State and local · OpenGov
Fire Extinguisher Inspection, Maintenance, Testing, Repair Services and Parts
Description
The City of Pasadena Department of Public Works, Building Systems and Fleet Management Division (BSFMD) is seeking a qualified vendor to provide comprehensive fire extinguisher inspection, maintenance, testing, certification, repair, recharging, hydrostatic testing, replacement, and related parts and support services for fire extinguishers located throughout City-owned facilities, fleet vehicles, and equipment. Services shall be provided on an as-needed and scheduled basis and performed in accordance with the latest editions of National Fire Protection Association (NFPA) 10, Office of the State Fire Marshal (OSFM) requirements, Occupational Safety and Health Administration (OSHA), California Occupational Safety and Health Administration (Cal/OSHA), manufacturer recommendations, and all applicable federal, state, and local regulations. The resulting contract will ensure fire extinguishers remain properly inspected, maintained, tested, and ready for emergency use while minimizing operational disruptions to City facilities and fleet operations. Bid Specifications Purpose The purpose of this solicitation is to establish a contract with a qualified Contractor to provide as-needed fire extinguisher inspection, maintenance, testing, certification, repair, recharging, hydrostatic testing, replacement, and related support services. The contract will ensure the City has access to qualified services necessary to maintain fire extinguishers in accordance with applicable codes, regulations, and industry standards throughout the contract term. Scope of Work The Contractor shall provide comprehensive, as-needed fire extinguisher inspection, maintenance, testing, certification, repair, recharging, hydrostatic testing, replacement, and related support services for portable fire extinguishers located throughout City-owned facilities, fleet vehicles, and equipment. The Contractor shall furnish all labor, supervision, transportation, vehicles, tools, testing equipment, replacement parts, extinguishing agents, materials, permits, certifications, documentation, disposal services, and incidental items necessary to perform the required services in accordance with the requirements of this solicitation. Services to be provided under this contract include, but are not limited to: 7.2.1. Annual fire extinguisher inspections 7.2.2. Routine maintenance and servicing 7.2.3. Six-year internal maintenance, where applicable 7.2.4. Hydrostatic testing, where required 7.2.5. Fire extinguisher recharging 7.2.6. Inspection, diagnosis, and repair of defective fire extinguishers 7.2.7. Replacement of approved repair components 7.2.8. Replacement of condemned or non-repairable fire extinguishers upon City authorization 7.2.9. Furnishing replacement fire extinguishers, mounting brackets, cabinets, vehicle mounting hardware, and related accessories, when requested by the City 7.2.10. Electronic inspection reports and service documentation 7.2.11. Routine, urgent, and emergency service requests 7.2.12. Proper disposal of condemned fire extinguishers in accordance with applicable laws and regulations The City currently maintains portable fire extinguishers at various municipal facilities, fleet vehicles, and equipment. The quantities, service locations, and inspection schedules identified in this solicitation are estimates only and may increase, decrease, or change throughout the contract term. The City reserves the right to modify service locations, inspection schedules, and quantities as operational needs require. Annual Inspection and Maintenance Requirements The Contractor shall perform annual inspections and routine maintenance of all portable fire extinguishers in accordance with the latest editions of NFPA (National Fire Protection Association) 10, manufacturer recommendations, and all applicable federal, state, and local regulations. All inspections shall be performed by properly licensed and qualified technicians. At a minimum, the annual inspection and maintenance shall include: General Requirements The Contractor shall perform annual inspections of all portable fire extinguishers identified by the City. Routine maintenance shall be completed during the inspection whenever practical. Fire extinguishers determined to be damaged, discharged, expired, or otherwise unsuitable for continued service shall be documented and reported to the City's designated Contract Administrator in accordance with this solicitation. Visual Inspection The Contractor shall inspect each fire extinguisher to verify, at a minimum: The fire extinguisher is installed in its designated location and is readily visible and accessible Access to the fire extinguisher is unobstructed The fire extinguisher classification is appropriate for the hazard being protected Manufacturer labels, operating instructions, and safety markings are legible The extinguisher is properly mounted using an approved bracket or cabinet The inspection tag is current and accurately reflects the service performed. Mechanical Inspection The Contractor shall inspect the condition and operation of the fire extinguisher, including but not limited to: Pressure gauge and operating pressure Cylinder shell for dents, corrosion, leakage, or other physical damage Valve assembly