The City of Phoenix invites sealed offers for modular storage and dosing with ferrous chloride and hydrogen peroxide . The Effective Date of this Agreement will be upon final signature and recording by the City Clerk’s department. The Commencement Date of this Agreement will be upon the approval of the contract by the City Council or the Effective Date, whichever is later. The term of this Agreement will be for 7 years, beginning on the Commencement Date, with no option to extend. This solicitation is available through the City’s Procurement Portal. For technical support issues related to the City's Procurement Portal, Offeror may use the support bubble on the bottom right, or email procurement-support@opengov.com for any assistance. For other issues related to this solicitation please contact the procurement officer listed under Contact Information. Notwithstanding the foregoing, this Agreement will terminate upon the earliest occurrence: by reaching the end of the term including any extensions exercised, or termination pursuant to the provisions of this Agreement. Scope of Work Purpose The City of Phoenix (City) Water Services Department (WSD) is seeking a qualified Contractor to provide a full-service odor control management program (Program) that includes equipment systems and installation, inventory management, storage and delivery logistics, sampling, service monitoring and maintenance, on-going technical and applications support, rate tracking and reporting, performance goal monitoring, and chemical supply of Ferrous Chloride (FeCl₂) and Hydrogen Peroxide (H₂O₂) at designated locations to optimize the wastewater collection system odor control treatment process. The full-service odor and corrosion control services will support specific target locations, as determined by the City. Background WSD uses modular storage and dosing systems to safely store and add (FeCl 2 ) iron salt solution for odor and corrosion control in the sanitary sewer collection system per Federal, State, and Local regulations. These systems are currently located at two (2) locations for FeCl 2 . At one location, the modular dosing system is used to reduce the odors along the 39 th Ave Interceptor. At the second location, the modular dosing system is used with the hydrogen peroxide as part of a comprehensive strategy to abate hydrogen sulfide related odors along the Southern Avenue Interceptor (SAI) sewer. The Contractor shall provide a turnkey operation program designed with the use of hydrogen peroxide as being one of two components to control odors along the SAI in accordance with the Wastewater Collection Division’s odor control goals. Under the Program, iron salts are added in the upper reaches of the collection system as the primary sulfide control agent. Hydrogen peroxide is subsequently applied at designated downstream locations to regenerate spent iron sulfide (FeS), thereby enhancing the overall effectiveness of the sulfide control process. The regeneration step oxidizes the sulfide to elemental sulfur and in the process "frees up" the iron making it re-usable for subsequent downstream sulfide control. For this application, the iron salt (Ferrous/Ferric Chloride) is currently being added upstream by the City of Mesa for odor control along the Baseline Road Interceptor system and will provide the source of spent iron to regenerate for downstream control in the lower Tempe/Phoenix reach of the Southern Avenue Interceptor, (SAI) sewer in accordance with the Sub-Regional Operating Group’s (SROG) partnership. Two (2) separate hydrogen peroxide dosing facilities are currently operating to achieve effective control within the SAI. The Program goals will include minimizing the occurrence/frequency of odor complaints and corrosion in the collection system. In addition, the following specific target levels of hydrogen sulfide treatment will be used to evaluate the effectiveness of the Program provided: Dissolved sulfide daily average at the various City identified target locations less than 1.0 mg/L Vapor hydrogen sulfide daily average at the various City identified target locations main less than 100 ppm. The Contractor shall have a minimum of ten (10) years of continuous experience implementing odor and corrosion control programs that utilize the combined application of ferrous chloride and hydrogen peroxide. As additional sites are identified by the City, the Contractor shall be responsible for providing all services included per this contract. The Contractor’s equipment and system shall include the technologies necessary to meet the odor and corrosion control objective in the designated systems. The Contractor shall also provide all necessary analytical testing and equipment to fulfill the scope of the contract. All aspects of this service contract shall be provided by a single service Contractor who shall have sole responsibility for the product, equipment, and service program. The Contractor may be required to work with City of Tempe and manage utility related matters for sites in that location. Chemical Specifications The ferrous chloride supplied to WSD shall meet the following specifications with no substitutions: The hydrogen peroxide supplied to WSD shall meet the following specifications with no substitutions: Environmental Risk Requirements The Contractor shall remain in compliance with all Department of Transportation (DOT), Environmental Protection Agency (EPA) and Occupational Safety and Health Administration (OSHA) requirements for delivering and handling hazardous materials. The delivery truck will be supplied with appropriate personal protective equipment (PPE) and spill response equipment as required by the laws and regulations. Loctaions Deliveries and services shall occur at the following locations: Ferrous Chloride City of Phoenix Water Services Lift Station 40 5102 E Ray Rad Phoenix, AZ 85044 7000 gallon tank City of Phoenix, Water Services Odor Control Site 72 4653 E Pinnacle Peak RD Glendale, AZ 85310 7500 gallon tank Hydrogen Peroxide City of Phoenix, Water Services Odor Control Site 87 400 W Baseline RD Tempe, AZ 85283 5000 gallon tank City of Phoenix, Water Services Odor Control Site 90 2276 W Southern Ave Phoenix, AZ 85041 7800 gallon tank Storage and Dosing Equipment The Contractor shall provide all necessary dosing and storage equipment to replace existing equipment. (THE SUCCESSFUL PROPOSER MUST PROVIDE ALL NEW STORAGE AND DOSING EQUIPMENT). All storage and dosing equipment must be compatible with the material being stored and pumped. All storage and dosing must meet all City of Phoenix, Maricopa County, State