State and local · OpenGov
Turnkey Walk- In Cooler/ Freezer Combination Replacement – Southampton Elementary School
Description
The purpose of this Sealed Invitation for Bids (IFB) is to establish a firm-fixed-price turnkey contract for the emergency replacement of the walk-in cooler/freezer combination at Southampton Elementary School for Richmond Public Schools (RPS). The contractor shall furnish all labor, materials, equipment, permitting, crane service, demolition, installation, and startup required to deliver a fully operational system. The services will be provided district wide for the School Board of the City of Richmond (School Board), a public body within the Commonwealth of Virginia. The School Board of the City of Richmond does not discriminate against faith-based organizations in accordance with the Code of Virginia, § 2.24343.1 or against a bidder or offeror because of race, religion, color, sex, national origin, age, disability, or any other basis prohibited by state law relating to discrimination in employment in the performance of its procurement activity. Scope of Services Scope of Work (Turnkey Requirements) The Contractor shall provide a complete, turnkey replacement of the Walk-In Cooler/Freezer combination unit at Southampton Elementary School . "Turnkey" is defined as providing all necessary labor, materials, equipment, transportation, rigging/crane services, engineering, permits, disposal, installation, electrical/plumbing connections, refrigeration charge, testing, commissioning, and training required for a fully operational system . The baseline specification standard is a Harford/Kolpak walk-in unit or an approved equivalent . The Contractor shall be responsible for: Site Verification : Performing field measurements prior to ordering equipment to verify all interior dimensions, doorway clearances, utility locations, and slab conditions . Demolition & EPA Refrigerant Recovery : Dismantling and removing the existing walk-in box and refrigeration equipment . All existing refrigerant must be recovered and disposed of in strict accordance with EPA Section 608 guidelines and state regulations . Rigging & Crane Services : Supplying all required crane services, hoisting, staging, and rigging to safely place condensing units and structural components on site . Permitting & Code Compliance : Obtaining and paying for all required municipal building, electrical, and mechanical permits from the City of Richmond prior to commencing work . Site Protection & Cleanup : Protecting existing school finishes, floors, and surrounding kitchen equipment during installation, and removing all debris, packaging, and scrap materials daily . General & Technical Specifications The walk-in box shall be a pre-engineered, modular, panelized combination cooler/freezer designed for indoor commercial food service installation . Physical Dimensions : Outer dimensions shall strictly adhere to 13'6" W x 7'9" D x 7'6-1/4" H (or exact site-verified equivalent). Internal dimensions of the freezer compartment shall be 7’1” x 7’2”. Internal dimensions of the cooler compartment shall be 7’1" x 5’4”. NSF Certification : Entire walk-in assembly must be manufactured and listed in accordance with NSF/ANSI Standard 7 for commercial food service equipment . Structural Framing : Zero wood construction. All structural framing, perimeter rails, and corner posts must be constructed of high-density urethane or corrosion-resistant metallic framing . Insulation : Panels shall consist of 4-inch thick, CFC-free foamed-in-place polyurethane insulation with a minimum thermal resistance value of R-29 for cooler panels and R-32 for freezer panels. Panel Jointing : Panels shall lock together internally using heavy-gauge cam-action locking devices with dual neoprene gaskets to ensure air-tight seals . The access panel's existing enclosure may be reused; however, should it sustain damage during demolition, replacement panels must be provided. Finishes : Exterior walls and exposed sides: 26-gauge stucco embossed galvalume or stainless steel . Interior walls and ceiling: 26-gauge stucco embossed galvalume . Flooring : Heavy-duty smooth aluminum or stainless steel floor panels rated for a rolling weight capacity 1,000 lbs per square foot . Floor transitions shall include an NSF-certified interior/exterior transition ramp flush with the existing kitchen slab . The cooler compartment ramp shall be an interior ramp. Door, Accessories & Lighting Entrance Doors : Heavy-duty, self-closing infill doors equipped with magnetic gasket seals, heavy-duty cam-rise hinges, and adjustable hydraulic door closers . Safety Hardware : Doors must be equipped with an interior safety release latch (latch opener) allowing the door to be opened from the inside at all times, even when padlocked from the exterior . Heated Door Frames : Freezer door frames and thresholds must feature built-in, low-wattage electric anti-sweat heater wires to prevent frost accumulation and condensation . Pressure Relief Vent : The freezer compartment must include an electrically heated pressure relief valve to balance internal and external pressures during defrost cycles . Lighting & Controls : Pre-wired vapor-proof LED light fixtures yielding a minimum of 40 foot-candles at floor level, wired to an exterior digital temperature indicator switch panel with manual light override . Temperature Monitoring : Digital thermometer display with audible