State and local · OpenGov
THE FURNISHING, DELIVERY AND INSTALLATION OF WAYFINDING SIGNS
Description
It is the intention of these specifications to provide to prospective bidders the requirements for the Furnishing, Delivery and Installation of Wayfinding Signs for Nexus and Middlesex College, as required by the County of Middlesex. DETAIL SPECIFICATIONS INTENT It is the intention of these specifications to provide to prospective bidders the requirements for the Furnishing, Delivery and Installation of Wayfinding Signs for Nexus and Middlesex College, as required by the County of Middlesex. The County has contracted with Nicholson Associates for the design of this project. "Owner" herein refers to The County of Middlesex. CONTRACT PERIOD The contract shall commence the next business day following the Date of Award and continue for a period of twelve (12) consecutive months. Any services ordered or made within thirty (30) days after the contract expires shall be under the same terms and conditions specified in the bid and contract prices submitted by the vendor, unless said vendor indicates, in writing, thirty (30) days prior to contract expiration, that it will not be bound by said terms, conditions and contract prices. METHOD OF AWARD The contract shall be awarded based on the Lowest Total Combined Lump Sum Amount as submitted on the Bid Sheet. The unit price shall encompass the fabrication, delivery and installation. No additional cost shall be added or accepted. The unit prices shall be held for one year following substantial project completion. The County may add or subtract signs from the project. PROPRIETARY INFORMATION All ideas, designs, and configurations represented by these drawings were created for the one use at the NEXUS Wayfinding and Signage project. None of the ideas, designs, or configurations shall be used for any other purpose, nor may the materials or ideas contained therein be disclosed to any other individual, firm, or corporation without written permission from MIDDLESEX COUNTY. All original materials, including artwork and reproducible drawings shall be returned to MIDDLESEX COUNTY upon completion of the project. DESIGN INTENT DRAWINGS The Design Intent drawings are for the sole purpose of conveying design intent and are not intended for construction purposes. Construction drawings/shop drawings are the responsibility of the winning bidder/contract holder. The awarded bidder shall submit stamped engineering drawings for signs SID's 1, 2 & 3. Representatives designated by the Owner shall review all shop drawings for conformance with the design intent of these drawings and will not be responsible or liable for any results of construction from working drawings, material selection, shop drawings, or any other agreements. These drawings are not to be used as production artwork or patterns unless instructed to do so. Design Intent Drawings can be found under Attachment C. The message scheduled for NEXUS and Middlesex College can be found under Attachment E and F Final You Are Here (YAH) map artwork will be provided for each YAH Orientation sign included in the project. The artwork will be provided in pdf format. The fabricator is not expected to make alterations to the artwork. QUALITY ASSURANCE Contractor Qualifications: The contractor shall be responsible for the quality and delivery of all materials and workmanship required for the execution of this contract. It is expected that the fabricator have in-house knowledge, diverse shop and field experience, coordinating ability, skilled craftsmen, and a physical plant necessary to produce quality products equivalent to, or better than, similar type products in use in the industry. These general requirements apply equally to the contractor and to their subcontractors. Contractors shall be responsible for providing all subcontractors with complete and up-to-date drawings, specifications, and other information issued by the project manager. Contractor to submit qualifying data to the Owner for approval. The Fabricator or Installer shall notify Nicolson Associates of any discrepancies in the documents immediately and shall not proceed or allow fabricators to work in those areas until said discrepancies are resolved. When changes are required, for any reason, notify the Owner & Nicolson Associates before performing any work. Changes which alter the contract documents must have the approval of Nicolson Associates before commencement of such work. Changes which modify the contract amount must have the approval of Nicolson Associates before commencement of such work. The Contractor may make recommendations and/or changes to the details as shown on the drawings, if such recommendations are approved in writing by the Owner prior to shop drawings or fabrication of prototypes or samples The Contractor shall base their proposal on the performance of all services, including all labor, materials, and equipment for the complete fabrication and installation of the product at the agreed upon schedule. For the purpose of bidding process, proprietary names identifying items of work are used solely to describe the standard of the product or the color of the finish, unless the items of work are explicitly noted as not having an equal. Fabricator shall secure approval of any substitutions from Nicolson Associates. Any items approved for substitution shall be submitted to Nicolson Associates for final approval. All fabricated surfaces are to be free of defects, including but not limited to ripples, weld marks, “oil