State and local · OpenGov
Environmental Sampling And Analytical Laboratory Services
Description
The City of Bartow is soliciting bids from qualified and certified laboratory service to perform wastewater sampling, laboratory analysis, and related analytical services for the City’s Water and Wastewater Treatment Facilities. Services will be required at the Water Treatment Plant (WTP), located at 2500 US Highway 17 N, Bartow , and the Wastewater Treatment Plant (WWTP), located at 2505 East Wabash Street, Bartow, FL . The awarded vendor shall perform all services in full compliance with the Florida Department of Environmental Protection (FDEP) requirements, the City’s wastewater permit, applicable United States Environmental Protection Agency (EPA) regulations, and all approved analytical methods and sampling schedules established by the City. The scope of services under this Invitation to Bid (ITB) may include, but shall not be limited to: collection of wastewater, influent, effluent, and sludge/biosolids samples; laboratory analysis for all parameters required under the City’s operating permits; provision of analytical results and laboratory reports within mandated reporting timeframes; immediate notification to the City of any exceedances of permit limits; supply of all required sample containers, preservatives, and labels; proper sample preservation, handling, transportation, and maintenance of complete chain‑of‑custody documentation. The awarded laboratory shall provide accurate, reliable, and timely analytical services and coordinate closely with City staff to ensure that all sampling and testing activities are completed in accordance with all regulatory, permit, and operational deadlines. SCOPE OF WORK Overview The City of Bartow is soliciting bids from qualified and certified laboratory service to perform wastewater sampling, laboratory analysis, and related analytical services for the City’s Water and Wastewater Treatment Facilities. Services will be required at the Water Treatment Plant (WTP), located at 2500 US Highway 17 N, Bartow , and the Wastewater Treatment Plant (WWTP), located at 2505 East Wabash Street, Bartow, FL . The awarded vendor shall perform all services in full compliance with the Florida Department of Environmental Protection (FDEP) requirements, the City’s wastewater permit, applicable United States Environmental Protection Agency (EPA) regulations, and all approved analytical methods and sampling schedules established by the City. The scope of services under this Invitation to Bid (ITB) may include, but shall not be limited to: collection of wastewater, influent, effluent, and sludge/biosolids samples; laboratory analysis for all parameters required under the City’s operating permits; provision of analytical results and laboratory reports within mandated reporting timeframes; immediate notification to the City of any exceedances of permit limits; supply of all required sample containers, preservatives, and labels; proper sample preservation, handling, transportation, and maintenance of complete chain‑of‑custody documentation. The awarded laboratory shall provide accurate, reliable, and timely analytical services and coordinate closely with City staff to ensure that all sampling and testing activities are completed in accordance with all regulatory, permit, and operational deadlines. Background A 4.0 Million Gallons per Day (MGD) annual average daily flow SBR wastewater treatment facility currently treats wastewater generated within Bartow and from interconnected regional systems serving Eagle Lake and Polk County. Required responsibilities include ongoing operation, maintenance, monitoring, and fulfillment of all regulatory and permit requirements. Potable water production is supported by an 8.75 MGD Lime Softening Water Treatment Plant, which also relies on accurate sampling and laboratory analysis to maintain regulatory compliance. Qualifications Bidders must meet the following minimum qualifications to be considered responsive and responsible: The Company submitting a bid must have been in business under the same name & TIN/FEIN number for the past Five (5) years . The Company shall hold proper licensing and authorization to conduct business in the State of Florida throughout the duration of the Agreement. In order to do business with the City of Bartow, businesses based within the City limits of the City of Bartow shall furnish a copy of the most recent City of Bartow Business/Occupational License in which can be obtained from https://www.cityofbartow.net/departments-services/city-clerk-public-records/business-tax-receipt-occupational-licenses-applications-payments . For businesses based outside the City limits of the City of Bartow but are based in Polk County or those businesses based outside Polk County shall furnish a copy of the most recent Polk County Business/Occupational License in which may be obtained