Solid-Dielectric Medium Voltage Switchgear

Description

The purpose of this Request for Proposals (RFP) is to solicit offers from interested and qualified Vendors for solid-dielectric medium voltage (MV) switchgears as described in the Specifications and Scope of Work in section 4 of the RFP. Equipment shall be suitable for utility, industrial, and power plant applications. Mandatory Items - Switchgears - These items will be evaluated and scored for contract award. Prices below shall include and cover all duties, handling and transportation charges and all charges incidental to the requested work excluding Sales Tax or Use Tax. Price changes in future contract years shall be in accordance with the contract. Switchgear, Submersible, 4-position Switchgear, Submersible, 4-position Switchgear, Padmount with enclosure, 4-position Switchgear, Padmount with enclosure, 4-position Switchgear, Padmount with enclosure, 5-position Switchgear, Padmount with enclosure, 5-position Switchgear, Padmount with enclosure, 6-position Switchgear, Padmount with enclosure, 6-position Switchgear, Vault-mount, 4-position Switchgear, Vault-mount, 4-position Switchgear, Vault-mount, 5-position Switchgear, Vault-mount, 5-position Switchgear, Vault-mount, 6-position Switchgear, Vault-mount, 6-position Mandatory Items - Miscellaneous - These items will not be evaluated for contract award but will be included in the contract. Prices below shall include and cover all duties, handling and transportation charges and all charges incidental to the requested work excluding Sales Tax or Use Tax. Price changes in future contract years shall be in accordance with the contract. Revenue Grade Current Transformers Voltage Measuring Devices for Metering Purposes Mandatory Services - On-Site Training - These items will not be evaluated for contract award but will be included in the contract. Prices below shall include and cover all duties, handling and transportation charges and all charges incidental to the requested work excluding Sales Tax or Use Tax. Price changes in future contract years shall be in accordance with the contract. On-Site Training for up to 20 People - Skagit - lump sum including all travel and incidentals On-Site Training for up to 20 People - Boundary - lump sum including all travel and incidentals On-Site Training for up to 20 People - Cedar Falls - lump sum including all travel and incidentals SPECIFICATIONS AND SCOPE OF WORK Solid-Dielectric Medium Voltage Switchgear PART 1 - GENERAL 1.1 General Information For the purposes of this specification, the term Owner shall refer to Seattle City Light (SCL). The City Engineer shall be the party designated by the Owner. The Owner is requesting pricing options for switchgear rated for 15kV and 27kV. The switchgear shall be rated for 15 kV or 27kV respectively, 60 Hz operation and designed in accordance with applicable IEEE, ANSI, and NEMA standards. Equipment shall be suitable for utility, industrial, and power plant applications. The switchgear shall support at least four (4) positions with option for up to six (6) positions, or as required by the Engineer. Each position shall correspond directly to the designations defined in section 1.4(B) Bushing/Way Designations. The switchgear shall meet requirements outlined in the Federal Buy America Act. Pub. L. No. 117-58, §§ 70901-52. 1.2 References The medium voltage switchgear and all components shall be designed, manufactured, and tested in accordance with the latest applicable standards as follows: IEEE C37.60 IEEE C37.74 All Padmount equipment must meet or exceed IEEE C57.12.28 (carbon steel) or IEEE C57.12.29 (409 heat resistant stainless steel) standard for pad-mounted enclosures integrity. If the enclosure is manufactured from 304 corrosion resistant stainless steel the enclosure must meet the applicable and relevant portions of the standards. IEEE 386 Manufacturer of the switchgear must be ISO 9001 certified. 1.3 Electrical Ratings Maximum Voltage: 15 kV rms or 27kV rms BIL: ≥95 kV crest Continuous Current: 600 A Symmetrical Interrupting Current: ≥10 kA rms Asymmetrical Interrupting Current: Per IEEE/ANSI Peak Current: Per IEEE/ANSI Load Capability: Capable of supplying both single-phase and three-phase loads. 1.4 Nameplates User identification, manufacture, and ratings information shall be attached to the switchgear per IEEE C37.71-2001. Bushing/Way Designations Switch position indicators with a numerical designation (e.g. Way 1 through Way 4) and by phase identification (A, B, C) shall be provided for users. For example: 1A, 1B, 1C. 1.5 Submittals – for Review/Approval upon receipt of order The following shall be submitted to the Engineer within 45 days after receipt of order: Master drawing index Front view elevation Floor plan Top view Single line Nameplate schedule Component list Assembly ratings including: Short-circuit rating Voltage Continuous current Basic Impulse Level (BIL) 9.Major component ratings including: Voltage Continuous current Interrupting ratings 10.Seismic Requirements: Switchgear must be designed to meet IEEE 693, Annex M – Metalclad Switchgear. Use a high qualification level for locations within or west of the Cascade Mountain range. Use a moderate qualification level for locations east of the Cascade Mountain range. When a seismic outline drawing is not required by IEEE 693, submit a drawing that includes information needed for anchorage design, but not limited to: Total equipment weight. Center of gravity (CG) coordinates in X, Y, and Z directions. Locations and spacing for anchorage. 