State and local · OpenGov
Electrical Maintenance Services - Industrial
Description
The City of Sarasota is seeking a qualified Florida Licensed Electrical Contractor to provide technical and specialized industrial electrical maintenance services . The City of Sarasota Utilities Department operates and maintains water and wastewater treatment facilities and transmission and collection facilities within City limits and Sarasota County. These facilities range from 24-volt control systems to 13.2 kV (kilovolts) power distribution systems. The Contractor must demonstrate its expertise to provide technical and specialized industrial electrical maintenance services which are outlined in these specifications. The Contractor must also have the knowledge, skills and ability to properly diagnose, repair, maintain, rehabilitate and construct any of the Utilities Department's electrical components and systems. Scope of Work Scope I. MAINTENANCE AREAS: A. Power Distribution The bidder must have the knowledge, skills and ability to construct, maintain, diagnose and repair industrial plant electrical power components. These components will include, but not be limited to the following: Medium Voltage (1,000V– 35,000V) - delta wye systems, transformers, switching gear, motor starters and panels, protective devices, and many other similar devices. Low Voltage (0 – 1,000V) - motor control centers, motor controls, machine controls, automatic transfer switches, electrical machines, variable frequency drives, electrically operated valves, constant speed drives, valve actuators, limit switches, transformers, circuit breakers, motor starters, un-interrupted power supplies, emergency generator systems, lighting and receptacle circuits, battery chargers, AC (alternating current) and DC (direct current) circuits and many other similar electrical devices. II. SERVICE TYPES: A. Emergencies The bidder must have emergency services providing a 24-hour, 7-day a week response time. The bidder must be able to solve problems quickly, efficiently and with little disruption to the various plant processes. The bidder must have fully equipped vehicles and access to a warehouse of basic electrical supplies for use, 24 hours a day. The bidder must be able to have a journeyman or higher qualified technician, on site within TWO (2) hour s to start the electrical diagnostics due to our public safety emergencies. B. Inspection And Testing The bidder must have the experience to locate issues before they become a time and money concern, and which may slow or stop the plant's process. The bidder must be able to ensure that the City's equipment functions properly, such as calibrations, and complies with all electrical codes and standards. C. Troubleshooting and Diagnostic Testing The bidder must have the experience to complete diagnostic testing that shall include power monitoring, harmonic analysis and fault analysis. The bidder must have the ability to quickly and efficiently troubleshoot electrical problems when a component fails to work due to a loss of power. D. Maintenance And Repairs The bidder must have the ability to complete preventive, predictive and corrective electrical maintenance ranging in voltage from 12V to 13,200 kV. E. Rehabilitations The bidder must have the ability to get the job completed at the specified time and within the budget. F. AutoCAD Drawings The bidder must have in-house personnel with the ability to produce electrical drawings using AutoCAD (Automatic Computer-Aided Design) that will be used for record drawings. III. INSPECTION AND TESTING: A. Thermography Inspection The Contractor may be required to provide, either directly or through a sub-contractor, Thermography Inspections of the electrical distribution system, identifying equipment and connections operating above "normal" temperatures. “Normal” operating temperatures are defined in terms of rise above ambient temperature. A technician completing this work must be a Certified Level II Thermographer by Infraspection Institute or equivalent. To ensure that this individual can determine the relative criticality of hot spots that are located, he/she must have a minimum of three (3) years conducting infrared inspections and five ( 5) years of experience in electrical trade . A list of the panels and equipment shall be created by the City for the Contractor's use. The Contractor shall be required to propose an inspection report format and inspection log and shall be submitted with the scope of work and fee schedule proposal. The inspection form shall include, but not limited to, the following sections: Detailed location, date, and time. Detailed description of equipment Images and tables of deficiencies. Recorded thermal “hot spot” problems with date, time, temperature, scale of severity and priority. Two images shall be given for each problem, one color image showing the variation in temperatures and the other color image showing the piece of equipment. The severity of the thermal concern shall be identified