of Arizona, and Federal Regulations. Double contained storage tanks must be provided at all dosing locations from 6500-gallon to 8500-gallon size based on the site, City requirement and constructed of high-density polyethylene for ferrous chloride, please refer to table in Section 3 Scope of Work - paragraph 3.10. Double contained storage tanks must be provided at all dosing locations from 2500-gallon to 8500-gallon size based on the site, City requirement and constructed of high-density polyethylene (HDPE) for hydrogen peroxide, please refer to table in Section 3 Scope of Work - paragraph 3.10. Tertiary containment may be required depending on the site. The City reserves the right to upgrade or increase the storage capacity or the type of control system at any site, at any time throughout the life of the contract. All tanks shall have the internal tank constructed of heavy-duty, high-density polyethylene (HDPE), and the external tank is of linear HDPE, sized to provide 110% containment capacity. The tanks are to be equipped with a reverse level indicator, fill line, and overflow port into the secondary containment, leak detection, ultrasonic level sensor, and proper venting. Tanks specific to hydrogen peroxide service must also have pressure relief devices, passivated wetted components, and properly vented components engineered to prevent high pressurization. A skid-mounted chemical metering pump system shall be provided for each of the (2) ferrous chloride and (2) hydrogen peroxide dosing systems. These systems must be sized to meet the dosing needs of each specific treated section. The hydrogen peroxide skid-mounted metering pump assembly includes a dosing module pre-wired and pre-piped for ease of installation and passivated to the Contractor’s standards prior to shipment to the project site. 304/316 stainless steel tubing is used for all piping and sized per dosing module output requirements. Each pump shall be capable of accepting a remote signal via the Contractor’s dose controller to allow for instantaneous remote adjustments of hydrogen peroxide feed rates, and programming of dose rate profiles (automatic hourly dose rate adjustments) as required. This feature is required to efficiently match chemical feed rates to changing hydrogen sulfide levels and sewage flows over the course of the day. Standard fittings include back-pressure regulator, pressure relief valves, flow meter, and degassing solenoid. Pump capacities shall be sized for the application. The pump skid shall have approximate dimensions of 5 ft. (L) x 3 ft. (W). The dosing module shall be enclosed for weather protection. The ferrous chloride skid-mounted metering pump assembly includes a dosing module pre-wired and pre-piped for ease of installation to the Contractor’s standards prior to shipment to the project site. Schedule 80 PVC piping is used for all chemical feed lines and sized per dosing module output requirements. Each pump shall be capable of accepting a remote signal via the Contractor’s dose controller to allow for instantaneous remote adjustments of ferrous chloride feed rates and programming of dose rate profiles (automatic hourly dose rate adjustments) as required. This feature is required to efficiently match chemical feed rates to changing hydrogen sulfide levels and sewage flows over the course of the day. Standard fittings include a back-pressure regulator, pressure relief valves, flow meter, and degassing solenoid. A tank basket or filter assembly shall be incorporated to prevent debris from entering the system, ensuring reliable operation of the ferrous chloride skid. Pump capacities shall be sized for the application. The pump skid shall have approximate dimensions of 5 ft. (L) x 4 ft. (W). The dosing module shall be enclosed for weather protection. The Contractor shall install piping from the bulk chemical system to injection point plus pack-outs with all installation materials. The Contractor will assist the City with obtaining all City of Phoenix and Maricopa County required construction permits, including but not limited to Phoenix Fire Department Permit Requirements, drawings and schematics necessary for the installation of the storage and delivery system. Additionally, the City reserves the right to add new systems and/or delete systems as the City deems necessary. The Contractor or their Subcontractor must be licensed in the State of Arizona to perform the construction activities required for the proper installation of the specified chemical storage and dosing equipment. All plans and schematics must be stamped by an Engineer registered in the State of Arizona. The Contractor shall provide detailed specifications for all storage tanks, fittings, chemical feed pumps, and additional material/equipment proposed for the City's review and approval. Note that the following civil infrastructure and regulatory and logistical oversights have been placed in effect by the City of Phoenix at the Tempe and Phoenix locations. Adequate access for tank truck deliveries of bulk chemicals. Utilities, including 120 VAC, 40 Amp electrical power, and potable water for safety shower and eyewash. (Phoenix locations only) Site/facility security fencing. (Phoenix locations only) Equipment systems will require a concrete pad or gravel/sand bed for placement of the equipment systems. Any trenching, tapping of lines, drilling through concrete, etc. required to run chemical injection tubing to the application point. Procurement of appropriate HazMat storage permits. Other external items to chemical storage and dosing systems that may be required by Delivery Requirements The Contractor shall ensure that delivery trucks are dedicated to material being delivered or are thoroughly cleaned to maintain National Science Foundation compliance of delivered chemical. All orders shall be delivered Monday through Friday, excluding City holidays, between the hours of 7:00 am and 2:00pm local Arizona time and require prior approval from the City regarding the delivery date. Any deliveries outside of this timeframe will need prior WSD approval. The Contractor’s trucking company shall notify the appropriate yard by phone no less than one (1) hour prior to delivery. The Contractor’s Driver (Driver) shall check in and out with the designated on-site WSD representative. The following shall accompany each delivery and be given to the authorized WSD personnel at each facility receiving the product: Certified weight certificate. A Safety Data Sheet (SDS) shall be provided to the authorized WSD personnel prior to the first delivery for each facility receiving