canning,” etc. Seams, where visible, are to be straight and true. All acrylic sheeting used is to be of sufficient thickness and weight to prevent concave surfaces. All metal surfaces are to be prepared in a manner for permanent paint and film adhesion and prevention of corrosion. All metals are to be painted with automotive polyurethane paint, or powder coated (unless otherwise specified). No sheet metal construction will be accepted, except as noted. All welds shall be ground smooth and blended into adjacent surfaces. All fabricated surfaces shall be free from visible warps and finish blemishes. No “oil canning” will be accepted. No visible seams or fasteners except noted. All surfaces shall be free of weld and cut marks. Mock-ups to be provided for all welded conditions. Where dissimilar metals are indicated, isolate and/or gasket as required. All edges on exhibits should be radiused and softened, 1/8-inch minimum. Sharp edges are unacceptable as they can cause injury. Contractor must review metal parts for sharpness. All interior finish and trim materials are to meet Class C flame spread ratings of 76 to 200, or per applicable code. All acrylic to have a UL flame class of 92HB. All MDF to be MDF IBC 803, Class A fire retardant material. Flame index 0-25 and smoke-developed index 0-450 Any imagery, video content, written text, or brand trademarks (where applicable) should be legally cleared by the issuing body and verified by the client to be used for perpetuity. DESIGN CRITERIA Structural Design: Details on drawings indicate a design approach for sign and exhibit structures but do not necessarily include all fabrication details required for the complete structural integrity of the signs and exhibits, including consideration for static, dynamic and erection loads during handling, erecting and service at the installed locations, nor do they necessarily consider the preferred shop practices of the individual general sign and exhibit contractors. Therefore it shall be the responsibility of the Contractor to perform the complete structural design of the signs and to incorporate all the reasonable safety factors necessary to protect the Owner and sign and exhibit fabricator against public liability. Designs which survive rational engineering analysis and conform to all applicable national and local codes will be acceptable. Only pre-approved anchors and fasteners shall be used in conformance with structural design criteria and should match surrounding or adjacent surface whenever possible. Engineer to resist wind and seismic loads in accordance to all local, state and federal building codes. When lifting eyes are required because of size or weight of the sign, provide as an integral part of the internal structural design. Lifting eyes shall be as inconspicuous as possible in the finished work and removed if at all possible. Submit calculations stamped and sealed by a licensed, registered professional engineer licensed in state of work. The awarded bidder shall submit stamped engineering drawings for signs SID's 1, 2 & 3. Electrical Design: It shall be the responsibility of the Contractor to perform the complete electrical design for illuminated signs and to coordinate power, location requirements, blocking and structure with the General Contractor. Contractor shall provide all electrical hardware and components as required. Field determine routing of connectors, wiring, etc. Establish location of raceways, transformers for concealment as well as access. Provide access to all connections and components for general maintenance. All removable panels, hand-holes, etc. shall be weatherproof and flush with adjacent surfaces. Provide lighting medium indicated on the drawings. Provide lighting grounding for all ground-mounted signs. Submit calculations signed and sealed by a licensed, professional engineer in the state of work. All components must be fabricated in accordance with local and national electrical codes. Sign and exhibit fabricator shall coordinate power requirements, electrical connections and blocking with General Contractor. All internally illuminated signage shall be UL listed. Contractor to provide sign templates with electrical penetrations for all signage for coordination with the General Contractor. All final connections to be made by a licensed electrician, whether the Electrical Contractor or subcontracted by exhibit fabricator. Dimensions Do not scale the drawings. All sign copy and graphics should be considered to be representative and are subject to change. Refer to content schedule for final copy on all signs. Refer to location plans for final locations for all signage. Written dimensions on the drawings shall take precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions shown by these drawings and shall be responsible for confirming all field dimensions and conditions prior to beginning fabrication. Contractor will determine the copy, quantities and references in accordance with location plans. All messages are to be approved by the Owner. Locations of signs and exhibits shown on the plans are for general information. The Contractor shall confirm each sign location with the Owner and Nicolson Associates prior to installation. All dimensions are to the exterior face of the finished material unless otherwise noted. All elevations are noted from finish floor elevations. All dimensions of existing work and all dimensions required for work that is connected with work in place shall be verified by the Fabricator and Installer. In addition, the Fabricator