as: (1) "immediate", (2) "next shut down", or (3) "as time permits". Other Testing and Inspections The City may require the Contractor to provide, either directly or through a sub-contractor, inspection and testing services by a certified representative on an as-needed basis, such as: Pad Mounted Transformer Oil Testing- The Contractor shall draw oil from 4160-volt and 13,200V transformers for ASTM (American Society for Testing and Materials) Oil Transformer Analysis. These annual tests show any changes and help prevent unanticipated failures by allowing planning for replacements. The Bid Costs shall be per transformer including labor, testing, and reports. These reports shall include historical data for graphing purposes. Medium Voltage Vacuum Breaker Inspection and Testing- The following inspections and testing shall be completed by the Contractor after the City has performed all switching and protective device settings. The Contractor shall provide to the City two copies of a report including test results to verify the condition of the equipment and recommendations for actions to be taken for each piece of equipment. These inspections and testing shall follow the National Fire Protection Association's (NFPA) 70B - Electrical Equipment Maintenance and the International Electrical Testing Associations - Maintenance Testing Specifications. C. Visual And Mechanical Inspection The Contractor may be required to provide, either directly or through a sub-contractor, the following: Verify documentation of equipment name plate data. Inspect for physical damage. Clean and lubricate operating mechanisms Inspect breaker for cell alignment, anchorage, and grounding. Verify operating mechanisms for alignment and clearances. Inspect the contact wear and measurement of critical distances, such as the contact gap in accordance with manufactu Introduction The City of Sarasota is seeking a qualified Florida Licensed Electrical Contractor to provide technical and specialized industrial electrical maintenance services . The City of Sarasota Utilities Department operates and maintains water and wastewater treatment facilities and transmission and collection facilities within City limits and Sarasota County. These facilities range from 24-volt control systems to 13.2 kV (kilovolts) power distribution systems. The Contractor must demonstrate its expertise to provide technical and specialized industrial electrical maintenance services which are outlined in these specifications. The Contractor must also have the knowledge, skills and ability to properly diagnose, repair, maintain, rehabilitate and construct any of the Utilities Department's electrical components and systems. The City's focus is to continuously supply our customers with water and sewer without interruptions during all conditions. The contract will be on an "as needed basis" for a three (3) year contract period with the option to be renewed for two (2) additional one (1) year periods upon mutual consent of both parties. The City of Sarasota reserves the right, to be used at its discretion and when in the best interest of the City, to award these services to more than one Contractor. The table below contains more detailed descriptions of the facilities that will require industrial electrical services. Florida Power and Light is the electrical supplier for the City. Plant Facilities Table Description Max Fault Protection (amp) Voltage/Phase Distance from Utilities Administration Bldg. (miles) Verna Well Field 1,000 13,200 / 3 20 Wastewater Treatment Plant 800 4,160 / 3 0.1 Downtown Well Field 150 480/ 3 3 Water Treatment Plant 3,200 480/ 3 0.1 Seawater Pumping Facility 200 480/ 3 2 Hi-Hat Reuse Facility 1,000 480/ 3 15 Dewatering Facility 900 480/ 3 0.1 Temple 800 480/ 3 3 Circus 400 480/ 3 3 Sanitary Sewer lift Stations Up to 1,200 480 /1 & 3 0.05 Release Project Date: November 4, 2026 Question Submission Deadline: November 18, 2026, 5:00pm Bid Submission Deadline: December 16, 2026, 2:30pm Procurement Contact: Helen Reed helen.reed@sarasotafl.gov City of Sarasota General Terms and Conditions SUBJECT TO THESE TERMS All responses are subject to the terms and conditions specified herein. Responses which do not comply with these conditions are subject to rejection. These Terms and Conditions are subject to the Order of Precedents in Section 2.3 of this document. DEFINITIONS “Response” – Will be considered the same as a bid, proposal, or any other terms used to describe the submittal of an electronic response to a solicitation. All responses shall be submitted electronically. “Respondent” – A bidder, proposer or any other individual or company that may submit a response to a CITY solicitation. “Solicitation” – A document or documents released by the City of Sarasota (CITY) for the purpose of obtaining goods or services. Considered the same as an Invitation to Bid (ITB), Request for Proposal (RFP), Request for Qualifications (RFQu), Invitation to Negotiate (ITN), or any other title designated by the CITY to