State and local · OpenGov
RFQ AE- 2108B DESIGN OF TMT WOOD PELLET RAIL YARD & RTG FACILITY
Description
The JPA is requesting Statements of Qualifications (SOQs) from professional Consultant Firms interested in providing DESIGN SERVICES FOR THE DESIGN OF TMT WOOD PELLET RAIL YARD & RTG FACILITY for the Jacksonville Port Authority to design a new rail yard and rubber-tired gantry (RTG) transfer facility at Talleyrand Marine Terminal. The JPA is specifically seeking a Consultant Firm capable and with experience in providing design services for the maritime industry or ports of similar size. Project Details Important Instructions for Electronic Submittals The Jacksonville Port Authority is accepting Statement of Qualifications. Proposers shall create a FREE account with OpenGov Procurement by signing up at https://procurement.opengov.com/signup . Once you have completed account registration, browse back to this page, click on "Draft Response", and follow the instructions to submit the Statement of Qualifications. Scope of Work or Project Details Please see the Attachments section for specifications and attachments. Insurance Please refer to contract documents. SBE Please refer to contract documents. Introduction The Jacksonville Port Authority (JAXPORT) is a full-service international trade seaport located in the Southeastern United States and is the global gateway to the State of Florida, the third most populous state in the nation. JAXPORT owns, maintains and markets three cargo terminals, two intermodal rail terminals and one passenger cruise terminal along the St. Johns River. JAXPORT and its maritime partners handle a variety of cargoes, including: containerized freight automobiles, recreational boats and construction equipment (roll-on roll-off or Ro/Ro) breakbulk commodities dry and liquid bulks and over-sized and specialty cargoes. JAXPORT’s three marine terminals handled more than 10 million tons of cargo in 2025, including 1.3 million TEUs (containers) – making Jacksonville the largest container handling port in Florida – and 500,000+ vehicles, ensuring JAXPORT’s ranking as one of the top vehicle ports in the U.S. JAXPORT features 19 container cranes, warehousing, Foreign Trade Zone status and intermodal connections enhanced through its two container rail yards. To help speed goods to market, shippers can take advantage of Jacksonville’s location at the crossroads of three major railroads (CSX, Norfolk Southern and Florida East Coast Railway) and three interstate highways (I-95, I-10, and I-75). Cargo activity through the Port of Jacksonville generates 206,000+ jobs in Florida and supports $44 billion in annual economic output for the region and state. Summary The JPA is requesting Statements of Qualifications (SOQs) from professional Consultant Firms interested in providing DESIGN SERVICES FOR THE DESIGN OF TMT WOOD PELLET RAIL YARD & RTG FACILITY for the Jacksonville Port Authority to design a new rail yard and rubber-tired gantry (RTG) transfer facility at Talleyrand Marine Terminal. The JPA is specifically seeking a Consultant Firm capable and with experience in providing design services for the maritime industry or ports of similar size. Timeline Release Project Date: November 5, 2026 Pre-Proposal Meeting (Non-Mandatory): November 12, 2026, 10:00am https://us02web.zoom.us/j/87549028280?pwd=44NunohIVYRnWyhRIph6DFtXwUqYhq.1 Meeting ID: 875 4902 8280 Passcode: 769695 Question Submission Deadline: November 16, 2026, 4:00pm Proposal Submission Deadline: December 1, 2026, 2:00pm https://us02web.zoom.us/j/81843472060?pwd=LUfwCd6AavOZVSkbpw695l9QhffElw.1 Meeting ID: 818 4347 2060 Passcode: 171102 Procurement Contact Elijah Wright Senior Contract Specialist JAXPORT Jacksonville , FL 33206 Email: elijah.wright@jaxport.com Phone: (904) 357-3065 Evaluation Phases Each Proposer is solely responsible for ensuring its Statement of Qualifications (SOQ) adequately responds to the evaluation criteria described below. The Evaluation Committee will rank proposals based on the evaluation factors listed. Final rankings will be determined as described in Section 5.03, including oral presentations by shortlisted Proposers if held. Vendor Questionnaire Attachments