shall verify all finishes and notify Nicolson Associates of any discrepancies before performing any work. Execution: Contractor shall notify the Nicolson Associates of any discrepancies in the drawings or graphics schedule, in field dimensions or conditions, and/or changes required in construction details. All discrepancies shall be brought to the attention of the Owner. CONTRACTOR RESPONSIBILITY Prior to commencing any work, the Fabricator or Installer who is awarded all or part of fabrication and/or installation shall review with the Owner, Architect, and Nicolson Associates the phasing of their work and secure approval from all parties. Submit to the Architect and Nicolson Associates a master schedule of the awarded work one (1) week after the contract signing. Contractor shall install design as shown on approved contracting documents. Documents should represent signs and exhibits in accordance with the local code. If they are not, notice shall be brought to the sign designer and Owner's attention by letter, email, and in the shop drawings prepared by the sign contractor. Prepare shop drawings, product data and samples prior to submittal. Verify field measurements, field construction criteria, catalog numbers and similar data. Contractor’s responsibility for deviations in submittals from requirements of these design intent drawings is not relieved by the Owner's review of submittals unless the Owner gives written acceptance of specific deviations. A deviation shall be construed to mean a minor change to the sequence indicated on the drawings or specifications. A deviation is not intended to allow substitutions or product options. In addition to notifying the Owner in writing of deviations, such deviations shall be circled on the shop drawings. Work shall not begin until the corresponding submittals have been reviewed and approved by Owner. Sign and exhibit contractor shall provide engineering services and a dedicated project manager. Sign and exhibit designer shall be responsible for ADA compliance of all signage. Compliance with ANSI A117.1 required. All installations shall be coordinated with the Building Contractor, Architect and Owner. All finishes to be protected. Contractor shall be responsible for any damages to finishes during installation. Contractor should clean all signs and exhibits prior to installation of all items. ARTWORK Artwork for all signs and exhibits contained within this document are Design Intent drawings only. Bidders will be provided with a copy of artwork only as it pertains to design aesthetics. Final images and copy to be provided by the Owner and the Bidder is responsible for all final artwork. The artwork provided in this document will not be color-separated nor will it provide for trapping, overprinting or other requirements specific to the production method. All enlarging and reducing is the responsibility of the Contractor. Do not use paper prints as originals for templates. Contractor will be responsible for converting the provided artwork to whatever medium or format required. All copy must be verified with Owner prior to fabrication. Final artwork will be provided to the Owner in Adobe InDesign, Adobe Illustrator, and Adobe PDF formats as applicable. All digital print artwork to have at least 1” overlap at seams. Labels There shall be no visible labels on the completed signs and exhibits unless required by law. Inspection The Contractor shall examine the substrates and conditions on which the signs and exhibits are to be installed and notify the Owner and their designated representative(s) in writing of conditions that would impede the proper and timely completion of the work. Do not proceed with the work until all unsatisfactory conditions have been remedied. SUBMITTALS Shop Drawings The Contractor shall submit an electronic set (PDF) to the Owner/Architect prior to production. These drawings are to be submitted one month prior to the date they need to be returned to the Contractor. The drawings are to show all materials, thicknesses, finishes, construction details, installation details, structure, artwork and illumination as well as the location of all seams, finished and unfinished. Drawings shall indicate locations of all transformers or other components which require access by service personnel, clearly describing methods of access to each point. All dimensions are to be in United States feet and inches. Review of shop drawings will be done in a timely manner by the Owner and other required agencies so as not to delay the work. The Contractor shall make any changes indicated by the Designer and Owner and resubmit the shop drawings for final approval. Approved shop drawings must be received by the Contractor before fabrication can start. Shop drawings will be reviewed for compliance with design intent only. The Contractor is responsible for all other aspects of fabrication including but not limited to engineering, procedures, installation techniques and performance, as well as coordination with sub-contractors and related trades. PRODUCT DATA The Contractor shall submit manufacturer’s technical data and installation instructions for each type of sign or fixture required for the finished and installed unit. The Contractor shall provide the Owner with complete care and maintenance instructions for the installed pieces, indicating all brand and model numbers for replaceable components that might fail including but not limited to transformers, light fixtures, motors, etc., as well as a list of all subcontractors and