solicit goods or services. ORDER OF PRECEDENTS If a conflict arises between these Terms and Conditions, the following ORDER OF PRECEDENTS will apply: Florida State Law as applied to Municipal Purchasing in accordance with Title XIX, “Public Business”, Chapter 287 “Procurement of Personal Property and Services” City of Sarasota Procurement Code Special Conditions and Supplemental Instructions Detailed Scope of Work Solicitation specific Terms and Conditions (RFP, Bid, Construction, etc.) These Terms and Conditions CONTRACT FORMS Any agreement, contract, or Purchase Order resulting from the acceptance of a response shall be in a form as approved by the CITY. RESPONSE DELIVERY AND SUBMISSION REQUIREMENTS AND COMMUNICATIONS Only electronic responses will be submitted to the CITY via the CITY’s online solicitation program. If specified as being allowed, large-file backup documentation that is required, such as plans or concept drawings, may be submitted as a single hard copy with an electronic copy on a flash drive. The electronic copy should include one consolidated PDF file that contains the entire response. Confidential Response Information – If any information is submitted with the solicitation documents that is deemed “Confidential” by the Respondent, then the Respondent must stamp those pages of the response in the PDF file that are considered "Confidential." Respondent must provide documentation as to why these documents should be declared confidential and/or exempt in accordance with exemptions provided under Florida's public records laws. Respondent will be responsible for proving confidentiality and exemptions upon the CITY receiving any valid public records request. The Respondent will be responsible for all costs involved in that process. In accordance with Section 2-361 of the CITY Code of Ordinances, upon receipt of a response to a solicitation, the CITY will not be aware that a bid, proposal, or other response contains “Confidential” or exempt information. Therefore, bidders, proposers or other persons or entities responding to CITY solicitations must specifically and clearly identify all portions of their responses which are believed to be a trade secret, as defined by the law, and must, as to each such designation, provide the basis upon which the designated information is a confidential and exempt trade secret. The mere designation of an entire submission as "Confidential" or “Exempt” will be insufficient to comply with this requirement. Absent some unusual justification, a bidder's or proposer's contract price shall not constitute a trade secret. Solicitation Opening Solicitation responses shall be publicly opened on the date and at the time specified in the online solicitation. It is the Respondent's responsibility to ensure that their response is uploaded before the deadline date and time. Responses, which for any reason are not uploaded on time, will not be considered. Offers by fax, mail, private carrier or telephone are not acceptable unless otherwise specified. A response may not be altered after the closing of the solicitation. If hard copies of the Solicitation response are requested, Solicitation documents shall be sealed in an envelope or packaging and shall be clearly marked with the words "Solicitation Response Documents" and show the solicitation name and number, name and address of the Respondent, and date and time of the scheduled opening. All solicitation documents shall be submitted in writing, signed by the Respondent or the Respondent's duly authorized agent, and shall be mailed or delivered to the office of the Procurement Official prior to the date and time scheduled for the opening of responses. The Procurement Official, or designee shall publicly display solicitation responses submitted online. A Respondent may withdraw a response any time prior to the close of the solicitation. After solicitations are closed, but prior to award of the contract by the City Commission or Charter Official, the City Commission or Charter Official may allow the withdrawal of a response because of the mistake of the Respondent in the preparation of the response document. In such circumstances, the decision of the City Commission or Charter Official to allow the response withdrawal, although discretionary, shall be based upon a finding that the Respondent, by clear and convincing evidence, has met each of the following four tests: The Respondent acted in good faith in submitting the response, The mistake in response preparation was of such magnitude that to enforce compliance by the Respondent would cause severe hardship on the Respondent, The mistake was discovered and was communicated to the CITY prior to the City Commission having formally awarded the contract. CLARIFICATION AND ADDENDA Questions and requests for clarification should be submitted through the CITY’s online solicitation system. Answers to questions and/or addenda are issued through the CITY’s online solicitation system. If for some reason the CITY issues a call for