Published attachments
- ATTACHMENT A - Acknowledgement of Addenda and SOQ Signature Page
- ATTACHMENT B - Conflict of Interest Certificate
- ATTACHMENT C - Public Entity Crimes Sworn Statement
- ATTACHMENT D - Certification Regarding Lobbying
- ATTACHMENT E - E-Verify
- ATTACHMENT I - ARTICLE V-7, SEB-FORM 1
- RFQ_AE-2108B
- RFQ AE-2108B Addendum No. 01
Addenda and notices
Addendum #1 · 1
An Addendum which affects the above referenced project, was issued on Wednesday, November 18, 2026 . IT IS MANDATORY THAT THE BIDDER SHALL ACKNOWLEDGE THE INCLUSION OF ALL ADDENDA ON THE BID FORM, FORM BF. ACKNOWLEDGEMENT SHALL BE MADE BY INITIALS AND DATE. FAILURE TO ACKNOWLEDGE ALL ADDENDA SHALL RESULT IN REJECTION OF THE BID. Thank you for your time and efforts on this project. Respectfully, Elijah Wright | Sr. Contract Specialist JAXPORT | Procurement Services Please use the See What Changed link to view all the changes made by this addendum.
Public questions and answers
Will the proposed four-track rail yard and associated turnouts require any modifications to existing railroad signal systems, switch controls, track detection, or grade crossing protection? If so, will railroad signal engineering and design services be included in the consultant's scope of work?
JAXPORT does not anticipate modifications to railroad signal systems, powered switch controls, or track detection. Existing rail within Talleyrand Marine Terminal is terminal trackage switched by WATCO, and the new turnouts are anticipated to be manually operated. The Consultant shall confirm existing conditions during the Siting Study and Preliminary Engineering. If the selected layout requires new or modified grade crossing warning devices, signals, or switch controls, the design of those elements is included in the Consultant’s scope under Section 3.05, and the Consultant’s team should include, or be able to add, appropriate railroad signal design capability.
Will it be acceptable if a reciprocity application to obtain Florida PE license is in process? PE is active and current in another state with reciprocity.
Yes. Each individual proposed in the SOQ who will sign and seal engineering documents, including the required key personnel and the Structural and Electrical leads identified in Section 5.02(A), shall hold a current Professional Engineer license in Florida or in another U.S. state. The SOQ shall include a copy of the individual’s current license and identify the issuing state. An individual not licensed in Florida at the time of submission must obtain a Florida Professional Engineer license from the Florida Board of Professional Engineers before JPA issues a Notice to Proceed.
Confirm "current address" means assigned office address. Section A is ‘Ability of Personnel and Experience” so does location of personnel affect scoring?
Yes. “Current address” in Section 5.02(A) means the address of the office to which the individual is assigned. Personnel location is not scored under Factor A, Ability of Personnel and Experience, which evaluates qualifications and experience. Location is considered only under Factor F, Proximity to Project, which evaluates the location of the Proposer’s office as described in that Factor.
Submittal date of December 1, 2026, is immediately after Thanksgiving, and recent Microsoft outage has delayed preparation time. Can we request extension of RFP due date to Dec 4th?
The SOQ due date remains Tuesday, December 1, 2026, at 2:00 PM (ET).
The last sentence states "All services shall be rendered in individually authorized projects." What does this mean? Is AE-2108B an individually authorized project as a whole, or will tasks be authorized individually?
AE-2108B is a single project. Services under the resulting Agreement will be authorized by JPA through one or more written authorizations (Capital Purchase Orders). JPA anticipates authorizing the services described in Section 3 together, but reserves the right to authorize them in phases. Optional services, including CEI, will be authorized only if requested by JPA.
Does the tenant anticipate using reach stackers, side loaders, or other supplemental container-handling equipment?