11.Seismic Reports: If applicable or available, provide any: Certification reports Seismic analysis-qualification reports Qualification testing 12. Instruction book 1.6 Submittals – for Construction The following information shall be submitted within 7 days of shipment of equipment from factory: Final as-built drawings and information for items listed in section 1.5A. Submittals and shall incorporate all changes made during the manufacturing process. Wiring diagrams Production Test Reports Installation information including equipment anchorage provisions. 1.7 Documentation One instruction book shall be securely attached to each switchgear assembly at the time of delivery, enclosed in an ultraviolet light-resistant envelope. Provision shall be made for the Owner to obtain .dwg (AutoCAD) and .pdf files of all relevant, switch-specific documentation, including but not limited to: Installation instructions Instruction book Outline drawings Wiring and schematic diagrams Build America, Buy America compliance certification 1.8 Options Submit pricing for the following required options for each the 15kV and 27kV switchgears: Submersible, 4-possition Padmount (with enclosure), 4-position Padmount (with enclosure), 5-position Padmount (with enclosure), 6-position Vault-mount, 4-position Vault-mount, 5-position Vault-mount, 6-position Voltage measuring devices for metering purposes On-site training for up to 20 people at each specified location Additional warranty options beyond the requirement Revenue grade current transformers (CTs) Submit pricing for any additional, non-required options including, but not limited to, additional positions for the submersible version. Submersible, 5-position Submersible, 6-position PART 2 PRODUCT – MEDIUM VOLTAGE SWITCHGEAR 2.1 Terminations and Bushings Main Feeders: Provide 600A dead-break bushings, suitable for 15kV-class or 27kV-class separable connectors, fully shielded, insulated, and submersible-rated. Taps and Sectionalizing Ways: Unless otherwise noted by the Engineer, provide 200A load-break bushings, suitable for 15kV-class or 27kV-class separable connectors, fully shielded, insulated, and submersible-rated. Cable parking stands shall be provided on equipment surface adjacent to terminations. Included in parking stands provisions for cable grounding and bleeding. Grounding shall comply with WAC 296-45-345. 2.2 Switchgear Construction Dead-front, sealed design to prevent exposure to live parts. Utilize solid-dielectric insulation technologies that require no maintenance. The design shall not rely on epoxy paint to maintain its dead-front rating, nor shall glue be used to bond rubber insulation components. The visible open shall be fully insulated and shall contain no fluid for dielectric purposes. Vacuum fault interrupter (VFI) mechanisms and all bus conductors shall be fully se PURPOSE AND BACKGROUND Purpose and Background The purpose of this Request for Proposals (RFP) is to solicit offers from interested and qualified Vendors for solid-dielectric medium voltage (MV) switchgears as described in the Specifications and Scope of Work in section 4 of the RFP. Equipment shall be suitable for utility, industrial, and power plant applications. Background : Seattle City Light (hereinafter “City Light” or “SCL”) requires MV switchgear for electrical distribution upgrades at its generation facilities including the Cedar Falls, Skagit and Boundary Hydroelectric Projects. The switchgear must be outdoor rated and fit into existing, historic infrastructure with limited space. The switchgear must also be flexible for multiple vault applications. A true visible break is required to meet safety procedures. Boundary Powerhouse is located on the Pend Oreille River in Pend Oreille County, State of Washington, approximately 120 miles North of Spokane International Airport. The Powerhouse is located at latitude 48.989 and longitude -117.353 which is 9 miles due north of Metaline Falls, WA. It is accessible by heading North off of Washington State Hwy 31 on Boundary Road and veering right at the fork in the road. City Light’s Skagit Hydroelectric project, which includes Ross Dam, is on the Skagit River in Whatcom County, approximately 130 miles northeast of Seattle. The site is located in the North Cascades Recreational Area, part of the National Park System. The Cedar