from https://www.polktaxes.com/services/local-business-taxes/ . Company shall also be licensed to perform the type of work stated in this solicitation. Specially company must hold a EPA, Florida Department of Environmental Protection, and the Florida Department of Health Laboratory Certification . Indicate registration, license numbers or certificate numbers for the business or professions which are the subject of this Bid. • The laboratory shall be certified by the Florida Department of Health (DOH) for all analyses listed in this ITB, utilizing test methods required by DEP, EPA, or other applicable regulatory agencies. • The laboratory shall meet all current National Environmental Laboratory Accreditation Program (NELAP) requirements for the parameters tested. • The laboratory shall maintain a DEP and DOH‑approved Quality Assurance/Quality Control (QA/QC) Plan and Program . Documentation must be provided upon request. The Contractor shall provide three (3) references from clients for whom the bidder has served as the prime contractor on projects of similar size and scope within the p ast five (5) years , with at least 2 years with other government municipalities . Please refer to the Reference Form provided under the Vendor Submittal Forms. Minimum Required Services 1. Laboratory Accreditation 2. Licenses & Certifications 3. Experience 4. Qualified Personnel 5. Ability to Provide Routine & Emergency Services 6. Required Equipment & Materials 7. Insurance Requirements Detailed Scope of Services The intent of this Invitation to Bid (ITB) is to establish a contract with a qualified and certified laboratory to provide environmental sampling, sample pickup, transportation, analytical testing, reporting, and emergency response services on an as‑needed basis. All work shall comply with EPA, American Society for Testing and Materials ( ASTM), FDEP, and all applicable regulatory requirements. The successful bidder shall furnish all labor, materials, equipment, sample containers, preservatives, transportation, and supplies necessary to perform the services described herein. Sample Collection The contractor shall perform sampling activities in accordance with all applicable regulatory standards and the City’s operational requirements. Sample collection services shall include, but are not limited to, the following: Field Sampling Activities • Collect routine, special, and compliance‑related samples as directed by the City. • Collect water samples from surface water, groundwater, reclaimed water, drinking water systems, and wastewater treatment locations. • Collect wastewater influent, effluent, biosolids, and other site‑specific matrices at City facilities. • Collect soil and biological samples when required. • Collect industrial user samples and other Pretreatment Program samples at designated discharge points. Sampling Protocols & Standards • Perform all sampling in accordance with EPA, ASTM, DEP, and DOH protocols. • Follow City-specified sampling techniques including grab, composite, time‑weighted, or flow‑proportional sampling. • Ensure preservatives, containers, and sampling media comply with method‑specific requirements. Sample Handling and Preservation • Properly preserve all samples immediately upon collection using EPA‑approved preservatives and cooling procedures. • Maintain sample temperature requirements (e.g., ≤ 6°C) during collection and transport. • Ensure appropriate labeling, documentation, and identification of all samples. Chain‑of‑Custody Requirements • Complete chain‑of‑custody (COC) documentation in full for every sample. • Transfer custody only to authorized laboratory personnel. • Maintain continuous COC from sample collection to laboratory receipt. Sample Transport • Transport samples in secured, leak‑proof, temperature‑controlled coolers. • Deliver samples to the certified laboratory immediately following pickup or within holding time limitations. • Provide a record of cooler receipt and confirmation of sample integrity. Sampling Supplies and Equipment • Provide all sample bottles, preservatives, ice, coolers, labels, and materials required for sampling. • Maintain sampling equipment (e.g., composite samplers, pumps, tubing) in clean, calibrated condition. • Provide alternate sampling equipment when required by method or location. Coordination and Site Access • Coordinate sample collection activities with designated City staff to ensure safe and timely access to sampling locations. • Follow all City safety requirements, site access procedures, and hazard communication protocols. • Notify the City immediately of any site conditions that may affect sampling activities. Sample Pickup Schedule Requirement 1. Routine Pickup Availability The contractor must be able to support routine pickups during the City’s operating hours. At a minimum, the contractor shall: • Be available for pickups between 7:00 a.m. and 5:00 p.m. , Monday through Friday. • Maintain sufficient staff to accommodate same‑day or next‑day pickups when requested. • Ensure continuity of service during staff absences through backup personnel. 