Carrying handle and operating lever Safety pin and tamper seal Hose, nozzle, horn, and hose retention devices Threads, fittings, and connections Condition of all external components. Routine Maintenance The Contractor shall perform all routine maintenance necessary to return the fire extinguisher to proper operating condition, including but not limited to: Replace tamper seals and inspection tags Clean exterior surfaces of the extinguisher Replace worn or damaged approved components Recharge extinguishers when required Verify six-year internal maintenance and twelve-year hydrostatic testing intervals, where applicable Return the extinguisher to its designated mounting location following completion of service. Deficiencies Any fire extinguisher found to be damaged, discharged, expired, non-compliant, or otherwise unserviceable shall be immediately reported to the City’s Contract Administrator. The Contractor shall provide written recommendations identifying the deficiency, recommended corrective action, and estimated cost. No repairs beyond routine annual inspection and maintenance shall be performed without prior City authorization unless necessary to address an immediate life safety concern. Documentation Upon completion of each inspection, the Contractor shall provide documentation identifying each fire extinguisher inspected, the services performed, deficiencies identified, replacement parts used, recharge services performed, testing completed, and recommendations for repair or replacement. Inspection records shall be submitted electronically in a format acceptable to the City and shall accompany the Contractor’s invoice. Specialized Maintenance and Testing Services The Contractor shall provide specialized fire extinguisher maintenance and testing services as required by NFPA 10, manufacturer recommendations, applicable federal and state regulations, and the City’s operational requirements. These services shall be performed only by properly trained and qualified personnel using approved equipment and materials. Recharge Services Fire extinguishers requiring recharge due to discharge, inspection, maintenance, or repair shall be serviced using extinguishing agents and materials that are compatible with the original manufacturer’s specifications. Recharge services shall include all labor, replacement seals, O-rings, tamper seals, inspection tags, and incidental materials necessary to restore the fire extinguisher to proper operating condition. Recharge services shall not be performed unless authorized by the City or required to restore an extinguisher that has been discharged or opened during maintenance. Six-Year Internal Maintenance When required by NFPA 10, the Contractor shall perform six-year internal maintenance (tear-down) of applicable fire extinguishers. Internal maintenance shall include, at a minimum: Internal examination of the cylinder and valve assembly Inspection of internal components for corrosion, contamination, wear, or damage Replacement of required O-rings, valve stem seals, gaskets, and other approved service components Verification that the extinguisher remains suitable for continued service Reassembly, recharge, testing, certification, and documentation in accordance with NFPA 10 and manufacturer recommendations Internal maintenance shall only be performed on extinguishers that pass the required visual inspection. The Contractor shall immediately notify the City if any extinguisher fails inspection or is determined to be unsafe or unsuitable for continued service. Hydrostatic Testing The Contractor shall perform hydrostatic testing at the intervals required by NFPA 10, U.S. Department of Transportation (DOT) regulations, manufacturer recommendations, and other applicable requirements. Hydrostatic testing shall include: Transportation of extinguishers requiring off-site testing, when necessary Performance of hydrostatic testing by appropriately licensed and qualified personnel Replacement of required service components following testing Recharge and recertification of the extinguisher following successful completion of the test Documentation of all testing results Fire extinguishers that fail hydrostatic testing shall not be returned to service. The Contractor shall provide written notification identifying the failed extinguisher, reason for failure, and recommendations for replacement. Off-Site Services Certain specialized services, including hydrostatic testing and other maintenance that cannot reasonably be completed on-site, may be performed at the Contractor’s facility. Fire extinguishers removed from City facilities or fleet operations shall be returned within two (2) weeks unless otherwise approved by the City. Whenever practical, the Contractor shall provide temporary loaner fire extinguishers of equal or greater rating to maintain continuous fire protection while City-owned extinguishers are being serviced. City Authorization Repairs, specialized maintenance, hydrostatic testing, replacement fire extinguishers, or additional services beyond routine annual inspection shall require prior authorization from the City’s designated Contract Administrator unless immediate action is necessary to eliminate an imminent life safety hazard. Service Locations and Scheduling The Contractor shall coordinate all services with the City's designated Contract