The City of Phoenix invites sealed offers for maintenance, repair, replacement, and support services for low voltage systems . The Effective Date of this Agreement will be upon final signature and recording by the City Clerk’s department. The Commencement Date of this Agreement will be upon a April 1, 2027 or the Effective Date, whichever is later. The term of this Agreement will be for 5 years, beginning on the Commencement Date, with no options to extend. This solicitation is available through the City’s Procurement Portal. For technical support issues related to the City's Procurement Portal, Offeror may use the support bubble on the bottom right, or email procurement-support@opengov.com for any assistance. For other issues related to this solicitation please contact the procurement officer listed under Contact Information. Notwithstanding the foregoing, this Agreement will terminate upon the earliest occurrence: by reaching the end of the term including any extensions exercised, or termination pursuant to the provisions of this Agreement. Scope of Work Introduction The City of Phoenix Aviation Department (Aviation) invites sealed Offers from qualified Offerors to provide maintenance, repair, replacement, and support services for low‑voltage systems for a five‑year contract term commencing on or about April 1, 2027. The awarded Contractor will be responsible for servicing existing low‑voltage systems, including troubleshooting, component replacement, end‑of‑life upgrades, system restoration, and technical support for fire alarm, access control, security, structured cabling, and related control systems. Services include ongoing support to ensure, reliability and compliance across Phoenix Sky Harbor International Airport, Deer Valley Airport, and Goodyear Airport, collectively referred to as “Airports”. The Aviation Department is a 24-hour-a-day, 7-day-a-week, every day of the calendar year operation subject to Federal Aviation Administration (FAA) security mandates. All staff under this Contract must pass a Security Threat Assessment and Criminal Background Check to obtain a security badge and the airfield driving permit endorsement. Aviation Department Representative The Aviation Department Representative (ADR) for this Contract is listed in the table below. The ADR or designee will coordinate all work and be the sole judge concerning acceptability and quality of work. The ADR or designee will be consulted by the Contractor on any concerns and issues arising during the performance of this Contract. Section Name Title Phone Email Energy Systems Al Plant Lead User Technology Specialist (602)273-2059 al.plant@phoenix.gov Definition For the purposes of this Contract, “low‑voltage system support” refers to the maintenance, repair, replacement, and troubleshooting of existing low‑voltage systems operating at 50 Volts of Direct Current (VDC) or less. This includes fire alarms, access control, security and intrusion detection, structured cabling, fiber and copper communication pathways, Closed-Circuit Television (CCTV), audio‑visual controls, and other related monitoring or control systems currently installed at the Airports. Applicable Laws and Standards The Contractor must comply with: Aviation Department guidelines as they pertain to insurance and security. All City, State, and Federal laws and regulations, and accepted industry standards and regulations that govern the work's requirements. Occupational Safety and Health Administration (OSHA) requirements. National Fire Protection Association (NFPA) requirements. Associated building codes and International Building Codes (IBC). International Fire Codes (IFC). Local Authority Having Jurisdiction (AHJ) requirements. National Electrical Code (NEC). Locations This Contract will provide services to City owned airport properties that are managed and maintained by the Aviation Department. These airport properties include, but are not limited to: Phoenix Sky Harbor International Airport (PHX) and surrounding airport properties. Rental Car Center (RCC). Phoenix Deer Valley Airport (DVT). Phoenix Goodyear Airport (GYR). Additions, Deletions, or Replacement The Aviation Department may add or delete services/equipment at any location. If equipment is added, the Contractor must perform repairs or maintenance services as requested. The ADR will advise the Contractor of adding or deleting any equipment location within thirty (30) days' notice. All fees shall be per the existing fees in effect. Contractor Service Requirements Contractor must: Assign a primary Service Representative who will be the City's point of contact at the start of the contract Qualifications - the Service representative must posses at least five (5) years of experience providing low-voltage infrastructure services. Once the service representative is assigned at the contract start date the Contractor must notify the Aviation Department Representative (ADR) or their designee in writing when changing the assigned service representative. Provide all labor, supervision, material(s), equipment, tools, transportation, methods of communication, and any additional Ancillary Services necessary to meet service requirements throughout the term of this Contract. Supply all required devices, panels, cabling, hardware, accessories, UL‑Listed