points. The user shall have the option of generating a cumulative total or daily totals for the specified time period. When specifying the time period for the report, the user shall have the option of specifying: Range between two previous dates Range between two previous dates with an added daily time filter Current date Current date with an added daily time filter Report data shall be displayed in HTML format. The user shall be able to specify a text file format (.txt) or a spreadsheet file format (.csv) for export. Radio Error Report The system shall include a Radio Error Report. For the period specified by the user, the report shall display, print, or write to a file a list of all radio errors that occurred. The report shall include the following: “No response” errors from a poll “Aborted response” errors from a poll “Bad response” errors from a poll (bad address format, bad message format, bad checksum or CRC) Total error count The online/offline status of the radio link to each remote terminal unit The total number of times the remote terminal unit was offline The total time the remote terminal unit was offline The user shall h Tools RTU Battery Test HT4 shall provide the capability of full-load testing of RTU batteries from any workstation computer via the SCADA system. Telemetry Traffic Tool HT4 shall provide users a tool for viewing radio and network communications. The telemetry traffic tool shall enable a user to: Determine the version of software that a particular station is running. Control a digital or analog point to a specific state or value. (Configuration permissions required.) Temporarily change the polling priority of a station or take it out of service. (Configuration permissions required.) View communications of all stations configured under the selected driver. Filter communications by station, module, or message. System Tool HT4 shall provide users who have high-level permissions the ability to: Stop and start telemetr

Plain text

OpenGov categories

  • 88500 · Water And Wastewater Treating Chemicals
  • 89000 · Water Supply, Groundwater, Sewage Treatment, And Related Equipment (Not For Air Conditioning, Steam Boiler, Or Laboratory Reagent Water)