the product. A certificate of accurate analysis (product concentration level) generated by the manufacturer and specific to each delivery. The certificate of analysis shall contain the percentage of soluble iron in the load. The bill of lading, which shall be signed by the Driver in the presence of WSD personnel. All off-loading will be done in the presence of WSD personnel. The Contractor shall be responsible for the prompt clean-up of any chemical spills per their emergency response plan. The Contractor shall ensure that all storage tanks have proper labeling (per Phoenix Fire Code), and are in compliance with local, state and federal requirements. The Contractor shall adhere to the following Department of Transportation (DOT) and City requirements: Tank trailer and appurtenant valves and fittings for delivery and handling of chemicals shall conform to the requirements of the United States DOT and Bureau of Alcohol, Tobacco, Firearms and Explosives. The truck tractor and tank trailer(s) utilized for shipment of chemicals, shall be in good condition, shall be pneumatic tired, and must conform to all Federal, State, County and City regulatory requirements as to licensing, dimensions, weights, safety and all other requirements that may be specified. Emergency Response Information shall be on file with the WSD. This information will be used in the mitigation of an incident involving hazardous materials and, at a minimum, must contain the following information: The basic description and technical name of the hazardous material as required by 49 CFR §§ 172.202 and 172.203(k) as amended; Immediate hazards to health; Risks of fire and health; Immediate precautions to be taken in the event of an accident or incident; Immediate methods for handling fires; Initial methods for handling spills or leaks in the absence of fire; and Preliminary first aid measures. Emergency response information must be printed legibly in English, be available for use away from the package containing the hazardous material and presented on a shipping paper. The Contractor shall follow all safety procedures. If a spill should occur, the Driver is responsible for reporting the spill to WSD staff immediately either onsite or by phone. The spill incident shall be noted on the bill of lading, signed and dated by the Driver. Unloading Requirements The Contractor shall deliver an aqueous solution of ferrous chloride and hydrogen peroxide into the storage tanks. The Contractor shall unload the solution into the tanks by providing labor, material, equipment, and supplies necessary for unloading at the locations specified. WSD personnel will work with the Driver, or other personnel identified by the Contractor, to accept deliveries. Drivers must adhere to the following safety procedures upon arrival at the location: Check safety devices (shower, eyewash, and communications) for proper operation. The Driver shall remain in attendance at all times to ensure that the storage device is filled to the proper level and the product does not overflow. Appropriate PPE must be equipped on delivery trucks and available for use as required by OSHA standards. The Driver shall use appropriate PPE and clear the area of personnel not appropriately protected. Should the Driver exhibit or experience symptoms of illness such as dizziness, cramps, dryness, etc. the Driver should immediately terminate transfer operations and seek first aid. The Contractor shall provide the necessary piping and/or hose to permit transfer of the liquid from the tank trailer to the stationary receiving tanks and shall perform the transfer of the liquid from the tank trailer to the receiving tank. The Driver shall ensure that gaskets and fittings are in good condition and connections are tight. Continuous monitoring by the Driver is required until transfer is complete. The Driver must confirm with WSD personnel that connections are to the proper tank and should ensure that the delivery receipt is read and signed by WSD personnel. Delivery receipt shall be specific, using proper chemical description, not generic terms. Service and Maintenance Services shall be conducted on a weekly basis. Service intervals shall not exceed fifteen (15) calendar days. Scheduled service visits shall include: Vapor and liquid phase (total and dissolved) hydrogen sulfide sampling at multiple locations specified by the City at valid datapoints downstream of chemical sites and areas of concern in support of the Program. pH measurements at the established control point and other specified monitoring locations. Temperature measurements at the established control point and other specified monitoring locations. Scheduled preventative maintenance of equipment. Chemical feed rate adjustment (if necessary). The Contractor shall maintain the following: Chemical storage tanks and containment systems. Chemical feed system, including but not limited to: pumps, pipes/tubing, valves and fittings. Monitor atmospheric testing equipment (OdaLogs) and retrieve monitor data. Internet-Based Monitoring and Reporting The Contractor’s Program shall have an internet-based monitoring and control platform designed to interface with remote telemetry devices. The user interface shall be password protected and accessible on any web enabled device. Access to this web site shall be provided for remote viewing. The system shall be capable of generating email and text alarm notifications of non-compliant conditions at the application and control points with remote telemetry for the following items: Chemical use data Tank levels Trend analysis System alarms Dose curves System configuration Hydrogen sulfide data from monitors The telemetry system shall be capable of controlling the chemical feed pumps remotely. Dosing profiles and chemical feed rates shall be controlled by the Contractor. The Contractor shall submit bi-weekly, monthly, and annual reports in a PDF format to WSD regarding atmospheric and liquid sampling data, chemical use data and trend analysis. System and sampling data will be forwarded to the designated responsible WSD staff via email in a PDF format not to exceed seven (7) days after the site visit. Technicians The Contractor shall have technicians located in the Phoenix metropolitan area. The Contractor’s technicians shall have the capability to provide non-emergency service within 24 hours after notice from the WSD during normal business hours Monday through Friday 7:00am to 2:00pm- excluding weekends and City recognized holidays. The Contractors technicians shall have the capability to respond to emergency situations within two