products tested by Underwriters Laboratories (UL Laboratories) and code‑compliant components, manufacturer‑approved equipment compatible with existing systems, and necessary spare parts to support installation, maintenance, and repair activities. Provide a name and contact information for the primary Point of Contact (POC) under the resultant Contract. The POC must be a qualified company representative and available to respond to the city 24 hours per day, seven days a week, every day of the calendar year. A qualified company representative must be knowledgeable about the products and services outlined in this Contract. The POC shall be responsible for coordinating all service activities, updates, scheduling, and communication with City’s ADR or designee. Ancillary Services: Additional service requirements include Cellular and/or radio dialer installation, configuration and testing of low-voltage infrastructure systems including data cabling, access controls, CCTV and audio-visual components. As well as system integration, troubleshooting and upgrades to support evolving technological needs. Preventative maintenance, and technical support to ensure reliable operation and compliance with industry standards. Support, maintain, and repair the full range of covered systems, including fire alarm and life safety systems, access control systems, security and intrusion detection systems, structured cabling, fiber and copper infrastructure, and additional specialty low-voltage systems as required by Aviation. Provide on-call system services for programming, configuration, documentation management, and software/firmware updates for all supported systems, ensuring compatibility with existing platforms and the Contract requirements. Notify ADR or designee when firmware or software reaches end‑of‑support and provide recommended upgrade paths. Deliver non-urgent scheduled services, urgent services with security or access impact, and emergency / life safety issues non-schedule 24/7 service response. See below for a more detailed description: Non-Urgent Scheduled Services : These are standard maintenance or repair needs that do not impact life safety or critical security operations. Routine service ensures consistent upkeep and reliability of existing systems. On-site response within 3 to 5 business days. Examples include but not limited to: Scheduled repairs. Non-critical device replacements. Routine troubleshooting. Updates and adjustments that do not jeopardize safety or security. Urgent Service with Security or Access Impact: These issues affect security integrity or access control but do not pose an immediate life‑safety threat. Urgent issues must be addressed quickly to maintain security compliance and operational continuity. Urgent issues shall be prioritized ahead of routine work unless otherwise directed by ADR. On-site response must be within 24 hours. Examples include but are not limited to: Card readers, door controllers, or electrified hardware failures that restrict required access or compromise security. Intrusion system failures in secured areas. Camera failures in critical security zones. Emergency / Life Safety Issues Non-Scheduled 24/7 Services: These are situations that pose an immediate risk to life safety or could impact critical fire alarm or emergency communication functions. Emergency issues require immediate action to restore safe operation or to stabilize systems until permanent repairs can be made. On-site response must be within 4 hours. Contractor must notify ADR upon arrival and again upon stabilization or resolution of the issue. Examples include but not limited to: Fire alarm system failures or trouble conditions affecting notification or detection. Loss of monitoring of fire alarm panels. System faults that prevent the initiation of emergency sequences (elevator recall, HVAC shutdown, etc.). Provide detailed testing, commissioning, and validation for all repaired or modified systems, including but not limited to: point‑to‑point verification, NFPA‑compliant fire alarm testing, system programming validation, and support for AHJ inspections and acceptance procedures. ADR or designee will issue a required pre‑inspection that must be completed prior to any final testing, commissioning, or AHJ inspections. Maintain and update all documentation including as built drawings, device addressing schedules, labeling, programming backups, and Operations and Maintenance (O&M) manuals. Ensure that all service and installation personnel are certified by recognized national certification organizations or are trained and certified for the systems they work on, as outlined in NFPA 72, Chapter 10 for all fire protection/alarm work being performed. Ensure assigned representatives are qualified specifically part of the Arizona Revised Statutes (A.R.S.) Title 32 – Professions and Occupations, governing certification requirements for alarm agents. The Offeror's assigned service representative may not be changed during the solicitation process, including the time up to contract award. After the contract award, Offeror must notify the Aviation Department Representative (ADR) or their designee in writing when ch Service Exclusions Unless specifically included in this Contract, the following are excluded: Electrical power circuits. Conduit installation (unless directed). Structural modifications. IT network infrastructure not directly related to low-voltage systems. Civil or underground work. Design and construction installation services. Owners Responsibilities The City of Phoenix Aviation Department shall provide: Access to airport owned facilities and secure storage areas. Network access and IP addressing (unless provided by Contractor). Coordination with internal IT and facilities teams. Supported Systems and Equipment The Contractor shall support, maintain, and/or repair the following systems, but not limited to: Fire Alarm & Life Safety System Addressable fire alarm panels and sub‑panels. Initiating devices (smoke, heat, duct detectors, pull stations). Notification appliances (horns, strobes, speakers). Fire alarm monitoring equipment. Auxiliary relays, power supplies, and batteries. Integration with building systems (HVAC shutdown, elevator recall, access control release). Access Control Systems Door controllers, power supplies, and interface modules. Card readers, keypads, biometrics. Electrified hardware (strikes, maglocks, Request-to-Exit device (REX) devices). Door position switches. Credentialing and database configuration. Integration with fire alarm and security systems. Security & Intrusion Detection Systems Intrusion panels, keypads, and sensors. Motion detectors, glass break sensors, door contacts. Panic/duress buttons. Monitoring connections. System programming and user configuration. Structured Cabling & Low-Voltage Infrastructure Cat6/Cat6A cabling. Fiber optic cabling and terminations. Patch panels, racks, cabinets, and labeling. Cable management and pathway installation. Other Low-Voltage Control Systems, as required including by not limited to: Networked building control interfaces. Specialty monitoring systems. Safety, Precautions and Cleanliness Upon repair of any systems or services, the Contractor must: Be solely responsible for means, methods, techniques, procedures, and safety precautions in connection with the performance of these services. Be responsible for the supervision and execution of services by its employees. Have sufficient protective barriers and warning signs available to conduct specified services safely. Supply and wear the required personal protection equipment while performing services under this Contract. Maintain a high standard of cleanliness during and after services. Spillage of products (i.e., grease, sealant), markings (i.e., greasy fingerprints), tools, and miscellaneous materials (i.e., shop towels, used parts, trash) will be removed from the City property daily and upon completion of services. Contractor waste will be removed from City property. The Contractor will leave the work area broom clean. Waste disposal must comply with all local, city, state, and federal laws. All materials, tools, equipment, etc., must be removed or safely stored. The City is not responsible for theft or damage to the Contractor's property. Provide trucks and vehicles licensed for use on public streets and licensed in the State of Arizona. Vehicles must have identification that includes the company's name and/or logo so that it is apparent as to the occupant's nature of business. Identification must appear on both the left and right sides of the vehicle. The Contractor should pursue opportunities to reduce greenhouse gas emissions, such as modes of transportation used to include alternative fuel vehicles. Response Time and Labor Hours Non-Urgent Scheduled Service: Upon initial notification by ADR or designee, the Contractor's initial response (via telephone or email) shall be within 24 hours. On-site response (physical presence) must be within three (3) to five (5) business days. Normal Business Hours : The Aviation Department is a 24-hour, every day of the year operation. This rate is for all work completed except for during Urgent Services and Emergency Response Service. Urgent Service (security or access impact): Card readers, door controllers, or electrified hardware failures that restrict required access or compromise security. Upon initial notification by ADR or designee, the Contractor's initial response must be (via telephone or email) within one (1) hour. On-site response (physical presence) must be within twenty-four (24) hours. Emergency Non-Scheduled Services 24/7 (life safety impact): Fire alarm system failures or trouble conditions affecting notification or detection, loss of monitoring of fire alarm panels, system faults that prevent the initiation of emergency sequences (elevator recall or HVAC shutdown) Upon initial notification by ADR or designee, the Contractor's initial response must be (via telephone or email) within one (1) hour. On-site response (physical presence) must be within four (4) hours. Premium Hours: This rate is for work completed during the Federal holidays observed. This must be approved by the ADR or designee, prior to the services being rendered. Ancillary Additional Services: Installation, configuration and testing of low-voltage infrastructure systems including data cabling, access controls, CCTV and audio-visual components. System integration, troubleshooting and upgrades to support evolving technological needs. Preventative maintenance, and technical