Falls Powerhouse is located approximately 38 miles east of Seattle on the Cedar River, 8 miles south of North Bend, Washington, in King County. Single Award The City intends to award one contract and does not anticipate multiple awards. Regardless, the City reserves the right to make multiple or partial awards. SOLICITATION OBJECTIVES The City expects to achieve the following outcomes through this solicitation: Purchase new MV Switchgears that meet or exceed the requirements of the specification. Select a vendor that demonstrates and shows an ability to produce a well-designed, high quality product. Obtain the best value for Seattle City Light MINIMUM QUALIFICATIONS The following are minimum qualifications that the Vendor must meet to submit a proposal. Proposals that are not clearly responsive to these minimum qualifications will be rejected by the City without further consideration. 1. The manufacturer of the equipment specified herein must be ISO 9001 certified. 2. The manufacturer of this equipment must have produced similar electrical equipment for a minimum of five (5) years. If the Proposer is an authorized distributor, they must have represented the manufacturer for a minimum of five (5) years, and the represented manufacturer must have produced similar electrical equipment for a minimum of five (5) years. A list of installations with similar equipment must be provided demonstrating compliance with this requirement. 3. The Proposer, if other than the manufacturer, shall provide a current, dated, and signed authorization letter from the manufacturer confirming that the Vendor is an authorized distributor, dealer or service representative and may sell the manufacturer's products listed in your proposal response. SCHEDULE, ORDER, DELIVERY Order Desk The vendor shall provide a telephone service or “order desk” to receive calls from City departments for advice or assistance, recommendations on products, parts, and repairs, and for receiving and processing of phone orders. The Order Desk shall be available from 7AM - 5PM PT all business days except City holidays. If your standard operating hours are otherwise, notify the RFP Coordinator (Buyer). Depending on the operating needs of the Department, hours that are similar to, but not exactly the same as the 7AM - 5PM PT schedule may be accepted by the City as compliance to this requirement. Minimum Order Quantities There will be no minimum order quantities for any resultant contract. ENVIRONMENTAL SPECIFICATIONS Environmental Standards Unless notified otherwise by the Vendor, products offered will be considered complaint to USEPA Standards published by the USEPA, unless specified otherwise. See USEPA Standards at: https://www.epa.gov/smm/comprehensive-procurement-guideline-cpg-program. PBT Free Specification - Persistent Bioaccumulative Toxic (PBT) Chemicals – Mercury, Dioxin, PCB. PBDE, Lead, PVC and other The City of Seattle adopted Resolution #30487 in 2002. This Resolution requires that Purchasing and Contracting differentiate products that contain PBT chemicals and those that release PBT chemicals during production or disposal, from those products that do not, and requires Purchasing and Contracting reduce acquisition of products that contain or release PBT chemicals. PBT chemicals are defined as mercury, dioxin, PCB, PBDE (polybrominated diphenyl ethers, i.e. flame retardants), or others as identified on the State of Washington, Department of Ecology PBT priority list (for the complete list, see https://apps.leg.wa.gov/wac/default.aspx?cite=173-333-310 . Unless specifically allowed within this solicitation, all equipment, supplies and other products submitted for Bid/response are to be free of Persistent Bioaccumulative Toxic chemicals including mercury, dioxin, PCB and others as listed in the DOE PBT priority list. If an interested Vendor has a product that contains or releases any PBT materials as defined above, Vendor may notify the City RFP Coordinator by the date specified on the schedule (see Page 1). Should the City determine that the product being acquired by the City does not have a reasonable or economically feasible substitute, the City may amend this PBT-Free requirement to allow for -- or provide a maximum of 10% preference for -- products that include or release the least amount of such PBT chemical as practical. The City may reject responses with PBT content or release, if the responses is not in accordance with this PBT-Free specification or has not amended the specification otherwise. Additional information about such products is available at http://www.ecy.wa.gov/toxhaz.html General and Environmental Indemnification The Contractor shall take all necessary precautions for prevention of accidents, injuries and property damage. The Contractor shall indemnify, release, defend and hold the City and its officers, employees, and agents harmless from and against any and all (1) losses, claims, demands, actions, causes