Administrator. Services shall be performed at City-owned facilities, fleet vehicles, and equipment located throughout the City of Pasadena. The City reserves the right to modify service locations, inspection schedules, and quantities throughout the contract term as operational needs require. City Facilities Building fire extinguisher inspections shall generally be performed on-site at City-owned facilities in accordance with the City's annual inspection schedule. A list of City facility locations, annual inspection schedule, and geographic quadrant assignments are provided in the solicitation attachments for reference. The Contractor shall coordinate building access and inspection scheduling with the City's designated Contract Administrator to minimize disruption to City operations. Fleet Vehicles and Equipment Fleet fire extinguisher services shall generally be performed at the following address unless otherwise directed by the City's designated Contract Administrator: City of Pasadena – City Yards 323 W. Mountain Street Pasadena, CA 91103 The Contractor shall coordinate service scheduling with Fleet personnel to minimize vehicle downtime and maintain operational readiness. Off-Site Services When specialized maintenance or testing requires fire extinguishers to be removed from service, the Contractor shall coordinate the removal and return of the fire extinguishers with the City’s designated Contract Administrator. When approved by the City and necessary to maintain continuous fire protection, the Contractor shall provide temporary loaner fire extinguishers of equal or greater classification and capacity while City-owned fire extinguishers are undergoing off-site service. Scheduling Routine inspections and maintenance shall be scheduled in coordination with the City’s designated Contract Administrator. The City reserves the right to modify inspection schedules, service locations, building assignments, and quantities as operational needs require. The Contractor shall make reasonable efforts to accommodate schedule adjustments requested by the City. Reporting and Documentation Requirements The Contractor shall maintain complete and accurate service records for all work performed under this contract. Inspection Reports Upon completion of each service visit, the Contractor shall provide an electronic inspection report acceptable to the City. At a minimum, each report shall include: Service date Building, facility, or vehicle identification Asset number and/or manufacturer barcode Type and size of fire extinguisher Services performed Recharge services completed Hydrostatic testing performed Parts replaced Quantities Technician name Recommendations for repair or replacement Deficiencies identified Inspection status Failed Equipment Fire extinguishers that fail an inspection, internal maintenance, or hydrostatic test shall be documented in a separate report identifying: Asset identification Reason for failure Recommended corrective action Estimated replacement cost, if applicable Invoicing Invoices shall include sufficient detail to verify services performed and shall correspond to the inspection reports submitted for the same service period. The City reserves the right to reject invoices containing unauthorized work or insufficient documentation. Performance Standards The Contractor shall perform all services in a professional, timely, and workmanlike manner. At a minimum, the Contractor shall: Schedule routine service requests within two (2) weeks of notification Respond to urgent service requests within forty-eight (48) hours Coordinate emergency service requests immediately upon notification by the City Ensure technicians wear company uniforms and photo identification while performing services Check in with the designated City representative before beginning work at each location Exercise reasonable care to protect City property during the performance of services Maintain service vehicles with sufficient tools, equipment, replacement parts, and extinguishing agents to complete routine inspections and repairs during scheduled service visits Complete work during normal City business hours unless otherwise approved by the City Minimize disruptions to City operations while performing services Promptly correct deficiencies identified by the City at no additional cost when the deficiencies result from the Contractor’s workmanship or failure to comply with the contract requirements Minimum Product Requirements All replacement fire extinguishers, repair components, recharge agents, accessories, and related materials furnished under this contract shall meet or exceed the minimum requirements identified below. General Requirements The Contractor shall provide products and materials that are: New, unused, and free from defects Suitable for the intended application and compatible with the existing fire extinguisher Compliant with the latest editions of NFPA 10, applicable manufacturer specifications, and all federal, state, and local regulations UL listed or otherwise certified, where applicable Free from damage, excessive wear, corrosion, contamination, or deterioration Replacement Parts Replacement parts shall: Be original equipment manufacturer (OEM) parts or equivalent components that meet or exceed OEM specifications Be compatible with the make and model of the fire extinguisher being serviced Include