hard copy responses, then information or questions concerning this solicitation may also be submitted to the City of Sarasota Purchasing Division, 1565 First Street, Room 205, Sarasota, Florida 34236, phone number (941) 263-6452, unless otherwise noted in the specifications. After the issuance of the solicitation, prospective Respondents or any agent, representative or person acting at the request of such Respondent shall not have any contact, communicate with or discuss any matter relating in any way to the solicitation with any Commissioner, agent or employee of the CITY other than the Procurement Official or their designee. This prohibition begins with the issuance of any solicitation and ends upon execution of the final contract or when the solicitation has been canceled or upon determination by the Procurement Official that a “Cone of Silence” is in effect for the solicitation or upcoming solicitation. If it is determined that improper communications were conducted, the Respondent may be declared not responsible. Detailed specifications describe the commodities, services, or construction services to be acquired by the CITY. To be considered for award, a response must comply in all material respects with the specifications. No alternate responses or deviations from the specifications will be accepted unless requested in the specifications or response form and as approved through written addendum. Each Respondent shall examine all solicitation documents and shall judge all matters relating to the adequacy and accuracy of such documents. Any inquiries, suggestions or requests concerning interpretation, clarification or additional information pertaining to the solicitation shall be made in writing through the online solicitation software Q&A portal prior to the date when questions are due. The CITY shall not be responsible for oral interpretations given by any CITY employee, representative, or others. Except at the pre-solicitation conference, every request for interpretation of the meaning of the plans, specifications, or any contract documents, or for correction of any apparent ambiguity, inconsistency or error therein, shall be in writing, preferably asked within the CITY’s electronic bidding system, or addressed to the Procurement Official or designee. The issuance of the Questions and Answers in the CITY’s online solicitation system, or a written addendum, added within the CITY’s online solicitation system, by the CITY’s Purchasing Division is the only official method whereby interpretation, clarification or additional information can be given. If any addenda are issued to this solicitation, the CITY will attempt to notify all prospective Respondents who have secured same; however, it shall be the responsibility of each Respondent, prior to submitting their response, to determine if addenda were issued and to make such addenda a part of their response. Acknowledgement of addenda receipt will be noted by each Respondent within the online solicitation software. Failure to acknowledge addenda may deem your submittal nonresponsive. Should the Respondent find discrepancies in or omissions from the drawings and specifications, scope of work, or other documents attached hereto, or should they be in doubt as to the meaning, they should at once contact the Purchasing Division and obtain clarification prior to submitting a response. Governmental Restrictions In the event any governmental restrictions may be imposed which would necessitate alteration of the material, quality, workmanship or performance of the items offered on this solicitation prior to their delivery, it shall be the responsibility of the Respondent to notify the Purchasing Division at once, indicating in their letter or email the specific regulation which required an alteration. The CITY reserves the right to accept any such alteration, including any price adjustments occasioned thereby, or to cancel the solicitation or contract at no further expense to the CITY. SOLICITATION/RESPONSE EXPENSES Respondent shall bear all costs and expenses incurred in developing, preparing, and submitting responses to this solicitation. IRREVOCABLE OFFER Any response may be withdrawn until the date and time set for closing of the responses to this solicitation. All withdrawals must be requested in writing via email, or letter, requesting removal from the CITY’s electronic solicitation system. Any response not so withdrawn shall, upon opening, constitute an irrevocable offer for a period of one hundred and twenty (120) days to sell to the CITY the goods or services set forth in the attached specifications. Failure to respond, either by submitting a bid or proposal, or by submitting a “NO BID” Statement elimin
Published attachments
OpenGov categories
- 72154300 · Motive and electrical power generation equipment maintenance and repair services
- 73152108 · Electrical equipment maintenance and repair service
- 81101701 · Electrical engineering services
- 81102400 · Electrical power transmission engineering