and visual high/low temperature alarms mounted on the exterior front wall of each compartment . Refrigeration System Specifications The refrigeration systems shall be remote split-systems designed for commercial foodservice applications operating under heavy usage . Refrigerant Standard : All systems must utilize EPA-approved, low-GWP (Global Warming Potential) next-generation refrigerant (e.g., R-454A or approved A2L/A1 equivalent meeting current SNAP rules) . Condensing Units : Factory-assembled, weather-enclosed remote condensing units equipped with scroll compressors, crankcase heaters, high/low pressure controls, head pressure controls, liquid line filter-driers, sight glasses, and suction accumulators . Evaporator Coils : Low-profile, ceiling-mounted air cooler evaporator units with rust-proof aluminum housings, EC motors, and electric defrost assemblies for freezer coils . Piping & Electrical : All interconnecting copper refrigeration lines, condensate drain lines (with insulated heat trace for freezer drain lines), and control wiring must be furnished, installed, and pressure-tested by the Contractor . Commissioning, Testing & Handover Startup & Testing : The Contractor shall perform full system vacuum evacuation, refrigerant charging, leak detection, and startup testing. Systems must be run through a complete 24-hour test period to verify holding temperatures (Cooler: 35°F to 38°F; Freezer: -10°F to 0°F) and proper defrost termination. Operations & Maintenance (O&M) Manuals : The Contractor shall provide two (2) complete binder sets and one (1) digital PDF set of installation manuals, parts lists, wiring diagrams, and warranty documents to RPS Food Services prior to final invoice approval . Staff Training : The Contractor shall provide a minimum of two (2) hours of on-site operational and maintenance instruction for RPS cafeteria managers and facilities maintenance personnel . Warranty Requirements The Contractor shall provide written manufacturer and installer warranties covering the following minimum terms from the date of final acceptance : Walk-In Panels : 10-year limited structural and panel insulation warranty . Compressors : 5-year extended compressor replacement warranty . Full Turnkey System : 2-year full system warranty covering 100% of parts, labor, freight, and travel expenses for all defects in equipment, piping, or installation workmanship . USDA & Federal Food Service Requirements Buy American Provision: In accordance with 7 CFR Part 210.21(d), the contractor must supply domestic equipment and components to the maximum extent practicable. Any non-domestic equipment must receive prior written authorization from RPS Food Services. NSF/ANSI Standard 7 Compliance: All commercial refrigeration equipment, food contact surfaces, and storage panels must be certified by NSF International or an equivalent ANSI-accredited testing laboratory. Purpose Summary The purpose of this Sealed Invitation for Bids (IFB) is to establish a firm-fixed-price turnkey contract for the emergency replacement of the walk-in cooler/freezer combination at Southampton Elementary School for Richmond Public Schools (RPS). The contractor shall furnish all labor, materials, equipment, permitting, crane service, demolition, installation, and startup required to deliver a fully operational system. The services will be provided district wide for the School Board of the City of Richmond (School Board), a public body within the Commonwealth of Virginia. The School Board of the City of Richmond does not discriminate against faith-based organizations in accordance with the Code of Virginia, § 2.24343.1 or against a bidder or offeror because of race, religion, color, sex, national origin, age, disability, or any other basis prohibited by state law relating to discrimination in employment in the performance of its procurement activity. We require an immediate quote for an emergency turnkey replacement of a walk-in cooler/freezer combination at Southampton Elementary School for Richmond Public Schools. The baseline specification standard is a Harford/Kolpak walk-in unit or an approved equivalent . Timeline Release Project Date: October 6, 2026 1st Pre-Bid Conference & Site Visit (Non-Mandatory): October 16, 2026, 10:00am 3333 Cheverly Rd, Richmond, VA 23225 2nd Pre-Bid Conference & Site Visit (Non-Mandatory): November 5, 2026, 9:00am 3333 Cheverly Rd, Richmond, VA 23225 Question Submission Deadline: November 25, 2026, 5:00pm Question Response Deadline: November 30, 2026, 5:00pm Bid Submission Deadline: December 7, 2026, 1:00pm Procurement Contact Tiffany Carey Procurement Officer Richmond , VA 23224 Email: tcarey@rvaschools.net Phone: (804) 780-6161 USDA Non-Discrimination Statement In accordance with federal civil rights law and U.S. Department of Agriculture (USDA) civil rights regulations and policies, this institution is prohibited from discriminating on the basis of race, color, national origin, sex (including gender identity and sexual orientation), disability, age, or reprisal or retaliation for prior civil rights activity . Program information may be made available in languages other than English. Persons with disabilities who require alternative means of communication to obtain program information (e.g., Braille, large print, audiotape, American Sign Language) should contact the responsible state or local agency that administers the program or USDA’s TARGET Center at (202) 