the replaceable materials they have provided such as flags and banners EQUIPMENT AND TRAINING Provide detailed specifications, product type and name of all equipment used in the production of the interior signage that is changeable. Train on-site signage facilities group in process and procedures for creating and updating interior signage elements. Only signage with changeable messaging will be expected to be reproduced at the facility. SAMPLES The Contractor shall submit two (2) samples of each finish color in each material, sheen, texture, and color indicated. Sample size shall be 6”x6” (150mm x 150mm) minimum. Submittal of samples shall be done to allow adjustments and resubmission without delaying to the project. Contractor may suggest substitutions if they perform better than the Designer’s requirements. Manufacturer’s product specification and performance data of the Contractor’s suggested substitutions must be submitted with the samples. LIGHT POLES Signs PID and FID are to be mounted to existing light poles in the NEXUS parking lots and on the fields. The awarded bidder shall provide written consent from the pole/light manufacturer that the proposed signage can be attached to the poles. REFERENCES Contractor shall provide case studies from three (3) recent project in addition to three (3) references. LOCATION 2600 Woodbridge Ave Edison, NJ 08837 A detailed location map can be found in Attachment D. QUALIFIERS All ideas, design arrangements, or plans indicated or represented by these drawings are owned by, and remain the sole property of Nicolson Associates. No ideas, designs, arrangements, or plans shall be disclosed to any other person, firm, or corporation for any purpose whatsoever without the express written consent of Nicolson Associates. All Artwork and Shop Drawings required under the scope of these documents are to become the sole property of the Owner at the completion of the contract, with all original or created artwork or drawings to be surrendered to the Owner at the end of fulfillment of the contract or sooner if requested in writing from the Owner. All Artwork and Drawings are not to be reproduced or circulated for use outside the scope of this contract without written consent of the Owner. Failure to comply will result in legal action to the fullest extent of the law. NOTICE TO BIDDERS NOTICE IS HEREBY GIVEN that bids shall be received electronically no later than Thursday, December 3, 2026 , at 10:00 am prevailing time, for the THE FURNISHING, DELIVERY AND INSTALLATION OF WAYFINDING SIGNS AS REQUIRED BY THE COUNTY OF MIDDLESEX. Bids shall be submitted electronically via Middlesex County's Electronic Procurement Portal https://procurement.opengov.com/portal/middlesexcountynj Legal notices issued by the County of Middlesex are available for public viewing on our Current Legal Notices webpage at https://www.middlesexcountynj.gov/government/public-notices and the official Secretary of State’s Legal Notices Website at https://www.nj.gov/state/statewide-legal-notices-list.shtml free of charge. The bid opening will be live-streamed via Zoom. Zoom meeting information can be found in the Introduction section under the Timeline (Bid Submission Deadline). Bidders are required to comply with the require
Published attachments
Addenda and notices
Addendum #1 · 1
Please use the See What Changed link to view all the changes made by this addendum.
Public questions and answers
Please advise if there are any permits required for this project.
It is the responsibility of the fabricator/installer to acquire permits if required. Many of the signs are likely to need permits.
Is there a source for electric for the LED sign? What is the scope for this sign?
Electric will be brought to within 10’ of the sign location by others. There are several LED signs. The scope for all signs is noted in the bid documents.
Are there any bonds required for the project? When does the project have to be completed by?
Bonds are not required. The project completion date is 4/22/27
Please confirm whether electrical power is already available at the signage location. If not, is the signage vendor responsible for bringing electrical power to the sign? If the vendor is responsible, please specify the distance to the nearest electrical source and identify the type of surface that would need to be trenched through (e.g., concrete, grass, asphalt, etc.).
Electric will be brought to within 10’ of the sign location by others.
Please clarify whether physical samples are required to be submitted as part of the bid submission or if they will only be required after contract award. If samples are required during the bidding phase.
Samples are required only from the company awarded the project.
Are we supposed to remove existing sigs? If yes, Kindly share the details, existing sign images, and total quantity for the signs that need to be removed?
Sign removal is not part of the bid.
On page 10 of the design intent, there is a sign type Building Identification 6 (BID6) but no reference for this on the bid form. Please advise if this sign is in the scope of the project.
Currently there are no BID6 signs in the project but we would like you to provide a unit price. This will be added to the Bid Sheet (pricing table) in an addendum shortly
Please advise if the concrete bases all have chamfered edges.
Yes
Please advise as to the dimensions of the channel letters for this sign type. There is no height given, only the length.
For height reference—from the bottom to the top of the “X” , the height is 42”