Published attachments
Addenda and notices
  • Addendum #1 · 1

    This addenda, updates Section 5, Paragraph 5.1

Public questions and answers
  • Can you confirm if this is a 7 year or 10 year term? 10 years is listed on page 5, 7 years listed on page 38, 7 years listed on portal.

    This will be updated in Addenda 1.

  • Is it 900 dry tons of ferrous chloride per year or for the entire term? Is it 380,000 gallons of hydrogen peroxide per year or for the entire term?

    These are yearly estimates.

  • What is the anticipated start date of the contract?

    Based upon The City of Phoenix's City Council approval, the projected award and start date is on or about the first part of 2027

  • What is the delivery size for ferrous chloride and hydrogen peroxide?

    The delivery size is: The peroxide delivery varies from 1500 to 3000 gallons. The ferrous deliveries also vary from 2500 gallons to 4500 gallons or 4 dry tons to 7 dry tons.

  • Can you provide the current supplier and cost for ferrous chloride and hydrogen peroxide?

    This information can be requested via https://www.phoenix.gov/administration/departments/communications/programs/public-records.html

  • May I please get the last bid tab and current supplier/price for Ferrous Chloride?

    This information can be requested via https://www.phoenix.gov/administration/departments/communications/programs/public-records.html

Plain text

OpenGov categories

  • 33536 · Ferrous Sulfate and Chelates of Iron and Zinc
  • 50525 · Chlorine and Peroxygen Bleaches
  • 88560 · Ferrous Sulfate and Ferrous Chloride