Each generator shall receive the listed number of service visits annually unless otherwise specified by the customer. Parts, repairs and / or fluid changes must be done with parts and fluids that meet or exceed the manufacturer’s specifications and requirements. Any substitution of these parts, fluids, or the changing of any factory settings must be approved by the county representative. Any used oil or fluids taken out of the generators must be transported and properly disposed of. Annual Service Cost Hourly Rate for Unscheduled Service Hourly Rate for Emergency Call Outs Material Cost Table Material Cost plus discount Project Details Each generator shall receive the listed number of service visits annually unless otherwise specified by the customer. Parts, repairs and / or fluid changes must be done with parts and fluids that meet or exceed the manufacturer’s specifications and requirements. Any substitution of these parts, fluids, or the changing of any factory settings must be approved by the county representative. Any used oil or fluids taken out of the generators must be transported and properly disposed of. Escambia County is accepting electronic quote submissions. Bidders shall create a FREE account with OpenGov Procurement by signing up at https://procurement.opengov.com/signup . Once you have completed account registration, browse back to this page, click on "Submit Response", and follow the instructions to submit the electronic bid. Selected Vendor Requirements: Scope of Work or Project Details Selected Vendor Requirements: Preventative Maintenance Includes: COOLING SYSTEM Inspect radiator exchanger Check coolant level – Add up to one gallon included in PM. Glycol check of coolant Inspect all hoses and connections Inspect fan drive pulley and fan Inspect fan belts Check jacket water heater Inspect water pump Inspect thermostats FUEL SYSTEM Inspect fuel tank Change fuel/water separator strainers Inspect all fuel lines and connections Inspect governor and controls Change fuel filters (One annually) Check fuel pressure Test fuel in tanks for water AIR INTAKE & EXHAUST SYSTEM Change air filter ( One annually ) Check air filter service indicator Inspect air inlet system Inspect turbocharger Check exhaust manifold Inspect exhaust system ENGINE MONITORS & SAFETY CONTROLS Check all gauges Check all safety controls Check remote enunciators & alarms LUBE OIL SYSTEM Check oil level Change oil filter & date with permanent ink (One annually) Check oil pressure Inspect crankcase breather Check for any leaks Change oil (One annually) STARTING SYSTEM Inspect batteries, terminals & connections Check specific gravity of batteries (results must be turned in) Perform load test on batteries (results must be turned in) Inspect battery charger Inspect starting motor Inspect alternator GENERATOR Inspect bearings Check vibration isolators Inspect control panel Check start controls Check voltmeter Check ammeter Check frequency meter Check circuit breaker TRANSFER SWITCH Inspect all connections (retighten if necessary) Inspect wiring for brittle or burn marks Inspect all switches Perform “drop-dead” test to ensure correct transfer of utility power to generator and then back to unitality power. Load test the site, adjust and calibrate voltages, frequency, and V.S.R.’s. SHELTER Sweep Generator Shelter Area Apply and remove absorbent on any fluids Remove any loose waste products from shelter PROVIDE WRITTEN DOCUMENTATION OF ALL WORK PERFORMED Generator Emergency Service Emergency Service 24/7/365 Critical Response time as needed: (4) hours or less Due to the nature of Public Safety, generators supporting a critical function (tower sites, Mobile Command, etc.) will require immediate service in the event of a generator failure or malfunction. The Contractor must provide 24/7/365 on-call repair services and be on site within two (4) hours of receiving the call. Contractor is expected to keep basic/routine parts on hand for emergency repair services. All parts, repairs and / or fluid changes must be done with parts and fluids that meet or exceeds the manufacturer’s specifications and requirements. Any substitution of these parts, fluids, or the changing of any factory settings must be approved by the county representative. Any used oil or fluids taken out of the generators must be transported and properly disposed of. A repair is defined as a deficiency which is identified during regular preventive maintenance that is not the result of normal wear and tear and is not because of any improper performance by the Contractor or failure to perform preventative maintenance. Contractor should prepare and submit to the county representative a written not-to exceed estimate to perform any major repairs. Repairs shall be made only with the written authorization of the county representative. The county representative may obtain additional repair cost estimates and authorize major repair work to be done by another contractor when it is determined to be in the best interest of the county. 1) Workers Compensation Coverage The Offeror shall purchase and maintain worker’s compensation insurance for all worker’s compensation obligations with Statutory Limits for Part A and with Employer's Liability (Part B) limits of at least $1,000,000.00 each accident/ $1,000,000.00 each employee/ $1,000,000.00 policy limit for disease, or a valid certificate of exemption issued by the state of Florida, or an affidavit in accordance with the provisions of Florida Workers Compensation law. Offeror shall also purchase any other coverages required by law for the benefit of employees. 2) General Liability Coverage Minimum limits of $1,000,000 per occurrence and $2,000,000 annual aggregate for all liability must be provided with excess or umbrella insurance making up the difference, if any, between the policy limits of underlying policies (including employer’s liability required in the worker's compensation coverage section) and the total amount of coverage required. Coverage A shall include Bodily Injury and Property Damage liability for premises, operations, products and completed operations, independent contractors, contractual liability covering this agreement, contract or leasebroad and broad form property damage coverages. Coverage B shall include Personal Injury. Coverage C, Medical Payments, is required. 3) Business Auto Liability Coverage Minimum limit of $1,000,000 per accident or occurrence. Automobile liability coverage is to include Bodily Injury and Property Damage arising out of ownership, maintenance, or use of any auto, including owned, non-owned and hired automobiles and for any employee or subcontractor’s non-ownership use of an auto. Introduction Summary Background Contact Information Timeline Pricing Table Attachments Attachments should include any photos, images, plans of the space you seek a quote for if applicable, or any supporting details prospective vendors may need to know. The Scope of Work should NOT be a separate attachment. Put the Scope of Work in the Project Details section please. Vendor Submissions
Published attachments
Public questions and answers
How many generators are included in this bid? What is the make/model and kW rating of each?
There will be a total of 27 generators, varying in make, model, and capacity. Please refer to the attached document for a complete list of all generator makes, models, and sizes.
OpenGov categories
- 28537 · Generators, Portable, Engine Driven (Including Fog and Mist Types)
- 28539 · Generators, Stationary Type (Not Automotive)
- 94100 · Equipment Maint, Repair, And Related Services For Power Generation And Transmission Equip.