support to ensure reliable operation and compliance with industry standards. Billable Labor Hour Requirements: Travel time to and from the job site will not be reimbursable. All mileage and travel costs, including per diem, should be incorporated when providing an hourly rate for labor. All Contractor employees must clock-in upon arrival and clock-out upon departure with the ADR or designee. Billable labor time is calculated in 15-minute increments from “clock-in” to “clock-out” at the City’s facility or with the ADR or designee. Reimbursable labor hours will begin when the Contractor's employee clocks-in and terminates when the Contractor's employee clocks-out. The billable labor hours on the invoice must match the labor hours on the clock-in/clock-out sheet. Training The Contractor must: Provide user training to Aviation staff when system updates or equipment replacements result in changes to system operation, functionality, or user interaction. Proactively notify the ADR or designee when new or modified equipment requires user training and shall coordinate with ADR or designee to schedule and deliver the necessary instruction. Provide training in person or virtually, with the format and length determined by the type of equipment updated or replaced. Conduct on‑site training at City facilities using City equipment. Hourly training rates shall be indicated in the bid price schedule. All manuals, materials, testing, and certificates necessary for required training shall be provided at no additional cost to the City. Training will be conducted during regular business hours as defined in Section 3.12. Specialized Equipment The Contractor is expected to have tools and/or equipment considered standard to the trade available and at no extra cost to the City. The Contractor may be required to utilize special equipment for some projects. The Contractor may be reimbursed at cost for the rental of any specialized equipment (pre-approved by the ADR or designee in writing) required to complete a project. The reimbursement will be for the actual cost to the Contractor. Documentation of the cost must be included with the final invoice, and no markup will be permitted on rental equipment costs. The City will not accept any altered invoice. The ADR or designee will have the final review / approval on all reimbursement invoices submitted by the Contractor. Subcontracting The Contractor must obtain approval from the ADR or designee in writing before any subcontracting work is performed. Aviation reserves the right to check the subcontractor's background and decide to approve or reject the use of the submitted subcontractor(s). The Contractor may be required to subcontract for proprietary items and/or other services. The Contractor must be responsible for all payments to the subcontractor including but not limited to labor, parts, and materials incurred from subcontracting the services to other companies and/or vendors. All subcontracted work will be paid to the Contractor as a pass-through cost with no mark-up . Subcontractor invoice must be included with the Contractor invoice. Subcontractors providing service under this Contract must meet the same service requirements and provide the same quality of service required of the Contractor. No subcontract under this Contract will relieve the primary Contractor of responsibility of service. The Contractor must manage all schedules, quality, performance, and project management for subcontractors. The Contractor will be held solely responsible and accountable for the service and/or repairs for which the Contractor has subcontracted. The Contractor will be responsible for escorting the subcontractor when working in the restricted areas of the airport. The City reserves the right to request that the Contractor remove the subcontractor or any of the subcontractor's staff who are failing to perform under the Contract. The Contractor is responsible for ensuring that any and all
Published attachments
Addenda and notices
Official Notice #1: AVN IFB - 27-0420 Low-Voltage Infrastructure Services - Pre Offer Meeting Documents · 1
Addendum #1 · 1
Public questions and answers
Question regarding IFB 27-0420, Low-Voltage Infrastructure Services. Section 2.9 requires the Offeror to hold an Arizona ROC C-67 or CR-67 license at the time of offer submission. Section 3.15 H states that subcontractors shall hold all valid certifications and licenses required by law to perform the work. Please confirm: must a subcontractor performing low-voltage work under this contract hold an Arizona ROC C-67 or CR-67 license, or is the license requirement limited to the Offeror (prime contractor)? If a subcontractor must hold the license, must that be demonstrated at the time of offer submission, or only before the subcontractor is used (subject to the City's prior written approval under Section 3.15)?
Please see Addendum 1.
Is this solicitation intended to result in a single award to a contractor capable of providing ALL identified low-voltage systems and services, or will the Owner consider qualified Offerors proposing only selected portions of the scope, such as structured cabling, security, or life safety systems?
Please see Addendum 1.
what are the qty do you need? we are material providers.
Please see Addendum 1.