2. City‑Issued Pickup Notifications The City will provide pickup instructions that include: • Sample type(s) • Pickup location(s) • Required pickup date • Required pickup window • Any special handling or preservation instructions The contractor must confirm receipt of the pickup request within four (4) hours of notification. 3. Response to Routine Pickup Requests Upon receiving a routine pickup request: • The contractor must confirm availability and expected arrival time. • Routine pickups must be completed on the same business day unless otherwise directed by the City. • All samples shall be transported to the laboratory immediately after collection or pickup. 4. Equipment & Resource Requirements The contractor shall maintain: • Adequate vehicles suitable for temperature‑controlled sample transport • Sample coolers, ice, preservatives, and containers • Chain‑of‑custody forms • Backup drivers or couriers to ensure timely service • Inventory of EPA‑approved sampling supplies 5. Coordination Expectations The contractor shall: • Coordinate closely with designated City personnel each day • Notify the City immediately of delays, issues, or conflicts • Keep contact information updated and provide a dedicated communication line for pickups • Maintain the ability to handle multiple pickup locations in a single day when required Sample Analysis 1. Analytical Methods and Standards The laboratory shall: • Use approved analytical methods from EPA, ASTM, Standard Methods, or applicable DEP/DOH regulatory requirements. • Apply the correct analytical method based on matrix type (e.g., water, wastewater, biosolids, soil, reclaimed water). • Maintain method‑specific detection limits and reporting limits that meet or exceed regulatory thresholds. • Ensure method documentation is available for City review upon request. 2. Analytical Capabilities by Sample Type The laboratory shall provide testing for: • Wastewater influent and effluent parameters • Biosolids, sludge, and residuals • PFAS compounds in water and solids • Drinking water parameters for the City’s water treatment plant • Reclaimed water and surface water samples • Industrial Pretreatment Program pollutants (metals, toxics, organics, etc.) • Emergency spill response pollutants, including bacteriological indicators 3. Quality Control and Validity of Results The laboratory shall: • Perform internal QC procedures including blanks, duplicates, spikes, and calibration checks. • Maintain and calibrate equipment per manufacturer and accreditation requirements. • Document any deviations, potential contamination, or sample condition issues. • Notify the City immediately if any sample cannot be analyzed or if holding times are exceeded. 4. Turnaround Time Requirements The laboratory shall meet the turnaround times corresponding to each service category included in the Pricing Table, including: • Routine analysis turnaround times • Emergency 24‑hour or faster turnaround times where required • PFAS turnaround times • Pretreatment analytical timelines for compliance reporting Turnaround expectations shall begin at the time of sample receipt at the laboratory. 5. Sample Receipt and Laboratory Handling Upon receiving samples, the laboratory shall: • Verify chain‑of‑custody documentation • Confirm correct preservatives and temperature • Document any discrepancies immediately to the City • Log samples into the laboratory information system • Begin processing within required holding times 6. Analytical Deliverables All analytical results must include: • Parameter tested • Analytical method used • Reporting limit • Result with units • QC summaries • Sample collection information (date, time, sampler, location) • Any analytical qualifications or flags • Electronic Data Deliverables (EDDs) in City‑specified format Emergency Sewer Spill Sampling 1. Emergency Sample Collection • Collect wastewater, surface water, stormwater, sediment, and any other environmental samples required by the City or regulatory agencies during an emergency event. • Perform grab or composite sampling, as appropriate for the incident. • Conduct field measurements as needed (e.g., pH, chlorine, dissolved oxygen, temperature). • Provide all necessary emergency sample containers, preservatives, labels, and supplies. 2. Sample Handling and Preservation • Immediately preserve samples in accordance with method‑specific requirements. • Maintain required temperature control (e.g., ≤6°C) during transport. • Ensure proper labeling, identification, and documentation for all samples collected during emergency events. • Complete chain‑of‑custody forms accurately and securely transfer custody to laboratory personnel. 