of action, damages, liabilities, judgments and expenses (including reasonable attorneys’ fees and expenses and consulting fees and expenses) and (2) all other losses, claims, demands, actions, causes of action, damages, liabilities, judgments and expenses (including reasonable attorneys’ fees and expenses and consulting fees and expenses) relating to any hazardous, dangerous or toxic material, waste, or substance, or other pollutant or contaminant, or to compliance with any Environmental or Safety Law; arising out of or resulting from: the Contractor’s performance or lack of performance under this Contract, the violation of law or breach of this Contract by the Contractor or any of its employees, agents, or contractors, or the release of any hazardous, dangerous or toxic material, waste, or substance, or other pollutant or contaminant resulting from Contractor’s performance or lack of performance under this Contract or from the violation of law by, breach of this Contract by, or act or omission of the Contractor or any of its employees, agents or subcontractors under this Contract. When the Contractor learns of a claim, or of circumstances reasonably likely to give rise to a claim, against the Contractor or the City, the Contractor shall immediately notify the City. In the event that any suit or claim based upon any such loss, claim, action, damage, expense, or liability is brought against the City, the Contractor, upon notice of the commencement thereof, shall defend the same at its sole cost and expense, except that the City may, at its option and the City’s cost, participate in the defense with counsel of its choosing. If any final court judgment, alternative dispute resolution award or settlement be adverse to the City based on the City’s sole negligence, the Contractor shall not be obligated to pay the judgment, award or settlement. In such case where the Contractor is not obligated to pay, if the City required the Contractor to undertake the City’s defense, the City shall reimburse to the Contractor the amount of any reasonable attorney fees, litigation expenses and costs incurred by the Contractor in defending the City. If both (1) a court of competent jurisdiction issues a final determination that RCW 4.24.115 governs the liability and no appeal of such determination is pending and (2) the liability was caused by or resulted from the concurrent negligence of (a) the Contractor or its officer, agent or employee and (b) the City or its officer, agent or employee, then these indemnity provisions shall be valid and enforceable only to the extent of the Contractor’s negligence. The Contractor shall pay every judgment, alternative dispute resolution award, settlement, and other liability for which the Contractor is responsible when payment is due. If the Contractor fails to do so, and the City pays the liability, the Contractor shall pay the City interest at the statutory rate for judgments, accruing from the date the City pays the liability. The provisions of this section shall survive any termination or expiration of this Contract. In the event that this section conflicts with any other provision of the Contract, this section shall control. The Contractor expressly waives, with respect to the City only, its immunity under RCW Title 51, Industrial Insurance. LICENSING AND BUSINESS TAX REQUIREMENTS The Vendor must meet all licensing requirements that apply to their business immediately after contract award or the City may reject the Vendor before contract execution. Companies must license, report and pay revenue taxes for the Washington State business License (UBI#) and Seattle Business License, if it is required to hold such a license by the laws of those jurisdictions. The Vendor should carefully consider those costs prior to submitting an offer, as the City will not separately pay or reimburse licensing costs. Seattle Business Licensing and associated taxes If you have a “physical nexus” in the city, you must obtain a Seattle Business license and pay all taxes due before the Contract can be signed. A “physical nexus” means you have physical presence, such as: a building/facility located in Seattle, you make sales trips into Seattle, your own company drives into Seattle for product deliveries, and/or you conduct service work in Seattle (repair, installation, service, maintenance work, on-site consulting, etc). We provide a Vendor Questionnaire Form in our submittal package items later in this RFP, and it will ask you to specify if you have “physical nexus”. All costs for any licenses, permits and Seattle Business License taxes owed shall be borne by the Vendor and not charged separately to the City. The apparent successful Vendor must immediately obtain the license and ensure all City taxes are current, unless exempted by City Code due to reasons such as no physical nexus. Failure to do so will result in rejection of the bid/proposal. Self-Filing - You can pay your l

Plain text