City of Phoenix Aviation Department IFB 27-0420 – Low-Voltage Infrastructure Services ABcom – Formal Requests for Clarification RFI 01 | CRITICAL Reference: IFB §§ 2.2, 2.9, 3.7(K–L), 3.15 Does the C-67 or CR-67 license satisfy all licensing requirements for the full scope, including fire alarm, life-safety, access control, and intrusion systems, or are additional license classifications required for any covered services? RFI 02 | CRITICAL Reference: IFB §§ 2.2, 2.9, 3.7(K–L), 3.15 Can the prime contractor use appropriately licensed and certified subcontractors for fire alarm, security, or other specialized services when those capabilities are not held directly by the prime? Please clarify whether subcontractor qualifications may be used to satisfy the minimum experience requirements. RFI 03 | CRITICAL Reference: IFB §§ 2.2, 2.9, 3.7(K–L), 3.15 What specific technical certifications are required for personnel performing fire alarm testing, repairs, programming, and commissioning? Are NICET certifications required, or will manufacturer-issued certifications or documented NFPA 72-compliant training be accepted? RFI 04 | CRITICAL Reference: IFB §§ 2.2, 2.9, 3.7(K–L), 3.15 What Arizona alarm agent registrations or certifications are required for technicians working on access control, intrusion detection, monitoring, and related security systems? RFI 05 | IMPORTANT Reference: IFB §§ 2.2, 2.9, 3.7(K–L), 3.15 Must the designated service representative personally hold all system qual
Please see Addendum 1.
The solicitation requests service rates based on the urgency and response time requirements of individual service calls. Would the Airport consider an alternative pricing structure that includes a dedicated, full-time, on-site technician under a fixed annual service agreement, with emergency or after-hours services billed separately at an established hourly rate? This approach would provide the Airport with consistent on-site technical support, improved response times, greater familiarity with airport systems and operations, and more predictable annual maintenance costs. If acceptable, would bidders be permitted to submit this dedicated staffing model as an alternative proposal alongside the requested tiered service rates, or must all proposed pricing strictly adhere to the structure outlined in the solicitation?
Please see Addendum 1.
Hello, When will you be sharing the Pre-Conference recording? I would like to share with our Team. Thank you.
Please see Addendum 1.
Can the City provide a list of existing fire alarm manufacturers and systems currently installed at each airport?
Please see Addendum 1.
Can the City provide a list of existing access control, CCTV, intrusion detection, and other low-voltage system manufacturers?
Please see Addendum 1.
Must the prime contractor be qualified to service every system category, or may specialized services be performed by approved subcontractors?
Please see Addendum 1.
Can the City provide historical annual expenditures for low-voltage maintenance and repairs over the previous three years?
Please see Addendum 1.
Approximately how many routine, urgent, and emergency service calls occur annually?
Please see Addendum 1.
Are manufacturer-specific certifications or authorizations required for any existing systems?
Please see Addendum 1.
Is there an established Manufacturer for the cabling across all locations?
Please see Addendum 1.
Can the City clarify whether emergency response times begin upon notification or after airport security clearance and access?
Please see Addendum 1.
Can the City identify any required minimum staffing levels or dedicated personnel?
Please see Addendum 1.
Can the City provide historical annual expenditures for low-voltage maintenance and repairs over the previous three years?
Please see Addendum 1.
Does the City anticipate providing an annual minimum purchase commitment?
Please see Addendum 1.
Will the awarded contractor be required to maintain stock of any frequently used materials of hardware?
Please see Addendum 1.
Will any secure storage be provided to the awarded contractor for equipment, ladders, etc.
Please see Addendum 1.
Are there any fees associated with background clearances, badging, or required training?
Please see Addendum 1.
OpenGov categories
- 28029 · Communications/Telecommunications Cable and Wire
- 28095 · Wire and Cable (Not Otherwise Classified)
- 34016 · Fire Alarm Systems, Power Sirens, and Controls
- 34040 · Fire Suppression Hand Tools: Fire Axe, Fire Rack, Fire Swatter, etc.
- 91132 · C.I.P., Fire Alarm System
- 96218 · Cable Construction, Installation and Maintenance (Fiber Optic, Communication, Computer, etc.)