720-2600 (voice and TTY) or contact USDA through the Federal Relay Service at (800) 877-8339 . To file a program discrimination complaint, a Complainant should complete a Form AD-3027, USDA Program Discrimination Complaint Form, which can be obtained online at [ https://www.usda.gov/sites/default/files/documents/USDA-OASCR%20P-Complaint-Form-0508-0002-508-11-28-17Fax2Mail.pdf ]( https://www.usda.gov/sites/default/files/documents/USDA-OASCR%20P-Complaint-Form-0508-0002-508-11-28-17Fax2Mail.pdf) , from any USDA office, by calling (866) 632-9992, or by writing a letter addressed to USDA . The letter must contain the complainant’s name, address, telephone number, and a written description of the alleged discriminatory action in sufficient detail to inform the Assistant Secretary for Civil Rights (ASCR) about the nature and date of an alleged civil rights violation . The completed AD-3027 form or letter must be submitted to USDA by: Mail: U.S. Department of Agriculture, Office of the Assistant Secretary for Civil Rights, 1400 Independence Avenue, SW, Washington, D.C. 20250-9410; or Fax: (833) 256-1665 or (202) 690-7442; or Email: program.intake@usda.gov . Richmond Public Schools is an equal opportunity provider . Bidding Instructions General Instructions In order to be considered for selection, Bidders must submit a complete response to this IFB that includes all requested elements of the bid. No other distribution of the bid shall be made by the Bidder. No bids received after the date and time specified for submission will be considered. Bids must be submitted electronically via RPS' e-Procurement Portal . No hard copies will be accepted. It is incumbent upon the Bidder to ensure its bid is received at the date, time and place specified. Richmond Public Schools is only accepting electronic submissions. Bidders shall create a FREE account with OpenGov Procurement by signing up at https://procurement.opengov.com/signup . Once you have completed account registration, browse back to this page, click on "Draft Response", and follow the instructions to submit the electronic response. No bid shall be altered or amended after the specified time for opening. Bidder’s Understanding of the Requirements Bidders are responsible for inquiring about and clarifying any requirement of this IFB that is not understood. Oral requests for information will not be accepted. All inquiries must be submitted electronically via RPS' District's e-Procurement Portal. All written inquiries must be received by RPS no later than Wednesday, November 25, 2026 by 5:00 pm . NO FURTHER INQUIRIES WILL BE ACCEPTED AFTER THIS DEADLINE. Written answers will be provided by an addendum or Question and Answer feature via RPS' e-Procurement Portal . The Offers are responsible for ascertaining the existence of any addendum In submitting a bid response to this solicitation, Bidder hereby acknowledges receipt and incorporation of any addenda issued for this Invitation for Bids. Specific Bid Instructions Bidders shall submit all required bid documentation electronically via the RPS e-Procurement Portal prior to the bid submission deadline . To be considered responsive, a complete bid submission must include the following distinct elements: Technical Submissions & Cut Sheets: Comprehensive manufacturer specification sheets, dimensioned plan and elevation drawings of the custom walk-in unit, and equipment cut sheets for all major refrigeration components (condenser, evaporator, doors, lighting, and controllers) . Project Schedule & Lead Time: Specified lead time for equipment fabrication and the total number of calendar days required from contract award to final turnkey installation and startup . Warranty Documentation: Written confirmation and commercial warranty documentation satisfying the minimum project requirements (10-year panel warranty, 5-year compressor warranty, and 2-year full system parts and labor warranty) . Buy American Provision Where applicable, contractor shall comply with the Buy American Provision for Child Nutrition Program procurements (7 CFR Part 210.21(d) and 7 CFR Part 220.16) . The Contractor shall purchase, to the maximum extent practicable, domestic commodities or products . A "domestic commodity or product" is defined as an agricultural commodity produced in the United States and a food product processed in the United States substantially using agricultural commodities produced in the United States . For equipment, major components, and manufactured items supplied under this contract, domestic end products shall be utilized . Exceptions to the Buy American Provision may be approved only upon prior written authorization from RPS Food Services and must be documented based on one of the following criteria : The product or component is not produced or manufactured in the U.S. in sufficient and reasonably available quantities of a satisfactory quality ; or Competitive bids establish that the costs of a U.S. product are significantly higher than the non-domestic product . The Contractor must retain all documentation supporting any approved exception for review during federal administrative audits . Bid Opening The public bid opening will be held virtually by RPS and will begin approximately 5 minutes after the scheduled Bid Submission Deadline: 1:00 pm on Monday, December 7, 2026 . More details and a link to the meeting can be found below: IFB 26-7167-10: Bid Opening Friday, November 6 · 1:00 – 1:30pm Time zone: America/New_York Google Meet joining info Video call link: https://meet.google.com/mvi-txxi-iha Or dial: (US) +1 385-262-3859 PIN: 154 650 946# More phone numbers: https://tel.meet/mvi-txxi-iha?pin=3112733675413 Virginia Public Procurement Act (VPPA) & SCC Registration In accordance with the Virginia Public Procurement Act (VPPA) and Code of Virginia § 2.2-4311.2, all bidders must be registered and authorized to transact business in the Commonwealth of Virginia as a domestic or foreign business entity with the Virginia State Corporation Commission (SCC), if so required by law . Bidders shall include their SCC Identification Number with their proposal . Any bidder that is not required to be authorized to transact business in the Commonwealth as a foreign business entity under Title 13.1 or Title 50 or as otherwise provided by law shall include in its bid a statement describing why the bidder is not required to be so authorized . Debarment and Suspension Status (2 CFR Part 180) This procurement is a covered transaction for purposes of 2 CFR Part 180 and 2 CFR Part 417 . By submitting a bid, the bidder certifies that neither the firm, its principals (officers, directors, owners), nor its key affiliates are presently debarred, suspended, proposed for debarment, declared ineligible, or voluntarily excluded from participation in this transaction by any federal department or agency . Required Action: Bidders must complete Vendor Questionnaire portion. Byrd Anti-Lobbying Disclosure (31 U.S.C. 1352) Bidders applying or bidding for an award exceeding $100,000 must file the required lobbying certification . Each tier certifies to the tier above that it will not and has not used federally-appropriated funds to pay any person or organization for influencing or attempting to influence an officer or employee of any agency, a member of Congress, an officer or employee of Congress, or an employee of a member of Congress in connection with obtaining any federal contract, grant, or other award covered by 31 U.S.C. 1352 . Required Action: Bidders must complete, sign, and upload Attachment B: Disclosure of Lobbying Activities (SF-LLL) into OpenGov . If no lobbying activities have taken place, the bidder must check "N/A" on the form, sign, and submit . Crimes Against Children Certification In accordance with Code of Virginia § 22.1-296.1, prior to awarding a contract for the provision of services that require direct contact with students or work on school grounds during regular school hours, Richmond Public Schools requires the contracting entity to certify that no individual who will provide such services or installation labor on school property has been convicted of a felony or any offense involving the sexual molestation, physical abuse, or sexual abuse of a child . Required Action: Bidders must complete Vendor Questionnaire portion. Submission Requirements Checklist To be considered responsive, Bidders must complete and submit all required sections and documentation directly within the OpenGov portal prior to the bid closing : OpenGov Vendor Questionnaire & Electronic Certifications : Complete all mandatory fields within the portal's Vendor Questionnaire . This single integrated questionnaire captures all required state and federal certifications , including: Virginia State Corporation Commission (SCC) Registration Number . Buy American Provision Certification & Exception Request (if applicable) . Certification Regarding Debarment, Suspension, Ineligibility, and Voluntary Exclusion (2 CFR Part 180) . Disclosure of Lobbying Activities Statement (Byrd Anti-Lobbying Amen
Published attachments
Addenda and notices
Addendum #1 · 1
Event: Second Optional Site Visit Date: November 5, 2026 Time: 9:00am-10:00am (ET) Location: 3333 Cheverly Rd, Richmond VA 23225 Please Note: Attendance at this site visit is completely optional and is not a prerequisite for submitting a bid.
Addendum #2 · 2
See changes made to General & Technical Specifications, Section 2.2. All bids are now due no later than 1:00 PM (EST) on Monday, December 7, 2026 , and must be submitted electronically through the RPS OpenGov portal. No other bid formats or submission methods will be accepted. Please use the See What Changed link to view all the changes made by this addendum.
Public questions and answers
Good morning, Are there any drawings for this job?
Hello. No drawings have been created for this project.
Good morning. Will the labor requirement be non-union, prevailing wage or union? Also, I gather the refrigeration condensers will be roof mounted. Would you be able to provide an approximate distance from the walk-in box to the condenser location?
There is no union or prevailing wage requirement on this project. It is a furnish and install of equipment project, not a construction project.
Will the cooler and freezer be divided equally in size? Do you want two outer doors, or do you want a walk-thru? (Enter from outer door and then walk thru to the freezer from inside the cooler)
See addendum #2 for dimensions.
OpenGov categories
- 04566 · Refrigerators and Freezers
- 74066 · Refrigeration Units (For Vaults and Walk-In Coolers), Complete and Self-Contained
- 74070 · Refrigerators and Freezers, Commercial
- 90618 · Cold Storage; Refrigeration; Fast Freeze - Architectural
- 92520 · Cold Storage; Refrigeration; Fast Freeze/Engineering
- 93667 · Refrigeration Equipment Maintenance and Repair