DEPT OF DEFENSE
- Posted
- Oct 13, 2026
- Due
- Oct 22, 2026, 2:00 PM EDT
- Place of performance
- Place of performance not specified
- NAICS
- 237110
- Set-aside
- Small Business Set Aside - Total
DEPT OF DEFENSE · W076 ENDIST TULSA
This scope of work requires the contractor to locate, inspect, and modify an unmapped 700 to 800 foot concrete-encased four inch cast iron sewer line and its associated distribution box, with mandatory Government presence during all site inspections. Key tasks include installing concrete-encased Schedule 40 PVC double-Y clean-outs every 300 feet, exposing and inspecting the distribution box and its 2009 leach field connections, and extending the box cover using a riser and structural cover rated for three ton vehicle traffic protected by four concrete-encased steel safety-yellow bollards. All physical, material, and dimensional adjustments must be documented as Red Line As-Builts on the reference drawing, and any recommended corrective actions for the lateral lines must be delivered via a detailed findings report with comprehensive labor and material cost estimates.
No public document links were provided with this record.