3. Transportation and Laboratory Receipt • Transport emergency samples directly to the laboratory using temperature‑controlled coolers. • Ensure samples are delivered within regulatory holding time limits. • Notify the City immediately if any sample is compromised or cannot be analyzed. 4. Analytical Services • Perform analytical testing required by FDEP or other regulatory authorities for spill reporting. • Analyze parameters relevant to emergency events, which may include bacteriological indicators, nutrients, metals, organics, PFAS, or other contaminants as directed. • Prioritize emergency samples to ensure compliance with regulatory reporting requirements. • Provide complete analytical documentation and summary of results. 5. Communication and Coordination • Maintain continuous communication with designated City personnel during the emergency response. • Provide updates regarding sample collection, laboratory receipt, analysis progress, and report completion. • Immediately communicate any analytical result that may indicate a regulatory exceedance or public health concern. Emergency Response Requirements The contractor shall maintain the capability to respond to emergency sampling events, including sewer spills and sanitary sewer overflows (SSOs), 7 days per week, including weekends and City‑recognized holidays . The contractor must meet the following minimum emergency response timelines: Initial Notification Acknowledgment: The contractor shall acknowledge receipt of an emergency request within 2 hours of notification by the City. On‑Site Response Time: The contractor shall arrive at the designated City location within five (5) hours of the City’s request for emergency sampling, unless otherwise directed by the City. Sample Collection and Transport: Emergency samples shall be collected, preserved, and transported to the laboratory immediately upon arrival , following EPA and FDEP emergency sampling protocols. Analytical Turnaround Time: Emergency analytical results required for regulatory reporting shall be provided to the City within 72 hours , or sooner if required under applicable FDEP regulations. Communication Requirements: The contractor shall provide real‑time updates to City personnel regarding: • sample collection status, • laboratory receipt, • expected analysis completion time, • confirmation of delivered results. After‑Hours Availability: The contractor shall maintain an emergency contact number staffed or monitored 24/7 . Emergency Supplies: The contractor shall maintain sufficient emergency sampling kits, containers, preservatives, and equipment to support immediate deployment. Emergency response services shall be billed in accordance with the Emergency Pricing section of the Pricing Table. Pretreatment Program Services 1. Industrial User Sampling • Conduct sampling at permitted industrial user facilities and other regulated discharge locations identified by the City. • Collect wastewater samples directly from industrial discharge points, manholes, or sampling ports as applicable. • Follow all sampling procedures specified in industrial user permits, the City’s Pretreatment Program requirements, and applicable regulatory guidelines. 2. Grab and Composite Sampling • Perform grab sampling for parameters requiring discrete sample collection. • Perform time‑weighted or flow‑proportional composite sampling when required for compliance monitoring or industrial user permit conditions. • Provide and operate composite samplers when required, including equipment setup, calibration, maintenance, and retrieval. 3. Analytical Testing for Pretreatment Program Pollutants The contractor shall conduct analytical testing for parameters required under: • Industrial user discharge permits • Local limits • 40 CFR Part 403 and applicable federal Pretreatment regulations • DEP and EPA compliance requirements Parameters may include, but are not limited to: • Metals • Organics • Toxic pollutants • Conventional pollutants (e.g., BOD, TSS, pH, oil & grease) • Site‑specific permit-required analytes 4. Sampling to Support Investigations • Conduct sampling related to suspected unauthorized discharges, illicit connections, or noncompliance investigations. • Collect follow‑up or confirmation samples as directed by the City. 5. Reporting and Documentation Requirements • Provide analytical reports clearly identifying: – industrial user location – date and time of collection – sampling method (grab or composite) – analytical results, including reporting limits – QA/QC data • Provide electronic data deliverables (EDDs) in City‑specified formats suitable for Pretreatment Program records. &
OpenGov categories
- 96895 · Wastewater Treatment Plant, Operations, and Testing
- 96896 · Water and Wastewater Treatment Services
- 98900 · Sampling And Sample Preparation Services (For Testing)
- 98924 · Chemical Sampling and Preparation Services
- 98975 · Soil Sampling and Preparation Services
- 98991 · Water Sampling and Analysis Services