State and local · OpenGov
On- Call Plumbing Services
Description
The Bay Area Air District ("Air District") is seeking qualified California-licensed plumbing contractors to provide on-call plumbing maintenance, repair, replacement, installation, and related services at Air District facilities throughout its nine-county jurisdiction. Services will include routine and emergency plumbing work on an as-needed basis. The selected contractor(s) will be required to provide qualified personnel, materials, equipment, and other resources necessary to complete authorized work in accordance with applicable licensing, public works, prevailing wage, and California Department of Industrial Relations ("DIR") requirements. The resulting contract(s) will be for a five (5) year term with a total budget of $50,000. Pricing Table Regular Hours: Monday through Friday, 8:00 a.m. to 5:00 p.m., excluding Air District-observed holidays. After-Hours: Monday through Friday before 8:00 a.m. and after 5:00 p.m. Weekend/Holiday Hours: All hours on Saturdays, Sundays, and Air District-observed holidays. Minimum Billable Hours per Call-Out: Bidder shall identify the minimum number of billable labor hours, if any, applicable to each service call. If no minimum applies, enter “0.” Materials and Parts: Markup shall not exceed ten percent (10%). All proposed rates and charges shall include costs necessary to perform the work in compliance with applicable California public works, prevailing wage, DIR, certified payroll, apprenticeship, licensing, insurance, safety, and other legal requirements. Regular Hours – Journeyman Plumber Regular Hours – Apprentice After-Hours – Journeyman Plumber After-Hours – Apprentice Weekend/Holiday – Journeyman Plumber Weekend/Holiday – Apprentice Emergency Call-Out Fee Travel/Trip Charge Description of Goods and Services The qualified California-licensed plumbing contractor ("Contractor" or "Bidder") shall provide on-call plumbing maintenance, repair, replacement, installation, testing, troubleshooting, and related services at Air District facilities on an as-needed basis. The Contractor shall furnish all labor, supervision, tools, equipment, transportation, materials, supplies, permits, and incidental services necessary to complete authorized plumbing work. Overview Services for this project may include: Work on domestic water; Hot water; Sanitary sewer; Storm drainage; and Items such as: fixtures, toilets, urinals, sinks, faucets, valves, piping, water heaters, backflow prevention devices, regulating valves, pumps, tanks, venting, and related plumbing systems. The Contractor shall coordinate all work with Air District Facilities staff and minimize disruption to building occupants and operations. The Contractor shall provide written estimates when requested and obtain Air District authorization before performing work beyond the approved scope or not-to-exceed amount, except when immediate temporary stabilization is necessary to protect life, health, property, or operations. Service Levels and Response Requirements The Contractor shall provide the following service levels and corresponding response times: Emergency Services: Emergency Services include, but are not limited to: Active water or sewer leak, flooding, sewage backup, loss of essential water service, gas/plumbing condition affecting health or safety, or another condition requiring prompt action to protect persons, property, equipment, or facility operations For Emergency Services, the Contractor shall: Promptly acknowledge the request and make reasonable efforts to arrive onsite with qualified personnel as soon as practicable, with an onsite response time not to exceed four (4) hours, 24 hours/day, 7 days/week, 365 days/year. The four-hour response requirement means that a qualified plumber has arrived onsite and is prepared to assess the condition and begin appropriate work. The Air District recognizes that travel time may vary depending on the service location, traffic, and contractor availability across the nine-county Bay Area; however, the Contractor is expected to make reasonable efforts to respond as quickly as practicable within the four-hour maximum. If a permanent repair cannot be completed during the initial emergency visit, the Contractor shall take reasonable measures to stop, isolate, contain, or otherwise stabilize the condition and protect persons, property, equipment, and Air District operations. The Contractor shall promptly advise the Air District's Facilities team of the condition, temporary measures taken, required parts or materials, and anticipated schedule for permanent repair. Routine Services: Routine Services include, but are not limited to: Standard maintenance, repair, replacement, installation, or other non-emergency plumbing service that can be scheduled during normal business hours. For Routine Services, the Contractor shall: Acknowledge the request and coordinate scheduling within one (1) business day. Onsite service shall generally occur within two (2) business