Reach stackers and top picks are anticipated as the container handling equipment for the staging yard. Final equipment selection has not been determined and is anticipated to be confirmed prior to fee negotiations. Equipment data will be provided to the selected Consultant.
What RTG manufacturer, model, and bogie configuration does the tenant anticipate using?
Final RTG manufacturer and model selection has not been determined and is anticipated to be confirmed prior to fee negotiations. RTG data, including wheel loads, gauge, and bogie configuration, will be provided to the selected Consultant. Proposers should not assume a specific RTG manufacturer or model in their SOQs.
Will JAXPORT consider alternative documentation demonstrating a Proposer’s financial capacity in lieu of an independently audited financial statement? If so, would documentation such as unaudited financial statements, audited overhead rates, federal tax returns, and/or a letter from a financial institution confirming financial standing be acceptable to satisfy this requirement?
No. JAXPORT will not accept alternative documentation in lieu of an independently audited financial statement. Proposers must submit independently audited financial statements as required in the RFQ.
What container-handling equipment and operating methodology does the tenant anticipate using to manage five-high container stacks? Will operations rely on straddle carriers, reach stackers, or a combination of equipment?
Reach stackers and top picks are anticipated as the container handling equipment for the staging yard. Final equipment selection has not been determined and is anticipated to be confirmed prior to fee negotiations.
Does the 12-point minimum font size requirement also apply to text within graphics, headers/footers, and organizational charts?
The 12-point minimum font size in Section 1.04 applies to all text and tables. Text within graphics, organizational charts, and headers/footers may be smaller, provided it remains clearly legible.
Section 1, Required Documentation, Item (d), requires proof of minimum insurance, including Professional Liability coverage. Please confirm whether Professional Liability insurance provided on a per-claim basis, rather than a per-occurrence basis, is acceptable and satisfies the RFQ requirements.
Professional Liability Insurance on a 'claims-made' basis will not be accepted. Required Limits of Insurance state Professional Liability Insurance on a 'per occurrence' basis.
The solicitation requires submission of the firm’s audited financial statement. Due to the confidential and proprietary nature of this information, may the audited financial statement be submitted as a separate document?
Yes, the audited financial statement can be submitted as a separate document.
Attachments “B,” “C,” “D,” “E,” and “I,” and the insurance certificate are not identified as required documentation under Section 4. Please confirm whether these items should be included in Required Forms and Documentation and, if so, whether they are excluded from the 25-page limit.
The Required Forms and Documentation is excluded from the SOQ page limit. To ensure clarity the Required Documents are uploaded separately under the “Attachments” tab. Please complete the forms and upload the forms under the “Project Documents Tab” Section 4. Vendor Questionnaire.
Would JAXPORT consider, at the time of SOQ submission, a qualified Senior Rail Design Engineer who holds a PE license in a different state and has a reciprocity application in process?
Yes. Each individual proposed in the SOQ who will sign and seal engineering documents, including the required key personnel and the Structural and Electrical leads identified in Section 5.02(A), shall hold a current Professional Engineer license in Florida or in another U.S. state. The SOQ shall include a copy of the individual’s current license and identify the issuing state. An individual not licensed in Florida at the time of submission must obtain a Florida Professional Engineer license from the Florida Board of Professional Engineers before JPA issues a Notice to Proceed.
On the Certificate of Insurance submitted with the RFQ Response, should JAXPORT be named as a certificate holder? If yes, what address should be included?
Yes, JAXPORT should be listed as Certificate Holder. Address: 2831 Talleyrand Ave, Jacksonville, FL, 32206
OpenGov categories
- 90610 · Buildings - Architectural Design
- 90625 · Design Build Services
- 91344 · Construction, Railroad
- 92500 · Engineering Services, Professional
- 92533 · Engineer Services, Professional
- 92537 · Facilities Design Services, Engineering
- 94000 · Equipment Maintenance, Repair, Construction, And Related Services For Railroads
- 94065 · Railroad Construction at Street Intersection (Including Maintenance and Repair)