all necessary hardware, seals, gaskets, O-rings, valve stem seals, tamper seals, inspection tags, and related components required to complete the repair Be installed in accordance with manufacturer recommendations Recharge Materials Recharge agents shall: Meet the manufacturer’s specifications for the specific fire extinguisher being serviced Be appropriate for the extinguisher classification and hazard rating Be uncontaminated and stored in accordance with manufacturer recommendations and applicable safety regulations Replacement Fire Extinguishers When replacement fire extinguishers are authorized by the City, the Contractor shall furnish extinguishers that: Meet the required fire classification and capacity for the intended application Are listed and labeled by an approved nationally recognized testing laboratory Include all required operating instructions, safety labels, and certification markings Are complete with mounting brackets or hardware, when applicable The Contractor shall not substitute extinguisher types, capacities, or manufacturers without prior written approval from the City. Accessories When requested by the City, the Contractor shall provide compatible fire extinguisher accessories, including but not limited to: Mounting brackets Vehicle mounting hardware Fire extinguisher cabinets Cabinet replacement components Identification signs Inspection tags Tamper seals Other related fire extinguisher accessories Product Approval The City reserves the right to reject any product, material, or replacement component that does not comply with the requirements of this solicitation or is determined to be unsuitable for the intended application. The Contractor shall replace any rejected product at no additional cost to the City. Notice Inviting Bids For Fire Extinguisher Inspection, Maintenance, Testing, Repair Services and Parts Notice is hereby given that the City of Pasadena is calling for sealed bids for the Public Works Department, BSFMD and will receive sealed bids prior to 3:00 pm , Thursday, December 10, 2026 and will electronically unseal and make them available online ( https://procurement.opengov.com/portal/pasadena/projects/309516 ) for this solicitation named " Fire Extinguisher Inspection, Maintenance, Testing, Repair Services and Parts " Project ID: 2026-IFB-LM-0555 . Summary The City of Pasadena Department of Public Works, Building Systems and Fleet Management Division (BSFMD) is seeking a qualified vendor to provide comprehensive fire extinguisher inspection, maintenance, testing, certification, repair, recharging, hydrostatic testing, replacement, and related parts and support services for fire extinguishers located throughout City-owned facilities, fleet vehicles, and equipment. Services shall be provided on an as-needed and scheduled basis and performed in accordance with the latest editions of National Fire Protection Association (NFPA) 10, Office of the State Fire Marshal (OSFM) requirements, Occupational Safety and Health Administration (OSHA), California Occupational Safety and Health Administration (Cal/OSHA), manufacturer recommendations, and all applicable federal, state, and local regulations. The resulting contract will ensure fire extinguishers remain properly inspected, maintained, tested, and ready for emergency use while minimizing operational disruptions to City facilities and fleet operations. Delivery Instructions Bids will be received via the City's eProcurement Portal ( https://procurement.opengov.com/portal/pasadena ). A bid received after the time set for the bid opening shall not be considered. Bidders are required to submit (upload) all items listed in the Submittals/Checklist . Bids will be received prior to 3:00 pm on Thursday, December 10, 2026 and will be opened online at that time. Copies of the Specifications and all required forms may be obtained for this solicitation on
Published attachments
- CITY BUILDING LOCATIONS
- CITY BUILDING QUADRANT
- GENERAL INSURANCE REQUIREMENTS WITH PROFESSIONAL LIABILITY
- MASTER LABOR AND MATERIALS CONTRACT (12-18-24)
- REQUIRED FORMS - AAs - SIG-LEGAL-STATUS - DECLARATION OF NONCOLUSION 08022024 v2
- RELEVANT EXPERIENCE FORM
- Fire_Extinguisher_Inspection,_Maintenance,_Testing,_Repair_Services_and_Parts.pdf
Public questions and answers
“The bid requires a copy of the bidder’s CSFM license and DOT cylinder requalification/retester ID. Will the City accept the requalifier ID (RIN) of a listed subcontractor who performs hydrostatic testing on the bidder’s behalf, together with the bidder’s CSFM license?”
Yes. The City allows subcontractors and will accept the DOT Requalifier Identification Number (RIN) of either the contractor or subcontractor performing the hydrostatic testing, provided the applicable requirements are met. However, the awarded contractor shall remain responsible for the performance of all services and compliance with all contract requirements, including work performed by subcontractors.
OpenGov categories
- 42361 · Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers
- 423610 · Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers
- 56199 · All Other Support Services
- 561990 · All Other Support Services
- 81131 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- 811310 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- 92216 · Fire Protection
- 922160 · Fire Protection