days, or at another date and time agreed to by the Air District's Facilities team. Materials, Parts, and Service Reports Materials and parts shall be new and appropriate for the intended application unless otherwise approved by the Air District. Material and parts markup shall not exceed ten percent (10%). The Contractor shall provide supporting supplier invoices or receipts when requested by the Air District. For each service call, the Contractor shall provide a written service report that includes, at a minimum: Date and location of service; Arrival and departure times; Names and labor classifications of personnel performing the work; Condition or problem identified; Work performed and materials used; Whether the condition was fully repaired or temporarily stabilized; and Recommended follow-up work, if any. Service Area Services may be required at Air District facilities throughout Alameda, Contra Costa, Marin, Napa, San Francisco, San Mateo, Santa Clara, southwestern Solano, and southern Sonoma counties. Contractors shall identify any geographic limitations and must be capable of meeting the applicable response requirements for the service areas they propose to serve. Work Authorization, Task Orders, and Invoicing No work shall begin without Air District authorization except where the Air District's Facilities team expressly directs immediate emergency response. Each task order or other authorization may establish the scope, location, schedule, and not-to-exceed amount. The Contractor shall not exceed an authorized not-to-exceed amount without prior written approval, except for reasonable temporary stabilization specifically authorized by the Air District's Facilities team. Invoices shall identify the applicable task order or authorization and separately show labor hours and classifications, materials, markups, travel or call-out charges, permits, and other approved charges. Supporting documentation shall be provided upon request. Summary The Bay Area Air District ("Air District") is seeking qualified California-licensed plumbing contractors to provide on-call plumbing maintenance, repair, replacement, installation, and related services at Air District facilities throughout its nine-county jurisdiction. Services will include routine and emergency plumbing work on an as-needed basis. The selected contractor(s) will be required to provide qualified personnel, materials, equipment, and other resources necessary to complete authorized work in accordance with applicable licensing, public works, prevailing wage, and California Department of Industrial Relations ("DIR") requirements. The resulting contract(s) will be for a five (5) year term with a total budget of $50,000. To respond to this Invitation for Bids ("IFB"), a respondent should submit its proposal using the Air District's OpenGov Procurement Portal ("Portal"). Proposals must be received before 5:00 pm Pacific Time on Tuesday, November 24, 2026 ("deadline"). Late proposals will not be considered. Bids must address all information requested in this IFB. A bid may add information not requested in this IFB, but the information should be in addition to, not instead of, the requested information and format. Minority business enterprises, women’s business enterprises, veteran’s business enterprises, local businesses, and certified green businesses are encouraged to submit proposals. Any questions regarding this IFB should be submitted through the Question & Answer section of this IFB on the Portal. Background Air District Overview The Air District is the government agency responsible for protecting air quality in the San Francisco Bay Area. The Air District is tasked with regulating stationary sources of air pollution in the nine counties that surround San Francisco Bay: Alameda, Contra Costa, Marin, Napa, San Francisco, San Mateo, Santa Clara, southwestern Solano, and southern Sonoma counties. It is governed by a 24-member Board of Directors composed of locally elected officials from each of the nine counties. The Air District’s mission is to improve air quality to protect public health, reduce historical and current environmental inequities, and mitigate climate change and its impacts. The Air District aims to achieve its mission through many strategic goals, including: reducing and eliminating health problems caused by air pollution, achieving and maintaining air quality standards, leading the Bay Area’s efforts to fight global climate change, creating high-quality regulatory programs, and applying environmental best practices in all operations. To do so, the Air District regulates air pollution emissions from stationary emission sources such as factories, refineries, and power plants, and from smaller facilities like gas stations and dry cleaners. The Air District ensures that such facilities comply with air pollution laws and regulations, provides incentives to replace older, higher-emitting vehicles and equipment with cleaner alternatives, and gives grants and provides outreach to encourage healthy clean air choices by businesses and consumers. The Air District implements these efforts with an equity focus, aiming to reduce air quality disparities and promote environmental justice by targeting local air pollution in overburdened communities. Project The Air District operates administrative, laboratory, warehouse, and field facilities that require reliable plumbing systems. The resulting contract(s) will provide Air District's facilities staff with qualified plumbing resources for routine and emergency work as needs arise. Services may be required at Air District facilities throughout Alameda, Contra Costa, Marin, Napa, San Francisco, San Mateo, Santa Clara, southwestern Solano, and southern Sonoma counties. Bidders shall identify any geographic limitations and must be capable of meeting the applicable response requirements for the service areas they propose to serve. Bidders are responsible for familiarizing themselves with site conditions that may affect the work. Project Sites Services may be required at Air District facilities throughout Alameda, Contra Costa, Marin, Napa, San Francisco, San Mateo, Santa Clara, southwestern Solano, and southern Sonoma counties. Bidders shall identify any geographic limitations and must be capable of meeting the applicable response requirements for the service areas they propose to serve. Bidders are responsible for familiarizing themselves with site conditions that may affect the work. Project Schedule Schedule Anticipated Notice to Proceed: November 30, 2026 Licensing, Registration, and Qualifications Licensing, Registration, and Qualifications The Bidder shall possess a valid California C-36 Plumbing Contractor License for the duration of the project. The Bidder and all subcontractors shall be registered with the California DIR pursuant to Labor Code Section 1725.5. Ensure personnel are properly trained and qualified for assigned work; Use and supervise apprentices in accordance with applicable law; Have experience providing comparable on-call commercial or public-agency plumbing services; and Maintain sufficient staffing and dispatch capability to meet the service levels established in this Scope of Work. Prevailing Wage and Labor Compliance Prevailing Wage and Labor Compliance This project is a public work subject to California prevailing wage requirements pursuant to Labor Code Section 1720 et seq. The Contractor and all subcontractors shall: Pay not less than the applicable prevailing wage rates Submit certified payroll records as required by law Comply with all applicable labor compliance monitoring and enforcement requirements Insurance and Bonding Insurance and Bonding The successful Bidder shall furnish insurance meeting Air District requirements, including but not limited to: Commercial General Liability Automobile Liability Workers’ Compensation Performance and payment bonds may be required prior to execution of the contract. Permits, Safety, and Codes Permits, Safety, and Codes The Contractor shall obtain all permits, approvals, and inspections required for the work and shall comply with all applicable federal, state, and local laws, ordinances, regulations, safety requirements, and applicable plumbing and building codes. The Contractor shall use appropriate personal protective equipment and comply with applicable lockout/tagout, confined space, and other workplace safety requirements. Hazardous, unsafe, or unforeseen conditions shall be immediately reported to Air District Facilities before proceeding with work that may increase risk or cost. Submission Instructions General Bidders must create an account through the Portal described in this IFB to view IFB documents and addenda, and to submit questions and bids documents. All bids must be made in accordance with the conditions of this IFB. Failure to address any of the requirements is grounds for rejection of the bid. All information should be complete, specific, and as concise as possible. Bids should include any additional information that the respondent deems pertinent to the understanding and evaluation of the bid. The Air District may modify the IFB or issue supplementary information or guidelines during the open solicitation period prior to the deadline. Please check the Portal for updates prior to the deadline. All bids shall constitute firm offers valid for ninety (90) days from the deadline. The Air District reserves the right to reject any and all bids. All questions must be in written form and submitted through the Portal before 5:00 pm Pacific Time on Wednesday, November 11, 2026 ("questions deadline"). Bidders will not be able to submit questions after the Questions Deadline occurs. All questions will be answered in writing and posted on the Portal before 5:00 pm Pacific Time on Monday, November 16, 2026 . The cost for developing the bids is the responsibility of the bidder, and shall not be chargeable to the Air District. Submittal of Bids All bids must be submitted in accordance with the specifications set forth in this IFB. Failure to adhere to these specifications may be cause for the rejection of the bids. Deadline – All bids are due before 5:00 pm Pacific Time , Tuesday, November 24, 2026 . Bids will be unsealed electronically at that time. Portal link: https://procurement.opengov.com/portal/baaqmd. Submittal – Bids must be submitted electronically through the Portal. Electronic submissions submitted via the Portal will be acknowledged with a confirmation email receipt. Respondents will also see the status of their bids showing as "Submitted" within OpenGov Procurement upon successfully submitting. Late bids will not be accepted. Any correction or re-submission of bids will not extend the submittal deadline. Modifications – Once submitted, bids, including the composition of the contracting team, may be altered up until the deadline by "unsubmitting" the bids from the Portal and re-submitting the bid with modifications prior to the deadline. After "unsubmitting" a bid, it must be re-submitted before the deadline or it will not be considered. Bids may not be modified after the deadline. Encrypted or password protected files are prohibited. Bidders assume all risks and are solely responsible for ensuring the Air District is able to access, open, and download file(s) attached to their bid. If the Air District is unable to access or open any file(s) associated with the electronic submission, the Air District will consider those file(s) as not submitted. Bidders are cautioned to ensure that the files attached to the bid are complete. Uploading large documents may take significant time, depending on the size of the file(s) and internet connection speed. Bidders should plan sufficient time before the deadline to finalize their submissions and complete the uploading process. Bidders will not be able to submit documents after the deadline. Grounds for Rejection – A bid may be rejected if it arrives after the deadline, is not in the prescribed format, or is not submitted by an individual authorized to represent the firm. Disposition of the Bids– All responses to this IFB become property of the Air District and will be kept confidential until a recommendation for award of a contract has been announced. Thereafter, submittals are subject to public inspection and disclosure under the California Public Records Act. If a respondent believes that any portion of its submittal is exempt from public disclosure, it may mark that portion “confidential.” The Air District will use reasonable means to ensure that such confidential information is safeguarded, but will not be held liable for inadvertent disclosure of the information. Bids marked “confidential” in their entirety will not be honored, and the Air District will not deny public disclosure of any portion of submittals so marked. By submitting a bid with portions marked “confidential,” a respondent represents it has a good faith belief that such portions are exempt from disclosure under the California Public Records Act and agrees to reimburse the Air District for, and to indemnify, defend, and hold harmless the Air District, its officers, employees, and agents, from and against any and all claims, damages, losses, liabilities, suits, judgments, fines, penalties, costs, and expenses, including without limitation, attorneys’ fees, expenses, and court costs of any nature whatsoever, arising from or relating to the Air District’s non-disclosure of any such designated portions of a bid. Interviews The Air District, at its option, may interview bidders. The interviews will be for the purpose of clarifying the bids. Submittal of new bids material at an interview will not be permitted. Interviews may involve a presentation and/or a question-and-answer session. Interview teams should be representative of the project team. Bid Submittal Requirements Bid Submittal Requirements Each bid submitted in response to this IFB shall include, at a minimum: Bidder name, address, California contractor license number, and DIR registration number Lump‑sum or itemized bid price Proposed schedule for completion Identification of subcontractors (if any) At least three (3) references for similar public works projects Bid Evaluation and Criteria Bid Evaluation and Criteria The contract shall be awarded to the lowest responsive and responsible bidder(s) who meets the minimum licensing, registration, and requirements of this IFB, in accordance with applicable law and Air District procurement requirements. The Air District may enter into multiple contracts to ensure geographic area coverage and general service coverage. In case of a discrepancy between the unit prices and item total, the unit price shall govern. In the event of a discrepancy between the item totals and the grand total price the item totals shall prevail. The Air District reserves th
Published attachments
OpenGov categories
- 30180000 · Plumbing fixtures
- 72101510 · Plumbing system maintenance or repair
- 72151100 · Plumbing construction services
- 81141807 · Plumbing or sewer inspection service